A space requires cooling in the amount of 120,000 Btufhr (35.2 kW) with a SHF of 0.5. Room conditions are 75 F (24 C); 50 percent relative humidity (RH). Outdoor air conditions are 90 F db and 75 F wb (32 C db and 24 C wb, respectively). One-third of the supply air is outdoor air. The coil SHF is 0.6 and can cool the air to 90 percent relative humidity (RH). Devise a system of processes to condition the room using Chart 1a, and compute heat transfer and flow rates for all the processes. Assume local elevation of 5000 ft (1500 m).
Want to see the full answer?
Check out a sample textbook solutionChapter 3 Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Additional Engineering Textbook Solutions
Automotive Technology: Principles, Diagnosis, And Service (6th Edition) (halderman Automotive Series)
DeGarmo's Materials and Processes in Manufacturing
Fundamentals of Heat and Mass Transfer
Mechanics of Materials
Degarmo's Materials And Processes In Manufacturing
Introduction to Heat Transfer
- HVAC UPVOTE WILL BE GIVEN. ANSWERS ARE GIVEN ALREADY. PLEASE WRITE THE COMPLETE SOLUTIONS. A tank contains 7 kg of dry air and 0.1 kg of H₂o vapor at 30°C (Psat = 4.286 kPa) and 100kPa total pressure. Determine the following: a) Specific Humidity (Ans. 0.0143) b.) Relative Humidity (Ans. 0.529) c.) Volume of the tank (Ans. 6.23)arrow_forwardDuring a gas process, the pressure on 3.63 kg of air drops from 80 psia to 5 psig, while temperature remained constant at 31.11 deg C. What is the change in internal energy? 445 KJ O BTU None of the above 421 BTUarrow_forward1. In the process of air conditioning in a humidifier, the air at a dry bulb temperature of 20 °C and 25% RH increases its RH to 40%. Determine the amount of moisture added in the humidifier per kg of dry air. = (kg water/kg air). 2. The air has a dry bulb temperature of 34 °C and a wet bulb temperature of 22°C. The liquid is heated in a heater so that the dry bulb temperature increases to 80 °C. Then the air is passed through the corn kernels to dry. The air coming out of the corn kernels is at bulb temperature. dry 55 °C Then this air is passed to the dehumidifier to reduce its RH to 10%. Draw the course of the air change process on a psychrometric diagram. The rate of air flow through the corn kernels and dehumidifier is 4.0 m/s and the cross-sectional diameter of the pile is 0.7 m. a) Determine the amount of water content lost from the pile of corn kernels (in grams of water/second) b) Determine the amount of water content lost from the air when passing through the…arrow_forward
- Calculate the amount of sensible heat that must be added to 50 kg of air at 30 deg C Tdb and 23 deg C Twb to raise the temperature of air to 50 deg C dry bulb.arrow_forwardIn a place where a summer air-conditioning plant will be installed, 40% of the air entering the air-conditioning plant is the fresh air, and 60% is the return (bypass) air. The sensible heat gain of the place is 10 kW. and the latent heat gain is 2.5 kW.> Outdoor conditions: 32 °C DB, %50 RH.> Indoor conditions: 20 °C DB. %50 RH.> Take the relative humidity of the air passing through the cooling coil 90% at the coil outlet. > The total air flow rate in the mixing chamber is 3000 m3/h> Take the density of the air as 1.2 kg/m3Based on the above. Calculate the amount of fresh air. What is the value of enthalpy of blowing air. Calculate the ratio of by-pass air at cooling coil. Calculate the flow rate of by-passed air.arrow_forwardIn a place where a summer air-conditioning plant will be installed, 40% of the air entering the air-conditioning plant is the fresh air, and 60% is the return (bypass) air. The sensible heat gain of the place is 10 kW. and the latent heat gain is 2.5 kW.> Outdoor conditions: 32 °C DB, %50 RH.> Indoor conditions: 20 °C DB. %50 RH.> Take the relative humidity of the air passing through the cooling coil 90% at the coil outlet. > The total air flow rate in the mixing chamber is 3000 m3/h> Take the density of the air as 1.2 kg/m3Based on the above.a) Show the process on a psychrometric diagram. b) Calculate the amount of fresh air. c) What is the value of enthalpy of blowing air. d) Calculate the ratio of by-pass air at cooling coil. e) Calculate the flow rate of by-passed air.arrow_forward
- Thermodynamics: An air conditioning system operates at a pressure of 1 atm. The system has a heating section and an air-conditioning section that provides saturated water vapor at 105 °C.The air enters the heating section at 15 oC and 60 percent relative humidity with a volume flow of 30 m3 / minute and leaves the humidification section at 25 oC and 50 percent relative humidity. a) Find the temperature and relative humidity of the air when leaving the heater section b)Calculate the heat transfer in the heating section [kJ/min] c)Calculate the water flow rate added in the humidification section [ kg/min] NOTE:Please send the solution manually on paper.arrow_forwardThe total volume of a new house is 685 m3. Before the heat is turned on, the air temperature inside is 10°C, and the relative humidity is 46 percent. After the air is warmed to 15°C how much water vapor must be added to the air to make the relative humidity 46 percent?arrow_forwardQ2) Air is supplied to an automobile cabin from the outside, where the temperature is 20F and the relative humidity is 70%. It is desired to keep the cabin at 70F and Ø = 60%. Hoe many pounds of water must be supplied to each pound of air entering the car cabin if these conditions are to be met? The barometric pressure is 29.5 in.Hg. %3D Ans. (0.00797 lbs/Ibdry air)arrow_forward
- A hall is to be air conditioned under the following conditions: Inside and outside design conditions (24 cº DBT, 60 % RH) and(38 cº DBT, 28 cº WBT). Sensible heat load in the room 160000 kJ/hr 40000 kJ/hr BL - Latent heat load in the room Total infiltrated air Apparatus dew point temperature. L1200 m³/hr ! 10 c The quantity of recirculated air from the hall is 60 % of the total. If the quantity of the recirculated air is mixed with the conditioned air after the cooling coil. Find the following: 1-The conditions of air leaving the conditioner coil and before mixing with the recirculated airc MIVE 2-Conditions of air before entering the hall. 3-The mass of air entering the hall. Do 4-The mass of total áir passing through the coil. 5-Bypass factor of the cooling coil. 6-The refrigeration capacity of the cooling coil in the tons of refrigeration. .arrow_forwardA sling psychrometer has a dry bulb reading of 30°C and a wet bulb reading of 17°C. Find the relative humidity and humidity ratio. Show your work on the psychrometric chart given in Figure 1. 0.03 30°C 0.025 Atmospheric pressure 101.330 kPa 0.02 Wet bulb temp. 25°C 60% 40%A 0.015 15°C 0.01 10°C Relative humidity 20% 0.005 10 20 30 40 50 Dry-bulb temperature - °C Humidity ratio (@) - kg moisture/kg dry air %Ó8 %001arrow_forward2. A fuel oil of 20⁰API at a temperature of 15.6⁰C has a heating value of 44, 240 kJ/kg. Determine the following: a. HHV of this fuel oil at 15.6⁰C in kJ/L.b. LHV of this fuel in kJ/kg.c. HHV of this fuel oil at 60⁰C in kJ/Ld. Specific gravity of this fuel oil in degrees Baume at 15.6⁰C.arrow_forward
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning