Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 4, Problem 4.46P
To determine
(a)
Capacitive reactance-to-neutral per phase and the capacitive reactance of the line in ohm per phase.
To determine
(b)
Capacitive reactance-to-neutral per phase and the capacitive reactance of the line in ohm per phase.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A single-phase transmission line consisting
of two conductors, the radius of each
conductor is 0.4 cm, the distance between
the conductors is three and half meters and
the height above ground is eight
1-The capacitance in uF/km without effect
of ground is 2-The capacitance in pF/km
with effect of ground is
A single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight meter. Determine
1)The capacitance in uF/km without effect of ground
2)The capacitance in uF/km with effect of ground
A Three-phase transposed line is composed of one conductor per phase with flat horizontal spacing of D = 14 meters, as shown in the below figure. The conductors have a diameter of 2.6 cm and
a GMR of 1.012 cm. Find the capacitance per phase per kilometer of the line.
a
C
D
D
2D
Select one:
O a 0.0088 microF/Km
Ob. 0.0077 microF/Km
Oc 1.455 microF/Km
Od. None of these
Chapter 4 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Similar questions
- In terms of line-to-line capacitance, the line-to-neutral capacitance of a single-phase transmission line is Same Twice One-halfarrow_forwardThe affect of the earth plane is to slightly increase the capacitance, and as the line height increases, the effect of earth becomes negligible. True Falsearrow_forwardA 60-Hz, single-phase two-wire overhead line has solid cylindrical copper conductors with a 1.5 cm diameter. The conductors are arranged in a horizontal configuration with 0.5 m spacing. Calculate in mH/km (a) the inductance of each conductor due to internal flux linkages only, (b) the inductance of each conductor due to both internal and external flux linkages, and (c) the total inductance of the line.arrow_forward
- A three-phase transposed line is composed of one ACSR Bobolink conductor per phase with a horizontal spacing of 11 meters as shown in the figure. phase with a horizontal spacing of 11 meters as shown in the figure. The conductors have a diameter of 3.625 cm and a RMG of 1.439 cm. Calculate the inductance and capacitance to the neutral of the line.arrow_forwardOne circuit of a single-phase transmission line is composed of three solid 0.12" radius wires. The return circuit is composed of two 0.15" radius wires. Find the inductance of the complete line in mH/mi. The distance between wires are 40" horizontally and 25" vertically. A. 2.54 mH/mi B. 2.478 mH/mi C. 2.488 mH/mi D. 2.567 mH/mi Provide Clear Explainationarrow_forwardCould you solve this?!arrow_forward
- Subject Power Transmission line and Distribution.arrow_forwardA three phase transmission line has horizontal configuration with a spacing of 6 meters between adjacent conductors and 12 meters between outer conductors. The radius of each conductors is 1.81 centimeters. The value inductive reactance for 1 kilometer is: a. 1.579 Ohms b. 0.789 Ohms c. 2.579 Ohms d. 3.579 Ohmsarrow_forwardI need the answer as soon as possiblearrow_forward
- A 3-phase 80 km long single circuit 66 kV transposed overhead line has horizontal spacing with 5 m between adjacent conductors and 6 m between outer conductors. The conductor diameter is 2.5 cm. Find the Inductance per phasearrow_forwardQ1. Figure 1 shows the conductor configuration of a completely transposed three-phase overhead transmission line with bundled phase conductors. All conductors have a radius of 0.74 cm with a 30 cm bundle spacing. a) Determine the inductance per phase in mH/km b) Find the inductive line reactance per phase in 22/mi at 60 Hz. c) Determine the line to neutral capacitance per phase in µF/km A B -30 cm -30 cm 6 m 6m Figure 1: Conductor configuration. 30 cmarrow_forward2m 2m 1.8m 1.7m e) The diagram above shows the spacing of a 66 kV, 50 Hz, 3-phase line which is mounted on wooden poles. The radius of each conductor is 25mm and Eo is 8.854x1012 F/m. Calculate: (i) Find the average capacitance between each phase and neutral. (ii) The associated capacitive reactance for: of line. Paper Ma2021arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning