Heating Ventilating and Air Conditioning: Analysis and Design
6th Edition
ISBN: 9780471470151
Author: Faye C. McQuiston, Jeffrey D. Spitler, Jerald D. Parker
Publisher: Wiley, John & Sons, Incorporated
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 3, Problem 3.11P
Air is cooled from 80 F db and 67 F wb until it is saturated at 55 F. Using Chart 1a, find (a) the moisture removed per pound of dry air, (b) the heat removed to condense the moisture, (c) the sensible heat removed, and (d) the total amount of heat removed.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
16. Determine the average c_ value in kJ/kg-K of a gas if 532kJ/kg of heat is necessary to raise the
p
temperature from 300K to 800K making the pressure constant.
what is true of the heat content for a system at constant pressure
Calculate the enthalpy change of 1 kg of 30 ° C water to 190 ° C saturated vapor, and determine the vapor pressure. a. Change in enthalpy (Singh's Book Tab A 4.2) = Answer kJ. b. Saturated vapor pressure = Answer kPa
Chapter 3 Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Ch. 3 - A space is at a temperature of 75 F (24 C), and...Ch. 3 - Determine the humidity ratio, enthalpy, and...Ch. 3 - Suppose the air of Problem 3-2 is at a pressure...Ch. 3 - What is the enthalpy of moist air at 70 F (20 C)...Ch. 3 - The inside surface temperature of a window in a...Ch. 3 - What is the mass flow rate of dry air flowing at a...Ch. 3 - Determine the dew point of moist air at 80 F (27...Ch. 3 - A room is to be maintained at 72 F (22 C) db. It...Ch. 3 - Air is cooled from 80 F db and 67 F wb until it is...Ch. 3 - Conditions in a room are measured to be 80 F db...
Ch. 3 - The environmental conditions in a room are to be...Ch. 3 - Air enters a cooling coil at the rate of 5000 cfm...Ch. 3 - Air flowing in a duct has dry and wet bulb...Ch. 3 - Air is humidified with the dry bulb temperature...Ch. 3 - Air at 38 C db and 20 C wb is humidified...Ch. 3 - Two thousand cfm (1.0 m3/s) of air at an initial...Ch. 3 - Air at 40 F (5 C) db and 35 F (2 C) wb is mixed...Ch. 3 - Rework Problem 3-25, using Chart 1a, with the...Ch. 3 - The design cooling load for a zone in a building...Ch. 3 - Assume that the air in Problem 3-22 is supplied to...Ch. 3 - The sensible heat loss from a space is 500,000...Ch. 3 - Air enters a refrigeration coil at 90 Fdb and 75...Ch. 3 - A building has a total heating load of 200,000...Ch. 3 - Reconsider Problem 3-36 for an elevation of 5000...Ch. 3 - The system of Problem 3-34 has a supply air fan...Ch. 3 - An evaporative cooling system is to be used to...Ch. 3 - A cooling system is being designed for use at high...Ch. 3 - Consider a space heating system designed as shown...Ch. 3 - A variable-air-volume VAV cooling system is a type...Ch. 3 - Rework Problem 3-43 for an elevation of 5000 feet...Ch. 3 - The design condition for a space is 77 F (25 C) db...Ch. 3 - Rework Problem 3-45 for an elevation of 5000 feet...Ch. 3 - It is necessary to cool and dehumidify air from 80...Ch. 3 - Conditions in one zone of a dual-duct conditioning...Ch. 3 - Rework Problem 3-48 for an elevation of 5000 ft...Ch. 3 - A water coil in Problem 3-48 cools return air to...Ch. 3 - A multizone air handler provides air to several...Ch. 3 - Under normal operating conditions a zone has a...Ch. 3 - An interior zone of a large building is designed...Ch. 3 - Outdoor air is mixed with room return air to...Ch. 3 - Consider an enclosed swimming pool. The pool area...Ch. 3 - One particular zone served by a multizone air...Ch. 3 - A research building requires 100 percent outdoor...Ch. 3 - A space requires cooling in the amount of 120,000...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
3.3 It is known that a vertical force of 200 lb is required to remove the nail at C from the board. As the nail...
Vector Mechanics for Engineers: Statics, 11th Edition
The moment of inertia Iy for the slender rod in terms of the rod’s total mass m .
Engineering Mechanics: Statics & Dynamics (14th Edition)
Comprehension Check 7-14
The power absorbed by a resistor can be given by P = I2R, where P is power in units of...
Thinking Like an Engineer: An Active Learning Approach (3rd Edition)
5.1 through 5.9
Locate the centroid of the plane area shown.
Fig. P5.1
Vector Mechanics for Engineers: Statics and Dynamics
Assume the following vectors are already defined: V1=[302]V2=[214]V3=[5131]V4=[0.50.10.20.2] For each of the fo...
Thinking Like an Engineer: An Active Learning Approach (4th Edition)
Locate the centroid of the area. Prob. 9-17
Engineering Mechanics: Statics
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Relative humidity represents .3 the water vapour in the air under low temperature to the water vapour amount in the air under high temperature. the real water vapour amount in the air per the maximum vapour amount that the air could contain. none of these answers. O the water vapour amount in the air per unit mass of the air.arrow_forward* Your answer is incorrect. Water contained in a piston-cylinder assembly, initially at 300°F, a quality of 80%, and a volume of 6 ft3, is heated at constant temperature to saturated vapor. If the rate of heat transfer is 0.3 Btu/s, determine the time, in min, for this process of the water to occur. Kinetic and potential energy effects are negligible. At = i 5.217 minarrow_forward1. During a polytropic process, 10 lb of an ideal gas, whose R=40 ft.lb/lb.R and c = 0.25 Btu/lb.R, changes state from 20 psia and 40°F to 120 psia and 340°F. Determine (a) n, (b) AU and AH, (c) AS, (d) Q, (e) SpdV, (f) - SVdp. (g) If the process is steady flow during which AK = 0, what is W?. What is AK if W, = 0? (h) What is the work for a nonflow process?arrow_forward
- 1. During a polytropic process, 10 lb of an ideal gas, whose R = 40 ft.lb/lb.R and c = 0.25 Btu/lb.R, changes state from 20 psia and 40°F to 120 psia and 340°F. Determine (a)n, (b) AU and AH, (c) AS, (d) Q, (e) SpdV, (f) - SVdp. (g) If the process is steady flow during which AK = 0, what is W?. What is AK if W, = 0? (h) What is the work for a nonflow process? n = 1.356 AU= 595.8 Btu AH = 750 Btu -SVdp = -587.6 Btu AS = 0.2543: Btu OR Q = 162.3 Btu pdv = 433.3 Btuarrow_forwardwith solutionarrow_forwardA vessel of volume 1 m3 initially contains one percent by volume saturated liquid water and the rest saturated vapour at 1 bar. How much heat is to be supplied so that the vessel gets filled with vapour? Take data from steam tables. Answer= 195,814 Jarrow_forward
- Determine the volume, in ft^3, of 2 lb of a two‐phase liquid–vapor mixture of Refrigerant 134A at 48°F with a quality of 50%. What is the pressure, in lbf/in^2?arrow_forwardA spring-loaded piston-cylinder device contains of carbon dioxide. Initially, the spring has no force on the piston and , , . Heat is transferred to the gas, causing the piston to rise and to compress the spring. At the state 2, , . The gas is an ideal gas. (2)What's the value of ______in kPa?arrow_forwardNeed help with these two homework problems 1) A tank contains a two-phase liquid–vapor mixture of Refrigerant 22 at 8 bar. The mass of saturated liquid in the tank is 25 kg and the quality is 30%. Determine the volume of the tank, in m3, and the percentage of the total volume occupied by saturated vapor. 2) One kilogram of water contained in a piston–cylinder assembly, initially saturated vapor at 100 kPa, is condensed at constant pressure to saturated liquid. Consider an enlarged system consisting of the water and enough of the nearby surroundings that heat transfer occurs only at the ambient temperature of 25oC. Assume the state of the nearby surroundings does not change during the process, and ignore kinetic and potential energy effects. For the enlarged system, determine the heat transfer, in kJ, and the entropy production, in kJ/K.arrow_forward
- Using the steam tables, given a 0.085-m3 drum contains with wet steam at 371.5oC, (a) find the respective masses of the saturated vapor and saturated liquid in the mixture if they occupy equal volume. (b) find the respective volumes of the saturated liquid and saturated vapor in the mixture if their masses are equal.arrow_forwardSuperheated water at 1 MPa and 300 C is allowed to cool at constant volume until the temperature drops to 100 C. At the final state, determine the pressure in bar, the quality, and the amount of heat rejected in kJ/kg. Select one: a. 5.758 bar, 0.356, 596.82 kJ/kg b. 1.014 bar, 0.153, -2053.5kJ/kg c. 5.758 bar, 0.856, -922.82 kJ/kg d. 6.758 bar, 0.356, -1100.82 kJ/kgarrow_forward(25%) Q2. It includes wet vapor of R717 with a quality of 0.2 at a temperature of 15°C in a frictionless and well insulated piston-cylinder system shown in Fig. 2. Refrigerant is mixed with a propeller and initially occupies a volume of 5 L. When the pressure inside the cylinder reaches 800 kPa, the pin holding the cylinder will be broken and the propeller will stop, simultaneously. The piston moves upward after breaking the pin up to the point where equilibrium condition is obtained. Refrigerant is at saturated condition and a temperature of -15°C when the system reaches thermodynamic equilibrium. Calculate (a) the work done by the propeller, (b) The work done by the Fig. Q2 Piston- refrigerant after the pin is broken, and (c) the final volume of the refrigerant, (d) the entropy change of the refrigerant, (e) the entropy generation through this process. R717 cylinder systemarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
First Law of Thermodynamics, Basic Introduction - Internal Energy, Heat and Work - Chemistry; Author: The Organic Chemistry Tutor;https://www.youtube.com/watch?v=NyOYW07-L5g;License: Standard youtube license