The surface of a horizontal. 7-mm-diameter cylinder is maintained at an excess temperature of 5°C in saturated water at 1 atm. Estimate the heat flux using an appropriate free convection correlation and compare your result to the boiling curve of Figure 10.4. Repeat the calculation for a horizontal. 7-
Want to see the full answer?
Check out a sample textbook solutionChapter 10 Solutions
Fundamentals of Heat and Mass Transfer
Additional Engineering Textbook Solutions
Applied Fluid Mechanics (7th Edition)
Mechanics of Materials (10th Edition)
Vector Mechanics for Engineers: Statics and Dynamics
Thinking Like an Engineer: An Active Learning Approach (3rd Edition)
Fox and McDonald's Introduction to Fluid Mechanics
Automotive Technology: Principles, Diagnosis, and Service (5th Edition)
- Please help me with the problem shown in the figure thanksarrow_forwardWater at atmospheric pressure is boiled in a container using a horizontal 8 mm electric wire (ε=0.9) whose temperature is maintained by an electric current at 250oC. Estimate the boiling heat transfer coefficient between the water and the wire surface. Properties of Water, liquid: ρl = 957.9 kg/m3, hfg = 2257 kJ/kg, vapor: ρv = 4.8 kg/m3, Cp,v = 2560 J/kg.K, μv = 14.85*10-6 N.s/m2, kv=0.0331 W/mK. Select one: a. 247 W/m2K b. 440 W/m2K c. 90.7 W/m2K d. 710 W/m2Karrow_forwardcan you answer the questionarrow_forward
- .All properties should be evaluated at the temperature of the steam.Saturated, pure steam at 65 ºC condenses on the surface of a vertical tube with outersurface diameter 2 cm which is maintained at a uniform temperature of 35 ºC. Determinethe tube length for a condensate flow rate of 5 x 10-3 kg/s.arrow_forwardneed soon all parts don't copy I will downvotearrow_forwardThere is a long rod, insulated to avoid any heat loss on its sides, is in perfect thermal contact with the boiling water (at atm pressure) at of the one end and with the ice-water mixture. The rod has a 1.00 m section of copper (with one end in boiling water) connected and joined together end-to-end to a length, L2, of steel (with one end in the ice water). Both sections of the rod have cross-sectional areas = 4.00 cm2. The temperature of the copper-steel junction is 65.0 °C after a steady state has been met. How much heat per second flows from the boiling water to the ice-water mixture? kCopper = 380 W/m*K kStainless Steel = 50 W/m*K A. How much heat per sec (watts) flows from boiling water to ice water mixture? B. Find the length L2 of steel section in metersarrow_forward
- Explain the cooling effect of evaporation in terms of latent heat of vaporization.arrow_forward8.2 From its definition and from the property values in Appendix 2, Table 13, calculate the coefficient of thermal expansion, , for saturated water at 403 K. Then compare your results with the value in the table.arrow_forwarda film-type condenser consists of a packed bed of 3-cm diameter spheres with a voidage of 35%. water sprayed onto the bed at 60oC is used to condense steam entering at the base at a saturation temperature of 100oC. How deep must the bed be to ensure complete condensation of the steam, and what is the outlet temperature of the water? (Use water properties based on the mean of the inlet and outlet water temperatures, and iterate if necessary)arrow_forward
- Analyze the condensation process using both chillers. Provide operating temperatures and pressures entering each component shown in the diagram (at points 1, 2, 3, 4). Indicate which chiller should be chosen based on the economics. See below for details: -Your work is replacing a chiller that is used as part of a distillation process that condenses methanol (boiling point = 65 °C). Your task is to select the most economical type of system. A conventional chiller will have a lower first cost and will have lower maintenance costs than one that involves enhanced heat transfer surfaces, but the chiller with enhanced surfaces will condense the same amount of alcohol with a lower energy consumption. Select the appropriate chiller by considering the net present value of both systems. That value will involve the first cost of the chiller, and the present value of the maintenance and energy costs. The chiller uses a standard vapor-compression refrigeration cycle with R-22 (see Figure 1). For…arrow_forwardEstimate the interfacial heat transfer coefficient for evaporation of a thin film of saturated liquid water at atmospheric pressure. The liquid film rests on a flat, solid surface to which a constant and uniform heat flux of 150 kW/m? is applied. The accommodation coefficient may be taken to be 0.05. If the liquid film thickness is 0.2 mm, compare the interfacial vaporization resistance with the conduction resistance through the liquid film.arrow_forward*** 32. A double-chambered container contains one mole of helium in one of its 1000 cm³ Pull to volume chambers. The container is well-insulated, and of low specific heat, so that no appre- remove ciable heat is added to the gas during the process we describe. The gas is initially at a tempera- ture of 300 K and a pressure of 1 atmosphere. The partition between the two chambers is then quickly raised, and the gas expands freely to fill the entire container. Whenever a monatomic gas like helium doubles its volume adiabatically like this, the pressure in the gas will drop to 0.315 of what it was before (for reasons that we did not explain in this chapter), so the final 1000 cm3 1000 cm³ pressure of the expanded gas will be 0.315 atmospheres. a) What is the temperature of the gas after the expansion? b) What is the change in the internal energy of the gas? c) How much heat is added to the gas? [Hint: Maybe read the problem again.] d) How much work is done by the gas as it expands? [Hint:…arrow_forward
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning