Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 3, Problem 3.59P
To determine
(a)
The real and reactive power to the load bus from parallel lines with no regulating transformer.
To determine
(b)
The real and reactive power due to increase in voltage magnitude by 0.05 per unit.
To determine
(c)
The real and reactive power due to advance in the phase by
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Design 5th order LPF with gain = Yo
cut of freq=10KHZ
The current coil of a wattmeter is connected in the red
line of a three-phase system. The voltage circuit can be
connected between the red line and either the yellow
line or the blue line by means of a two-way switch.
Assuming the load to be balanced, show with the aid
of a phasor diagram that the sum of the wattmeter
indications obtained with the voltage circuit connected
to the yellow and the blue lines respectively gives the
total active power.
A wattmeter has its current coil connected in the yellow
line, and its voltage circuit is connected between the
red and blue lines. The line voltage is 400 V and the
balanced load takes a line current of 30 A at a power
factor of 0.7 lagging. Draw circuit and phasor diagrams
and derive an expression for the reading on the wattmeter
in terms of the line voltage and current and of the phase
difference between the phase voltage and current.
Calculate the value of the wattmeter indication.
ANS:
. Line amperes × line volts × sin φ = 8750 var
Chapter 3 Solutions
Power System Analysis and Design (MindTap Course List)
Ch. 3 - The Ohms law for the magnetic circuit states that...Ch. 3 - For an ideal transformer, the efficiency is (a) 0...Ch. 3 - For an ideal 2-winding transformer, the...Ch. 3 - An ideal transformer has no real or reactive power...Ch. 3 - For an ideal 2-winding transformer, an impedance...Ch. 3 - Consider Figure 3.4. For an ideal phase-shifting...Ch. 3 - Consider Figure 3.5. Match the following, those on...Ch. 3 - The units of admittance, conductance, and...Ch. 3 - Match the following: (i) Hysteresis loss (a) Can...Ch. 3 - For large power transformers rated more than 500...
Ch. 3 - For a short-circuit test on a 2-winding...Ch. 3 - The per-unit quantity is always dimensionless. (a)...Ch. 3 - Consider the adopted per-unit system for the...Ch. 3 - The ideal transformer windings are eliminated from...Ch. 3 - To convert a per-unit impedance from old to new...Ch. 3 - In developing per-unit circuits of systems such as...Ch. 3 - Prob. 3.17MCQCh. 3 - Prob. 3.18MCQCh. 3 - With the American Standard notation, in either a...Ch. 3 - Prob. 3.20MCQCh. 3 - In order to avoid difficulties with third-harmonic...Ch. 3 - Does an open connection permit balanced...Ch. 3 - Does an open- operation, the kVA rating compared...Ch. 3 - It is stated that (i) balanced three-phase...Ch. 3 - In developing per-unit equivalent circuits for...Ch. 3 - In per-unit equivalent circuits of practical...Ch. 3 - Prob. 3.27MCQCh. 3 - Prob. 3.28MCQCh. 3 - For developing per-unit equivalent circuits of...Ch. 3 - Prob. 3.30MCQCh. 3 - Prob. 3.31MCQCh. 3 - Prob. 3.32MCQCh. 3 - The direct electrical connection of the windings...Ch. 3 - Consider Figure 3.25 of the text for a transformer...Ch. 3 - (a) An ideal single-phase two-winding transformer...Ch. 3 - An ideal transformer with N1=1000andN2=250 is...Ch. 3 - Consider an ideal transformer with...Ch. 3 - A single-phase 100-kVA,2400/240-volt,60-Hz...Ch. 3 - Prob. 3.5PCh. 3 - Prob. 3.6PCh. 3 - Consider a source of voltage v(t)=102sin(2t)V,...Ch. 3 - Prob. 3.8PCh. 3 - Prob. 3.9PCh. 3 - A single-phase step-down transformer is rated...Ch. 3 - For the transformer in Problem 3.10. The...Ch. 3 - Prob. 3.12PCh. 3 - A single-phase 50-kVA,2400/240-volt,60-Hz...Ch. 3 - A single-phase 50-kVA,2400/240-volt,60-Hz...Ch. 3 - Rework Problem 3.14 if the transformer is...Ch. 3 - A single-phase, 50-kVA,2400/240-V,60-Hz...Ch. 3 - The transformer of Problem 3.16 is supplying a...Ch. 3 - Using the transformer ratings as base quantities,...Ch. 3 - Using the transformer ratings as base quantities....Ch. 3 - Using base values of 20 kVA and 115 volts in zone...Ch. 3 - Prob. 3.21PCh. 3 - A balanced Y-connected voltage source with...Ch. 3 - Figure 3.32 shows the oneline diagram of a...Ch. 3 - For Problem 3.18, the motor operates at full load,...Ch. 3 - Consider a single-phase electric system shown in...Ch. 3 - A bank of three single-phase transformers, each...Ch. 3 - A three-phase transformer is rated...Ch. 3 - For the system shown in Figure 3.34. draw an...Ch. 3 - Consider three ideal single-phase transformers...Ch. 3 - Reconsider Problem 3.29. If Va,VbandVc are a...Ch. 3 - Prob. 3.31PCh. 3 - Determine the positive- and negative-sequence...Ch. 3 - Consider the three single-phase two-winding...Ch. 3 - Three single-phase, two-winding transformers, each...Ch. 3 - Consider a bank of this single-phase two-winding...Ch. 3 - Three single-phase two-winding transformers, each...Ch. 3 - Three single-phase two-winding transformers, each...Ch. 3 - Consider a three-phase generator rated...Ch. 3 - The leakage reactance of a three-phase,...Ch. 3 - Prob. 3.40PCh. 3 - Consider the single-line diagram of the power...Ch. 3 - For the power system in Problem 3.41, the...Ch. 3 - Three single-phase transformers, each rated...Ch. 3 - A 130-MVA,13.2-kV three-phase generator, which has...Ch. 3 - Figure 3.39 shows a oneline diagram of a system in...Ch. 3 - The motors M1andM2 of Problem 3.45 have inputs of...Ch. 3 - Consider the oneline diagram shown in Figure 3.40....Ch. 3 - With the same transformer banks as in Problem...Ch. 3 - Consider the single-Line diagram of a power system...Ch. 3 - A single-phase three-winding transformer has the...Ch. 3 - The ratings of a three-phase three-winding...Ch. 3 - Prob. 3.52PCh. 3 - The ratings of a three-phase, three-winding...Ch. 3 - An infinite bus, which is a constant voltage...Ch. 3 - A single-phase l0-kVA,2300/230-volt,60-Hz...Ch. 3 - Three single-phase two-winding transformers, each...Ch. 3 - A two-winding single-phase transformer rated...Ch. 3 - A single-phase two-winding transformer rated...Ch. 3 - Prob. 3.59PCh. 3 - PowerWorid Simulator case Problem 3_60 duplicates...Ch. 3 - Rework Example 3.12 for a+10 tap, providing a 10...Ch. 3 - A 23/230-kV step-up transformer feeds a...Ch. 3 - The per-unit equivalent circuit of two...Ch. 3 - Reconsider Problem 3.64 with the change that now...Ch. 3 - What are the advantages of correctly specifying a...Ch. 3 - Why is it important to reduce the moisture within...Ch. 3 - What should be the focus of transformer preventive...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 4. The circuit shown below shows an infinite impedance (open circuit) in phase B of the Y-connected load. Find the phasor voltage VOB if the system is 208 V, sequence ABC. -j100 Q 100 Ω B 5. Three identical impedances of Z = 15260°2 are connected in Y to a three-phase, three-wire, 240 V, ABC system. The lines between the supply and the load have impedances of 2 +j 1 Q2. Find the line voltage magnitudes at the load. Find the new values when a set of capacitors with reactance of -j10 Q (Y-connection) is connected in parallel with the load. Draw the vector diagram for the load current, the capacitor current and the system line current.arrow_forward1. A three-phase, three-wire, 240 V, ABC system supplies a delta-connected load in which ZAB = 25/90°, ZBC = 15230° and ZCA = 200°. a) Find the line currents and the total real and reactive powers supplied by the source. Draw the phasor diagram for the line voltages and phase and line currents. Vc VA AT VB ICT 1 CA ZAB | BT ZBC b) A 240 V, 2 HP, 0.95 efficiency, single-phase motor is connected as shown below. The motor is operating at 0.85 p.f. lagging. Repeat (a). Include the motor current in the phasor diagram VA AT ZAB Ꮓ ΑΒ V B CT 1BT M ZBC ZCAarrow_forward2. A three-phase, four-wire, 208 V, ABC system supplies a Y-connected load in which Zд = 100°N, Z = 15/30° and Zc = 104-30°. Find the line currents, the neutral current and total real and reactive powers. Draw the phasor diagram of the phase voltages and currents. ZA = 3. A three-phase, three-wire, 208 V, ABC system supplies a Y-connected load in which ZA 100°, ZB = 15230° and Zc = 10-30°. Find the line currents, the phase voltages across the load impedances, the total real and reactive powers and the voltage Von VA ZAarrow_forward
- Don't use ai to answer I will report you answerarrow_forwardDiscuss the importance of power-factor correction in a.c. systems. A 400 V, 50 Hz, three-phase distribution system supplies a 20 kVA, three-phase induction motor load at a power factor of 0.8 lagging, and a star-connected set of impedances, each having a resistance of 10 Ω and an inductive reactance of 8 Ω. Calculate the capacitance of delta-connected capacitors required to improve the overall power factor to 0.95 lagging. ANS: 75 µF/pharrow_forwardA 3-phase, wye-connected generator induces 2400 V in each of its windings. Calculate the line voltage.arrow_forward
- why Low Pass filter (LPF) R₁C=S V₁ R т Tc Voarrow_forwardDon't use ai to answer I will report you answerarrow_forwardA 60hp,3-phase motor absorbs 50 kW from a 600 V,3-phase line. If the line current is 60 A, calculate the following: a. The efficiency of the motor b. The apparent power absorbed by the motor c. The reactive power absorbed by the motor and the power factor of the motorarrow_forward
- Three 15Ω resistors and three 8Ω reactors are connected as shown in Fig. 18. If the line voltage is 530 V, calculate the following: a. The active, reactive, and apparent power supplied to the 3 -phase load b. The voltage across each resistorarrow_forwardThree resistors are connected in delta. If the line voltage is 13.2kV and the line current is 1202 A, calculate the following: A) the current in and the voltage acroos each resistor B) The power supplied to each resistor and the 3 phase load C) The ohmic value of each resistorarrow_forwardWith the aid of a phasor diagram show that the active power and power factor of a balanced three-phase load can be measured by two wattmeters. For a certain load, one wattmeter indicated 20 kW and the other 5 kW after the voltage circuit of this wattmeter had been reversed. Calculate the active power and the power factor of the load. ANS: 15 kW, 0.327arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
TRANSFORMERS - What They Are, How They Work, How Electricians Size Them; Author: Electrician U;https://www.youtube.com/watch?v=tXPy4OE7ApE;License: Standard Youtube License