Chapter 4, Problem 4.35P
To determine
(a)
Line to neutral capacitance per phase in F/km and admittance to neutral in S/km.
Compare the results with the case in which the phase spacing is 4ft.
To determine
(b)
Line to neutral capacitance per phase in F/km and admittance to neutral in S/km.
Compare the results with the case in which the phase spacing is 4ft.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
please explain the operating principle of single phase 2S-2P PMSM based on 3D design illustration.
Q4
(a)
(b)
A 4-bus power system, as shown in Figure Q4a, of which the parameters are
given in Table Q4a; the p.u. value of every component is given based on its
own base values (rating).
i)
Draw an impedance diagram of the network, showing all impedances
in p.u., on 1000 MVA and 20 kV base values in the Generator G3
zone.
A three-phase short circuit occurs at busbar 3 through a rearance of
j0.12 p.u., where the pre-fault voltage is 525 kV and the pre-fault
current is neglected. Calculate the short circuit current in p.u. using
Thevenin's Theorem.
Describe the data required for each component of a typical power network
when analysing faults, and the reasons for needing each item of data.
T, bus 1
∞to
ΔΥ
G₁
G₂
G3
T₁
T₂
Тз
Transmission line:
150 Ω
bus 4
T₂
bus 2
150 Ω
150 Ω
G₂
YE
bus 3 T₂
머(
YEA
Figure 04a
500 MVA, 13.8 kV, XG1= 0.20 p.u.
750 MVA, 18 kV, XG2 = 0.18 p.u.
1000 MVA, 20 kV, XG3 = 0.17 p.u.
500MVA, 13.8 (A) /500 kV, XT1 = 0.12 p.u.
750 MVA, 18 (A) /500 kV, XT2 = 0.10 p.u.
1000…
in distribution transformers; What is 30 degrees phase shift in delta-star connection? What are the disadvantages? (can you explain with drawing?)
Chapter 4 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A network consisting of a set of generator and load buses is to be modeled with a DC power flow, for the sake of conducting a contingency analysis. The initial flows calculated with the DC power flow give the following information: f°2-4 = - 65.3 MW and fº4-5 = 13.6 MW. The following values of LODF and PTDF factors are given: PTDF54,2-4 = -0.2609, LODF2-4,4-5 = -0.6087. Calculate the contingency flow on line 2-4 due to outage of line 4-5. Select one: O a. -75.5MW O b. None of these O c. -68.85MW O d. -73.58MW O e. 75.5MW O f. -61.75MWarrow_forwardWhat is load curvearrow_forwardobtain the closed loop troosfer function for the system below?arrow_forward
- What are FACTS (Flexible Alternating Current Transmission Systems), and how do they enhance power system performance and control?arrow_forwardIn the T-Model method which among these are divided into two halves. a. Both (A) and (B) b. None of these c. Shunt capacitance d. Series impedancearrow_forwardWhat are FACTS (Flexible Alternating Current Transmission Systems) devices, and how do they enhance the control and stability of power systems?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning