Introduction to Heat Transfer
6th Edition
ISBN: 9780470501962
Author: Frank P. Incropera, David P. DeWitt, Theodore L. Bergman, Adrienne S. Lavine
Publisher: Wiley, John & Sons, Incorporated
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 4, Problem 4.14P
Two parallel pipelines spaced 0.5 m apart are buried insoil having a thermal conductivity of
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
In a thermal power plant, a horizontal copper pipe of "D" diameter, "L" length and thickness 1.9 cm enters into the boiler that has the thermal conductivity as 0.37 W/mK. The boiler is maintained at 102 °C and temperature of the water that flows inside the pipe is at 34°C. If the energy transfer (Q) is 100735 kJ in 7 hours. Determine the Heat transfer rate, Surface area of the pipe and Diameter & Length of the pipe, if D = 0.015 L .
In a thermal power plant, a horizontal copper pipe of "D" diameter, "L" length and thickness 1.2 cm enters into the boiler that has the thermal conductivity as 0.37 W/mK. The boiler is maintained at 113C and temperature of the water that flows inside the pipe is at 29C. If the energy transfer (Q) is 118779 kJ in 7 hours.
Calculate:
4-Length of the pipe, if D = 0.017 L.
5-Pipe Diameter (in mm)
A 10 ft length of pipe with an inner radius of 1 in and outer radius of 1.25 in has an outer surface temperature of 250 F. The heat transfer rate is 30,000 BTU/hr. Find the interior surface temperature. Assume k = 25 BTU/hr-ft-F.
Chapter 4 Solutions
Introduction to Heat Transfer
Ch. 4 - In the method of separation of variables (Section...Ch. 4 - A two-dimensional rectangular plate is subjected...Ch. 4 - Consider the two-dimensional rectangular plate...Ch. 4 - A two-dimensional rectangular plate is subjected...Ch. 4 - Prob. 4.5PCh. 4 - Prob. 4.6PCh. 4 - Free convection heat transfer is sometimes...Ch. 4 - Prob. 4.8PCh. 4 - Radioactive wastes are temporarily stored in a...Ch. 4 - Based on the dimensionless conduction heat rates...
Ch. 4 - Prob. 4.11PCh. 4 - A two-dimensional object is subjected to...Ch. 4 - Prob. 4.13PCh. 4 - Two parallel pipelines spaced 0.5 m apart are...Ch. 4 - A small water droplet of diameter D=100m and...Ch. 4 - Prob. 4.16PCh. 4 - Pressurized steam at 450 K flows through a long,...Ch. 4 - Prob. 4.19PCh. 4 - A furnace of cubical shape, with external...Ch. 4 - Prob. 4.21PCh. 4 - Prob. 4.22PCh. 4 - A pipeline, used for the transport of crude oil,...Ch. 4 - A long power transmission cable is buried at a...Ch. 4 - Prob. 4.25PCh. 4 - A cubical glass melting furnace has exterior...Ch. 4 - Prob. 4.27PCh. 4 - An aluminum heat sink k=240W/mK, used to coolan...Ch. 4 - Hot water is transported from a cogeneration power...Ch. 4 - Prob. 4.30PCh. 4 - Prob. 4.31PCh. 4 - Prob. 4.32PCh. 4 - An igloo is built in the shape of a hemisphere,...Ch. 4 - Consider the thin integrated circuit (chip) of...Ch. 4 - Prob. 4.35PCh. 4 - The elemental unit of an air heater consists of a...Ch. 4 - Prob. 4.37PCh. 4 - Prob. 4.38PCh. 4 - Prob. 4.39PCh. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Determine expressions for...Ch. 4 - Prob. 4.43PCh. 4 - Prob. 4.44PCh. 4 - Prob. 4.45PCh. 4 - Derive the nodal finite-difference equations for...Ch. 4 - Prob. 4.47PCh. 4 - Prob. 4.48PCh. 4 - Consider a one-dimensional fin of uniform...Ch. 4 - Prob. 4.50PCh. 4 - Prob. 4.52PCh. 4 - Prob. 4.53PCh. 4 - Prob. 4.54PCh. 4 - Prob. 4.55PCh. 4 - Prob. 4.56PCh. 4 - Steady-state temperatures at selected nodal points...Ch. 4 - Prob. 4.58PCh. 4 - Prob. 4.60PCh. 4 - The steady-state temperatures C associated with...Ch. 4 - A steady-state, finite-difference analysis has...Ch. 4 - Prob. 4.64PCh. 4 - Consider a long bar of square cross section (0.8 m...Ch. 4 - Prob. 4.66PCh. 4 - Prob. 4.67PCh. 4 - Prob. 4.68PCh. 4 - Prob. 4.69PCh. 4 - Consider Problem 4.69. An engineer desires to...Ch. 4 - Consider using the experimental methodology of...Ch. 4 - Prob. 4.72PCh. 4 - Prob. 4.73PCh. 4 - Prob. 4.74PCh. 4 - Prob. 4.75PCh. 4 - Prob. 4.76PCh. 4 - Prob. 4.77PCh. 4 - Prob. 4.78PCh. 4 - Prob. 4.79PCh. 4 - Prob. 4.80PCh. 4 - Spheres A and B arc initially at 800 K, and they...Ch. 4 - Spheres of 40-mm diameter heated to a uniform...Ch. 4 - To determine which parts of a spiders brain are...Ch. 4 - Prob. 4.84P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A 10-mm-inner-diameter pipe made of commercial steel is used to heat a liquid in an industrial process. The liquid enters the pipe with Ti=25°C, V=0.8 m/s. A uniform heat flux is maintained by an electric resistance heater wrapped arounf the outer surface of the pipe, so that the fluid exits at 75°C. Assuming fully developed flow and taking the average fluid properties to be ρ=1000 kg/m3, cp=4000 J/kg·K, µ=2x10-3 kg/m·s, k=0.48 W/m·K, and Pr=10, determine: The required surface heat flux , produced by the heater The surface temperature at the exit, Ts The pressure loss through the piper and the minimum power required to overcome the resistance to flow.arrow_forwardAn incompressible fluid flows through a rectangular cross section duct, with width much larger than height of the cross section. The duct surface is heated at a uniform rate along its length. If the centreline of the flow is along the centre of the duct where y = 0, the distance from the centreline to the surface of the duct is b = 25 mm, and the thermal conductivity of the fluid is 0.6 W/mK, what is the local heat transfer coefficient in the developed region of the flow? Give your answer in W/m2K to 1 decimal place. I AM POSTIING THIS AGAIN. PLEASE STOP ? COPY FROM INTERNET AND SEND RANDOM SOLUTION. HINT THE FINAL ANSWER IS 38.4 But i need step by step solution. if you don't get this value don't send it please, reject and add the creditarrow_forwardAn incompressible fluid flows through a rectangular cross section duct, with width much larger than height of the cross section. The duct surface is heated at a uniform rate along its length. If the centreline of the flow is along the centre of the duct where y = 0, the distance from the centreline to the surface of the duct is b = 25 mm, and the thermal conductivity of the fluid is 0.6 W/mK, what is the local heat transfer coefficient in the developed region of the flow? Give your answer in W/m2K to 1 decimal place.arrow_forward
- In a thermal power plant, a horizontal copper pipe of "D" diameter, "L" length and thickness 0.6 cm enters into the boiler that has the thermal conductivity as 0.33 W/mK. The boiler is maintained at 105C and temperature of the water that flows inside the pipe is at 28C. If the energy transfer (Q) is 118922 kJ in 6 hours. Determine the Heat transfer rate, Surface area of the pipe and Diameter & Length of the pipe, if D = 0.016 L. Change in Temperature (in K) = Heat Transfer Rate (in W) = Surface Area of the Pipe (m2) =arrow_forwardHeat Transfer with a Liquid Metal. The liquid metal bismuth at a flow rate of 2.00 kg/s enters a tube having an inside diameter of 35 mm at 425°C and is heated to 430°C in the tube. The tube wall is maintained at a temperature of 25°C above the liquid bulk temperature. Calculate the tube length required. The physical properties are as follows (H1): k = 15.6 W/m K, c,=149 J/kg K, u = 1.34 x 10-3 Pa s.arrow_forwardSteam at 350 °C flows through the stainless steel pipe with k=26 W/m.°C. The inner and outer diameters of the stainless steel pipe are 6.0 cm and 7.0 cm, respectively. The pipe is insulated from the outside with a 4.0 cm thick glass wool (k= 0.038 W/m.°C) and then a 3.0 cm thick k=0.25 W/m.K material. The insulated pipe is in the environment at 20 °C. The heat loss from the pipe occurs only by [natural convection+radiation]. Film heat transfer coefficient including the effects of [natural convection+radiation] in the insulated pipe is 30 W/m². is C. Calculate the heat transferred per unit pipe length since the film heat transfer coefficient defined according to the inner area of the pipe is 110 W/m².°C.arrow_forward
- In a thermal power plant, a vertical copper pipe of "D" diameter, "H" height and thickness 1 cm enters into the boiler that has the thermal conductivity as 0.35 W/mK. The boiler is maintained at 102C and temperature of the water that flows inside the pipe is at 25C. If the energy transfer (Q) is 119031 kJ in 7 hours. Determine the Heat transfer rate, Surface area of the pipe and Diameter & Height of the pipe, if H = 27 D.arrow_forwardProblem 3: Insulation To=1 Toowwww Steam Tx2 T₂ T3 www www R₁ R₁ R₂ www.T R₂ Steam at Tx1 = 320 °C flows in a cast iron pipe (k = 80 W/m. °C) whose inner and outer diameters are 5 cm = 0.05 m and D₂ = 5.5 cm = 0.055 m, respectively. The pipe is covered with 3-cm-thick glass wool insulation with k = 0.05 W/m. °C. Heat is lost to surroundings at T2 = 5 °C by natural convection and radiation, with a combined heat transfer coefficient of h₂ = 18 W/m². °C. Taking the heat transfer coefficient inside the pipe to be h₁ = 60 W/m². °C, determine the temperature drops across the pipe and the insulation. The determination is based on a unit length of the pipe (L = 1 m). Assumptions 1. Heat transfer is one-dimensional since there is no indication of any change with time. 2. Heat transfer is one-dimensional since there is thermal symmetry about the centreline and no variation in the axial direction. 3. Thermal conductivities are constant. 4. The thermal contact resistant at the interface is…arrow_forwardExample: A light oil with 20°C inlet temperature flows at a rate of 500 kg / min through 5 cm ID pipe which is enclosed by a jacket containing condensing steam at 150°C. If the pipe is 10 cm long, find the outlet temperature of the oil. Take the following oil properties of oil at 85°C: v = 3.6 x 10-6 m²/sec k = 0.12 W/m. K p = 880 kg/m³ Cp = 2100 J/kg. Karrow_forward
- Consider a copper tube with domestic hot water flowing inside (Tin =70◦C, um = 0.5m/s). The inner diameter of the tube is Din=13mm and outer diameter is Dout=15mm. The tube is located in a crawlspace and the surrounding temperature is T∞ =0 ◦C. The inner and outer heat transfer coefficients are hin = 250W/m2K and hout = 5W/m2K. The tube is insulated at the outer surface with insulating foam of thickness lf oam=17.5mm. The temperature drop of the water along the tube is 0.5◦C. 1. Draw a sketch that indicates the dimensions of the system, and the directions of heat transfer and fluid flow. 2. What is the length of the tube?arrow_forwardAnswer this ASAP The diameter of the tube is 25 mm. The specific heat of water is 4.18 kJ/kg.°C. The overall heat transfer coefficient is 0.7 kW/m².°C. 1. Schematic of temperature distribution 2.ΔTLMTD 3.Actual heat transfer rate 4.Cmin 5.Maximum heat transfer ratearrow_forwardWater enters a tube at 29°C with a flow rate of 460 kg/h. The rate of heat transfer from the tube wall to the fluid is given as qs′(W/m)=ax, where the coefficient a is 25 W/m2 and x(m) is the axial distance from the tube entrance. (a) Beginning with a properly defined differential control volume in the tube, derive an expression for the temperature distribution Tm(x) of the water. (b) What is the outlet temperature of the water for a heated section 31 m long? (c) Sketch the mean fluid temperature, Tm(x), and the tube wall temperature, Ts(x), as a function of distance along the tube for fully developed and developing flow conditions. (d) What value of a uniform wall heat flux, qs″ (instead of qs′=ax), would provide the same fluid outlet temperature as that determined in part 8.13b? For this type of heating, sketch the temperature distributions requested in part 8.13c.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Heat Transfer – Conduction, Convection and Radiation; Author: NG Science;https://www.youtube.com/watch?v=Me60Ti0E_rY;License: Standard youtube license