Textbook Question
Chapter 3, Problem 3.31P
The sensible heat loss from a space is 500,000 Btu/hr (146 kW) and the latent heat loss due to infiltration is 50,000 Btu/hr (14.6 kW). The space is to be maintained at 72 F (22 C) and 30 percent relative humidity. Construct the condition line on (a) Charts 1a and 1b. (b) If air is supplied at 115 F (46 C), what is the volume flow rate?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Moist air enters a duct at 10oC, 80% relative humidity, and a volumetric flow rate of 81m3/min. The air is heated as it flows through the duct and exists at 34oC. No moisture is added or removed.
Draw the cycle on the attached chart and determine:
a) The rate of heat transfer in KJ/s;
b) The relative humidity at the exit.
Using a psychometric diagram, describe the heating and humidification process from the following data. Initially the air was at dry bulb temperature (DBT) 35 ° C and RH 35%. air preheated to DBT 85 ° C. The heated air is then flowed through a humidifier to increase the RH to 25%. for this process, count,
a. change in absolute humidity of air from initial to final conditions = ..... (kg water / kg air)
b. change in air enthalpy from initial to final conditions = ..... (kj / kg air)
On a hot summer day, the temperature is 35 ° C, barometric pressure 103 kPa and relative humidity 90%. One The air conditioner draws the outside air and cools it to 20 ° C and raises the air to 12500 L / h. Calculate the condensation rate of the moisture (kg / h) and the flow rate of the air drawn from the outside.
Chapter 3 Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Ch. 3 - A space is at a temperature of 75 F (24 C), and...Ch. 3 - Determine the humidity ratio, enthalpy, and...Ch. 3 - Suppose the air of Problem 3-2 is at a pressure...Ch. 3 - What is the enthalpy of moist air at 70 F (20 C)...Ch. 3 - The inside surface temperature of a window in a...Ch. 3 - What is the mass flow rate of dry air flowing at a...Ch. 3 - Determine the dew point of moist air at 80 F (27...Ch. 3 - A room is to be maintained at 72 F (22 C) db. It...Ch. 3 - Air is cooled from 80 F db and 67 F wb until it is...Ch. 3 - Conditions in a room are measured to be 80 F db...
Ch. 3 - The environmental conditions in a room are to be...Ch. 3 - Air enters a cooling coil at the rate of 5000 cfm...Ch. 3 - Air flowing in a duct has dry and wet bulb...Ch. 3 - Air is humidified with the dry bulb temperature...Ch. 3 - Air at 38 C db and 20 C wb is humidified...Ch. 3 - Two thousand cfm (1.0 m3/s) of air at an initial...Ch. 3 - Air at 40 F (5 C) db and 35 F (2 C) wb is mixed...Ch. 3 - Rework Problem 3-25, using Chart 1a, with the...Ch. 3 - The design cooling load for a zone in a building...Ch. 3 - Assume that the air in Problem 3-22 is supplied to...Ch. 3 - The sensible heat loss from a space is 500,000...Ch. 3 - Air enters a refrigeration coil at 90 Fdb and 75...Ch. 3 - A building has a total heating load of 200,000...Ch. 3 - Reconsider Problem 3-36 for an elevation of 5000...Ch. 3 - The system of Problem 3-34 has a supply air fan...Ch. 3 - An evaporative cooling system is to be used to...Ch. 3 - A cooling system is being designed for use at high...Ch. 3 - Consider a space heating system designed as shown...Ch. 3 - A variable-air-volume VAV cooling system is a type...Ch. 3 - Rework Problem 3-43 for an elevation of 5000 feet...Ch. 3 - The design condition for a space is 77 F (25 C) db...Ch. 3 - Rework Problem 3-45 for an elevation of 5000 feet...Ch. 3 - It is necessary to cool and dehumidify air from 80...Ch. 3 - Conditions in one zone of a dual-duct conditioning...Ch. 3 - Rework Problem 3-48 for an elevation of 5000 ft...Ch. 3 - A water coil in Problem 3-48 cools return air to...Ch. 3 - A multizone air handler provides air to several...Ch. 3 - Under normal operating conditions a zone has a...Ch. 3 - An interior zone of a large building is designed...Ch. 3 - Outdoor air is mixed with room return air to...Ch. 3 - Consider an enclosed swimming pool. The pool area...Ch. 3 - One particular zone served by a multizone air...Ch. 3 - A research building requires 100 percent outdoor...Ch. 3 - A space requires cooling in the amount of 120,000...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
Determine the force in members CD, CF, and CG and state if these members are in tension or compression. Probs. ...
INTERNATIONAL EDITION---Engineering Mechanics: Statics, 14th edition (SI unit)
Suppose you had a machining operation (boring) running perfectly and you changed work materials. All of a sudde...
DeGarmo's Materials and Processes in Manufacturing
A rectangular gate is installed in a vertical wall of a reservoir, as shown in Fig. 4.26 Compute the magnitude ...
Applied Fluid Mechanics (7th Edition)
In an isothermal process, 0.1 cubic feet of standard air per minute (SCFM) is pumped into a balloon. Tension in...
Fox and McDonald's Introduction to Fluid Mechanics
The sign has a mass of 100 kg with center of mass at G. Determine the x, y, z components of reaction at the bal...
Statics and Mechanics of Materials (5th Edition)
Construct the v t graph for the time interval 0 t t, where t is the time for the car to come to rest.
Engineering Mechanics: Dynamics (14th Edition)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- ASHRAE standard 62.2 states that the minimum acceptable rate of airflow into and out of a room is 15cfm (cubic feet per minute). If air is supplied at 68°F with a relative humidity of 45%, how many gallons of water (minimum) must be added to a portable room humidifier before you go to sleep if you would like to maintain the room at 65% humidity for 7 hours?arrow_forwardPls. Answer..thank you! An air-conditioning system operates at a total pressure of 1 atm and consists of a heating section and an evaporative cooler. Air enters the heating section at 15OC and 55 percent relative humidity at a rate of 30 m3 /min, and it leaves the evaporative cooler at 25OC and 45 percent relatively humidity. Determine the TOR.arrow_forwardPls. Answer thank you!Atmospheric air from the inside of an automobile enters the evaporator section of the air conditioner at 1 atm, 27 C and 50 percent relative humidity. The air returns to the automobile at 10 C and 90 percent relative humidity. The passenger compartment has a volume of 2 m3 and 5 air changes per minute are required to maintain the inside of the automobile at the desired comfort level. Sketch the psychrometric diagram for the atmospheric air flowing through the air conditioning process. Determine the dew point and wet bulb temperatures at the inlet to the evaporator section, in 8 C. the required heat transfer rate from the atmospheric air to the evaporator fluid, in kW. the rate of condensation of water vapor in the evaporator section, in kg/min.arrow_forward
- Q2) Air is supplied to an automobile cabin from the outside, where the temperature is 20F and the relative humidity is 70%. It is desired to keep the cabin at 70F and Ø = 60%. Hoe many pounds of water must be supplied to each pound of air entering the car cabin if these conditions are to be met? The barometric pressure is 29.5 in.Hg. %3D Ans. (0.00797 lbs/Ibdry air)arrow_forwardA water pipe at 5°C runs above ground between two buildings. The surrounding air is at 35°C. What is the maximum relative humidity the air can have before condensation occurs on the pipe?arrow_forwardplease solve in 5o mins i will give you positive feedback. i need handwritten solution on pagesarrow_forward
- i was trying to understand and studying thermodynamics course but this example had seen pretty hard to me. thanks to the person who can explain the solution of that example to me.arrow_forwardThe design condition for a space is 77oF db and 50% relative humidity with 55oF db supply air at 90% relative humidity. A 50-ton, constant-volume space air- conditioning system uses face and bypass and water temperature control. Outdoor air is supplied at 95oF db, 60% relative humidity with a ratio of 1 lbm to 5 lbm re-circulated air. A part-load condition exists where the total space load is decreased by 50% and the SHF is increased to 90%. The outdoor air condition changes to 85oF db and 70% relative humidity. Assume sea-level conditions. a) At full – load conditions:a. Show all the processes on a psychrometric chart.b. Determine the temperature must the air be supplied to the space at fullload conditions.c. Determine the apparatus dew point temperature at full load conditions. b)At part – load conditions:a. Show all the processes on a psychrometric chart.b. Determine the temperature must the air be supplied to the space at partload conditions.c. Determine the apparatus dew point…arrow_forwardPlease answer step by steparrow_forward
- 3. Air enters a window air conditioner at 1 atm, 30 C, and 80 percent relative humidity at a rate of 10 m/min, and it leaves as saturated air at 14 C. Part of the moisture in the air that condenses during the process is also removed at 14 C. Determine the rates of heat and moisture removal from the air. ,= 80% - 100% 14°C Cooling coils tooo0000 Air Cowdensate, Codensatearrow_forwardA space is to be maintained at 75 F db and 40% relative humidity. The total heat gain to the space is 62,000 Btu/hr with a SHF of 0.8. The outdoor air requirement is 500 cfm. The outdoor air has a temperature of 90 F and 50% relative humidity. Assume that the supply air has a temperature of 50 F db. Determine the following: a. Quantity of supplied air b. Capacity of the cooling coil c. Rate of moisture removal from the dehumidification elementarrow_forwardNote: The answer should be typed.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY