Rework Problem 4.20 if the bundled line has (a) three ACSR, 1351 kcmil conductors per phase or (b) three ACSR, 900 kcmil conductors per phase, without changing the bundle spacing or the phase spacings between bundle centers. Compare the results with those of Problem 4.20.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
4.18 A 230-kV, 60-Hz, three-phase completely transposed overhead line has
one ACSR 954 kcmil conductor per phase and flat horizontal phase spac-
ing, with 7 m between adjacent conductors. Determine the inductance in
H/m and the inductive reactance in Q/km.
The equivalent circuit of a single phase short transmission line is shown
in Figure Q4 (b). Here, the total line resistance and inductance are
shown as lumped instead of being distributed.
i) Sketch the phasor diagram and assess with by labeling the details for
the A.C. series circuit shown in Figure Q4 (b) for the lagging power factor
at load point (Vn).
ii) Summarize, the impact of voltage regulation and efficiency, if the line
resistance and line increases are doubled Figure Q4(b).
R
XL
Vs
Vn
Figure Q4(b)
Load
Q4(b) The equivalent circuit of a single phase short transmission line is shown
in Figure Q4(b). Here, the total line resistance and inductance are shown
as lumped instead of being distributed.
i) Sketch the phasor diagram and assess with by labeling the details for
the A.C. series circuit shown in Figure Q4(b) for the lagging power factor
at load point (Vn).
ii) Summarize, what if the load change from low value to high value
shown in Figure Q4(b).
R
XL
el
Vs
Vn
Figure Q4(b)
Load
Chapter 4 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 4 - ACSR stands for Aluminum-clad steel conductor...Ch. 4 - Overhead transmission-line conductors are bare...Ch. 4 - Alumoweld is an aluminum-clad steel conductor....Ch. 4 - EHV lines often have more than one conductor per...Ch. 4 - Shield wires located above the phase conductors...Ch. 4 - Conductor spacings, types, and sizes do have an...Ch. 4 - A circle with diameter Din.=1000Dmil=dmil has an...Ch. 4 - An ac resistance is higher than a dc resistance....Ch. 4 - Prob. 4.9MCQCh. 4 - Transmission line conductance is usually neglected...
Ch. 4 - Prob. 4.11MCQCh. 4 - Prob. 4.12MCQCh. 4 - For a single-phase, two-wire line consisting of...Ch. 4 - For a three-phase three-wire line consisting of...Ch. 4 - For a balanced three-phase positive-sequence...Ch. 4 - A stranded conductor is an example of a composite...Ch. 4 - lnAk=lnAk True FalseCh. 4 - Prob. 4.18MCQCh. 4 - Expand 6k=13m=12Dkm.Ch. 4 - Prob. 4.20MCQCh. 4 - For a single-phase two-conductor line with...Ch. 4 - In a three-phase line, in order to avoid unequal...Ch. 4 - For a completely transposed three-phase line...Ch. 4 - Prob. 4.24MCQCh. 4 - Does bundling reduce the series reactance of the...Ch. 4 - Does r=e14r=0.788r, which comes in calculation of...Ch. 4 - In terms of line-to-line capacitance, the...Ch. 4 - For either single-phase two-wire line or balanced...Ch. 4 - Prob. 4.29MCQCh. 4 - Prob. 4.30MCQCh. 4 - Prob. 4.31MCQCh. 4 - Prob. 4.32MCQCh. 4 - Prob. 4.33MCQCh. 4 - Prob. 4.34MCQCh. 4 - The affect of the earth plane is to slightly...Ch. 4 - When the electric field strength at a conductor...Ch. 4 - Prob. 4.37MCQCh. 4 - Prob. 4.38MCQCh. 4 - Considering two parallel three-phase circuits that...Ch. 4 - The Aluminum Electrical Conductor Handbook lists a...Ch. 4 - The temperature dependence of resistance is also...Ch. 4 - A transmission-line cable with a length of 2 km...Ch. 4 - One thousand circular mils or 1 kcmil is sometimes...Ch. 4 - A 60-Hz, 765-kV, three-phase overhead transmission...Ch. 4 - A three-phase overhead transmission line is...Ch. 4 - If the per-phase line loss in a 70-km-long...Ch. 4 - A 60-Hz, single-phase two-wire overhead line has...Ch. 4 - Prob. 4.9PCh. 4 - A 60-Hz, three-phase three-wire overhead line has...Ch. 4 - Prob. 4.11PCh. 4 - Find the inductive reactance per mile of a...Ch. 4 - A single-phase overhead transmission line consists...Ch. 4 - Prob. 4.14PCh. 4 - Find the GMR of a stranded conductor consisting of...Ch. 4 - Prob. 4.16PCh. 4 - Determine the GMR of each of the unconventional...Ch. 4 - A 230-kV, 60-Hz, three-phase completely transposed...Ch. 4 - Prob. 4.19PCh. 4 - Calculate the inductive reactance in /km of a...Ch. 4 - Rework Problem 4.20 if the bundled line has (a)...Ch. 4 - Prob. 4.22PCh. 4 - Prob. 4.23PCh. 4 - Prob. 4.24PCh. 4 - For the overhead line of configuration shown in...Ch. 4 - Prob. 4.26PCh. 4 - Figure 4.34 shows double-circuit conductors'...Ch. 4 - For the case of double-circuit, bundle-conductor...Ch. 4 - Prob. 4.29PCh. 4 - Figure 4.37 shows the conductor configuration of a...Ch. 4 - Prob. 4.32PCh. 4 - Prob. 4.33PCh. 4 - Prob. 4.34PCh. 4 - Prob. 4.35PCh. 4 - Prob. 4.36PCh. 4 - Prob. 4.38PCh. 4 - Calculate the capacitance-to-neutral in F/m and...Ch. 4 - Prob. 4.40PCh. 4 - Prob. 4.41PCh. 4 - Prob. 4.42PCh. 4 - Three ACSR Drake conductors are used for a...Ch. 4 - Consider the line of Problem 4.25. Calculate the...Ch. 4 - Prob. 4.45PCh. 4 - Prob. 4.46PCh. 4 - Prob. 4.47PCh. 4 - The capacitance of a single-circuit, three-phase...Ch. 4 - Prob. 4.49PCh. 4 - Prob. 4.50PCh. 4 - Prob. 4.51PCh. 4 - Approximately how many physical transmission...Ch. 4 - Prob. BCSQCh. 4 - Prob. CCSQCh. 4 - Prob. DCSQ
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- For the case of double-circuit, bundle-conductor lines, the same method indicated in Problem 4.27 applies with r' replaced by the bundles GMR in the calculation of the overall GMR. Now consider a double-circuit configuration shown in Figure 4.36 that belongs to a 500-kV, three-phase line with bundle conductors of three subconductors at 21 in. spacing. The GMR of each subconductor is given to be 0.0485 ft. Determine the inductive reactance of the line in ohms per mile per phase. You may use XL=0.2794logGMDGMR/mi/phasearrow_forwardTransmission line conductance is usually neglected in power system studies. True Falsearrow_forwardThe capacitance of a single-circuit, three-phase transposed line with the configuration shown in Figure 4.38, including ground effect, and with conductors not equilaterally spaced is given by C20lnDeqrlnHmH8 F/m line-to-neutral where Deq=D12D23D133=GMD r= conductors outside radiusHm=(H12H23H13)1/3HS=(H1H2H3)1/3 Now consider Figure 4.39 in which the configuration of a three-phase, single circuit, 345-kV line with conductors having an outside diameter of 1.065 in. is shown. Determine the capacitance to neutral in F/m, including the ground effect. Next, neglecting the effect of ground, see how the value changes.arrow_forward
- Conductor spacings, types, and sizes do have an impact on the series impedance and shunt admittance. True Falsearrow_forward(a) A three phase transposed transmission tower comprises of three-bundled conductor and double-circuit configured in vertical position as shown in Figure 2. Each sub-conductor in each circuit and each phase is an ACSR type, size 477,000 cmil and stranding 26/7. Given the GMR of each sub-conductor is 0.8809 cm and diameter is 2.1793 cm, analyze: i. Inductance in mH/km ii. Capacitance in µF/km 0.75m 7.5m b' 4m 4m 45cm Figure 2arrow_forwardDo hand written if possible..plzarrow_forward
- 4.8. A three-phase transposed line is composed of one ACSR 159,000 cmil, 54/19 Lapwing conductor per phase with flat horizontal spacing of 8 meters as shown in Figure 37. The GMR of each conductor is 1.515 cm. (a) Determine the inductance per phase per kilometer of the line. (b) This line is to be replaced by a two-conductor bundle with 8-m spacing mea- sured from the center of the bundles as shown in Figure 38. The spacing between the conductors in the bundle is 40 cm. If the line inductance per phase is to be 77 percent of the inductance in part (a), what would be the GM R of each new conductor in the bundle? a D12 = 8 m D23 = 8 m %3D %3D -D13 = 16 m- FIGURE 37 Conductor layout for Problem 4.8 (a).arrow_forwardPlease answer both.. I will ratearrow_forwardQuestion number 6 decent handwriting pls both the parts!arrow_forward
- A 60 Hz, three-phase, transposed transmission line, is designed with three bobolink conductors per phase, in horizontal arrangement as shown in the figure below. Distance between consecutive phases is D = 6.2 m and distance among bundle conductors is h =0.5m. Each conductor has a radius of 18 mm and a GMR of 14.39mm. The per phase resistance is 1.677x10-5 2/m. r= 18 mm GMR= 14.39 mm a b h D D The per phase shunt admittance assuming zero conductance in µO/km is: О a., 5.4347 O b. j5.3316 О с /4.2266 O d. j4.0973 O e. 59630.2922 + j10.9770arrow_forwardProblem: A three phase transmission line is being supported by 3 disc insulators. The potential across top unit (near the tower) and middle unit are 8 kV and 11 kV respectively. Determine; i) ratio of capacitance between pin and earth to self capacitance of each unit, ii) the line valtage and iii) string efficiency.arrow_forwardThese 2 parts.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License