Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 4, Problem 4.18P
A 230-kV, 60-Hz, three-phase completely transposed overhead line has one ACSR 954 kcmil conductor per phase and flat horizontal phase spacing, with 7 m between adjacent conductors Determine the inductance in H/m and the inductive reactance in
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
I need the answer as soon as possible
2.5 A 3-phase single circuit bundled conductor line with two sub-conductors per phase has horizontal
spacing with 6.1 m between the centre lines of adjacent phases. The distance between the sub-
conductors of each phase is 30.5 cm and each sub-conductor has a diameter of 2.54 cm. Find the
inductance per phase per km.
[0.988 mH]
Calculate the capacitance per km per phase for a 3 phase, 50Hz, double circuit line
shown in figure below. Each conductor has a diameter of 25mm and subconductor
spacing 0,3m. the line is completely transposed.
0.3m
6 m
6m
Chapter 4 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A 3-phase 80 km long single circuit 66 kV transposed overhead line has horizontal spacing with 5 m between adjacent conductors and 6 m between outer conductors. The conductor diameter is 2.5 cm. Find the Inductance per phasearrow_forwardDerive the equation of Capacitance per phase for the 3-phase double circuit line with hexagonal spacing. (transposition of conductors is not required)arrow_forward3-phase single circuit bundled conductor line with two sub-conductors per phase has horizontalspacing with 6.1 m between the centre lines of adjacent phases. The distance between the subconductorsof each phase is 30.5 cm and each sub-conductor has a diameter of 2.54 cm. Find theinductance per phase per km. [0.988 mh]arrow_forward
- A three phase system with Dab Dbc one conductor per phase as shown in the figure. The conductors are stranded and spaced as shown, (Dab=Dbc=4m). The outside diameter of the phase conductor is 2cm. The GMR of the phase conductor is 0.7788 cm. The value of inductance per phase is: Select one: O a. (1.2445 * 10A-3) mH/km O b. (1.1559 * 10^-6) H/m O c. (1.4562 * 10A-6) H/m O d. (1.2945 * 10A-6) H/m O e. (1.2445 * 10A-6) H/marrow_forwardConsider the 500 kV, three phase bundled conductor line as shown in the figure below. Find the line to neutral capacitance. 0.5 m 30 mm (0) (O to Ine 15 m 15 marrow_forwardA three-phase transposed line is composed of one ACSR Bobolink conductor per phase with a horizontal spacing of 11 meters as shown in the figure. phase with a horizontal spacing of 11 meters as shown in the figure. The conductors have a diameter of 3.625 cm and a RMG of 1.439 cm. Calculate the inductance and capacitance to the neutral of the line.arrow_forward
- Solve this 2 problem in detailarrow_forwardA 3-phase 50 km long single circuit 66 kV transposed overhead line has horizontal spacing with3 m between adjacent-conductors and 6 m between outer conductors. The conductor diameter is2 cm. Find the Inductance per phase. [61.85 mh]arrow_forwardFind the inductive reactance per mile of a single-phase line operating at 50 Hz. The conductor has a GMR of D, 0.0217 ft, and spacing GMD is 15 ft between centers. O 0.41 O 0.66 O 0.79 O 0.49arrow_forward
- A transposed three-phase double circuit transmission line configuration is shown in Figure 2. The radius of each conductor is 2 cm. Determine; i) the inductance per kilometer ii) the capacitance per kilometer 7.5m 0.75m 4m b K- b' 4m Figure 2arrow_forward(a) A three phase transposed transmission tower comprises of three-bundled conductor and double-circuit configured in vertical position as shown in Figure 2. Each sub-conductor in each circuit and each phase is an ACSR type, size 477,000 cmil and stranding 26/7. Given the GMR of each sub-conductor is 0.8809 cm and diameter is 2.1793 cm, analyze: i. Inductance in mH/km ii. Capacitance in µF/km 0.75m 7.5m b' 4m 4m 45cm Figure 2arrow_forwardA 10 km long three phase line having a diameter of 2.5 mm conductors is arranged symmetrically with a spacing of 2 m. So find the inductance per phase and capacitance per phase.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License