Find the inductive reactance per mile of a single-phase overhead transmission line operating at 60 Hz given the conductors to be Partridge and the spacing between centers to be 30 ft.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
I need the answer as soon as possible
A double-circuit
its capacitance to neutral per mile.
line is shown below. The conductor radius is 0.0452 ft. Determine
16'
16'
a
b
22'
c'
b'
a'
2.5 A 3-phase single circuit bundled conductor line with two sub-conductors per phase has horizontal
spacing with 6.1 m between the centre lines of adjacent phases. The distance between the sub-
conductors of each phase is 30.5 cm and each sub-conductor has a diameter of 2.54 cm. Find the
inductance per phase per km.
[0.988 mH]
Chapter 4 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Shield wires located above the phase conductors protect the phase conductors against lightning. True Falsearrow_forwardFind the inductive reactance per mile of a single-phase line operating at 50 Hz. The conductor has a GMR of D, 0.0217 ft, and spacing GMD is 15 ft between centers. O 0.41 O 0.66 O 0.79 O 0.49arrow_forwardSubject Power Transmission line and Distribution.arrow_forward
- 12. There are 6 conductors in a double circuit line. Each conductor has a radius of 12 mm. The 6conductors are arranged horizontally. The center to center distance between the conductor is 2m. The sequence of conductors are from left to right as follows: a,b.c,a', b', c'. Calculate the inductance per km per phase of system. the a' 2 m 2 m 2 m 2 m 2 marrow_forwardanswer it i will ratearrow_forwardFind the inductive reactance per phase in ohms per mile, and the capacitativereactance to neutral in ohm-miles for a three-phase line that has three equilaterallyspaced conductors of ACSR Dove. The conductors are 10 feet apart, and the operating frequency is 60 Hz. The GMR of the Dove conductor is r0 = 0.0313 feet andthe radius of the Dove conductor is r = 0.4635 inches. (GMR stands for geometricmean radius and r0is the equivalent radius that is adjusted to account for the fluxlinked inside the wire in inductance calculations.arrow_forward
- Three conductors of a 3-phase overhead line are arranged in a horizontal plane 6 m apart. The diameter of each conductor is 1·24 cm. Find the capacitance of each conductor to neutral per 100 km of the line.arrow_forwardPlease provide Handwritten answerarrow_forwardA three-phase 60-Hz transmission line has its conductors arranged in a triangular formationso that two of the distances between conductors are 25 ft. and the third distance is 42 ft.The conductors are ACSR Osprey. Determine the inductance and inductive reactance perphase per mile.arrow_forward
- Derive the equation of Capacitance per phase for the 3-phase double circuit line with hexagonal spacing. (transposition of conductors is not required)arrow_forwardCalculate the capacitance per km per phase for a 3 phase, 50Hz, double circuit line shown in figure below. Each conductor has a diameter of 25mm and subconductor spacing 0,3m. the line is completely transposed. 0.3m 6 m 6marrow_forwardA three phase system with Dab Dbc one conductor per phase as shown in the figure. The conductors are stranded and spaced as shown, (Dab=Dbc=4m). The outside diameter of the phase conductor is 2cm. The GMR of the phase conductor is 0.7788 cm. The value of inductance per phase is: Select one: O a. (1.2445 * 10A-3) mH/km O b. (1.1559 * 10^-6) H/m O c. (1.4562 * 10A-6) H/m O d. (1.2945 * 10A-6) H/m O e. (1.2445 * 10A-6) H/marrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Series compensation of long transmission lines; Author: Georg Schett;https://www.youtube.com/watch?v=smOqSxFBvVU;License: Standard Youtube License