Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 4, Problem 4.19P
To determine
(a)
Inductance in henry per meter and Inductive reactance in ohms per kilometer.
Compare the results with the case when the phase spacing is 7m.
To determine
(b)
Inductance in henry per meter and Inductive reactance in ohms per kilometer.
Compare the results with the case when the phase spacing is 7m.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A three phase, 11 KV, underground cable system, consider a single core of conductor radius 0.5 cm diameter and lead sheath of 1.25 cm. The core and lead sheath have been separated by two intersheaths with radius 0.75 cm and 1 cm. Draw the cable core, dielectric and intersheath layers showing the thickness of each layer, then determine the voltages on the both intersheaths. Suppose the maximum stress on the layers are the same.
12. There are 6 conductors in a double circuit
line. Each conductor has a radius of 12 mm.
The 6conductors are arranged horizontally.
The center to center distance between the
conductor is 2m. The sequence of conductors
are from left to right as follows: a,b.c,a', b', c'.
Calculate the inductance per km per phase of
system.
the
a'
2 m
2 m
2 m
2 m
2 m
GMR calculate
Chapter 4 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A three phase, 33 KV, underground cable system, consider a single core of conductor radius 0.8 cm diameter and lead sheath of 2.3 cm. The core and lead sheath have been separated by two intersheaths with radius 1.3 cm and 1.8 cm. Draw the cable core, dielectric and intersheath layers showing the thickness of each layer, then determine the voltages on the both intersheaths. Suppose the maximum stress on the layers are the same. Please i need it know pleasearrow_forwardA 30 kV single core cable has a conductor dimeter of 2 cm and a sheath of inside diameter 6 cm. Find the maximum (peak value) and minimum stress (peak value) in the insulation.arrow_forwardQ4(a) The differences between TWO unequal towers 60 m support a transmission line conductor at road crossing. The given span length is 499.5 m as show in Figure Q4(a). If the tension in the conductor is 1700 kg, determine the minimum clearance of the conductor and road and clearance mid-way between the supports. Weight of conductor is 1-5 kg/m. Bases of the towers can be considered to be at road level. Given height of the tower A is 35 m from the ground level. Span Length= 499.5 ROAD Figure Q4(a)arrow_forward
- Derive the equation of Capacitance per phase for the 3-phase double circuit line with hexagonal spacing. (transposition of conductors is not required)arrow_forward2.5 A 3-phase single circuit bundled conductor line with two sub-conductors per phase has horizontal spacing with 6.1 m between the centre lines of adjacent phases. The distance between the sub- conductors of each phase is 30.5 cm and each sub-conductor has a diameter of 2.54 cm. Find the inductance per phase per km. [0.988 mH]arrow_forwardSome electricians do not bother to calculate the minimum size of neutral service conductor. They size the minimum ungrounded conductor size and then use this information to determine the minimum neutral conductor size. Explain how they determine the minimum neutral size using the minimum ungrounded conductor sizarrow_forward
- The Aluminum Electrical Conductor Handbook lists a dc resistance of 0.01558 ohm per 1000 ft at 20C and a 60-Hz resistance of 0.0956 ohm per mile at 50C for the all-aluminum Marigold conductor, which has 61 strands and whose size is 1113 kcmil. Assuming an increase in resistance of 2 for spiraling, calculate and verify the dc resistance. Then calculate the dc resistance at 50C, and determine the percentage increase due to skin effect.arrow_forwardConductor spacings, types, and sizes do have an impact on the series impedance and shunt admittance. True Falsearrow_forwardFor the case of double-circuit, bundle-conductor lines, the same method indicated in Problem 4.27 applies with r' replaced by the bundles GMR in the calculation of the overall GMR. Now consider a double-circuit configuration shown in Figure 4.36 that belongs to a 500-kV, three-phase line with bundle conductors of three subconductors at 21 in. spacing. The GMR of each subconductor is given to be 0.0485 ft. Determine the inductive reactance of the line in ohms per mile per phase. You may use XL=0.2794logGMDGMR/mi/phasearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License