Question
Chapter 8, Problem 8.6.2P
To determine
(a)
The available shear strength of the connection based on load resistance and factor design.
To determine
(b)
The flexural strength of the member based on load resistance and factor design.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Solve
An ISA 125 x 75 x 8 is welded with the flange of a
column ISHB 300. The bracket carries a factored
load of 75 kN at a distance of 38 mm as shown in
figure. Design the connection. Use Fe410 grade
steel. Field weld is used.
250
125
125
ISHB 300
38 75kN
300
Flange width of ISHB 300 = 250 mm.
-ISA 125 x 75 x 8
Five M20 8.8/ bolts are used in the connection between a beam and a column.
Both sides of the cleat plate are welded to column using fillet weld (Manual metal arc AS4855 B-E43XX) with size of 5 mm. The design force transferred from beam to column is 300 kN. The cleat plate has thickness of 12 mm, fy = 300 MPa, and fü = 360 MPa. Determine the unit stress sustained by the weld
Determine the maximum factored load P, that can be carried by the connection shown in the Figure P7. 1. The weld is 6 mm fillet weld. All structural steel is A36. E70 electrode is used
Chapter 8 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 8 - Prob. 8.2.1PCh. 8 - Prob. 8.2.2PCh. 8 - A plate is used as a bracket and is attached to a...Ch. 8 - Prob. 8.2.4PCh. 8 - Prob. 8.2.5PCh. 8 - Prob. 8.2.6PCh. 8 - Prob. 8.2.7PCh. 8 - Prob. 8.2.8PCh. 8 - Prob. 8.2.9PCh. 8 - Prob. 8.2.10P
Ch. 8 - Prob. 8.2.11PCh. 8 - Prob. 8.2.12PCh. 8 - Prob. 8.2.13PCh. 8 - Prob. 8.3.1PCh. 8 - Prob. 8.3.2PCh. 8 - Prob. 8.3.3PCh. 8 - Prob. 8.3.4PCh. 8 - Prob. 8.3.5PCh. 8 - Prob. 8.3.6PCh. 8 - Prob. 8.3.7PCh. 8 - Prob. 8.3.8PCh. 8 - Prob. 8.3.9PCh. 8 - Prob. 8.3.10PCh. 8 - Use an elastic analysis and determine the maximum...Ch. 8 - Use an elastic analysis and determine the maximum...Ch. 8 - Use an elastic analysis and determine the maximum...Ch. 8 - Prob. 8.4.4PCh. 8 - Prob. 8.4.5PCh. 8 - Prob. 8.4.6PCh. 8 - Use an elastic analysis and compute the extra load...Ch. 8 - Use an elastic analysis and compute the extra load...Ch. 8 - Prob. 8.4.9PCh. 8 - Prob. 8.4.10PCh. 8 - Prob. 8.4.11PCh. 8 - Prob. 8.4.12PCh. 8 - Prob. 8.4.13PCh. 8 - Prob. 8.4.14PCh. 8 - Prob. 8.4.15PCh. 8 - Prob. 8.4.16PCh. 8 - Prob. 8.4.17PCh. 8 - Prob. 8.4.18PCh. 8 - a. Use LRFD and design a welded connection for the...Ch. 8 - Prob. 8.4.20PCh. 8 - Prob. 8.5.1PCh. 8 - Prob. 8.5.2PCh. 8 - Prob. 8.5.3PCh. 8 - Prob. 8.5.4PCh. 8 - Prob. 8.5.5PCh. 8 - Prob. 8.6.1PCh. 8 - Prob. 8.6.2PCh. 8 - Prob. 8.6.3PCh. 8 - Prob. 8.6.4PCh. 8 - Prob. 8.7.1PCh. 8 - Prob. 8.7.2PCh. 8 - Prob. 8.7.3PCh. 8 - Prob. 8.8.1PCh. 8 - Prob. 8.8.2PCh. 8 - Prob. 8.8.3PCh. 8 - Prob. 8.8.4P
Knowledge Booster
Similar questions
- Determine the adequacy of the hanger connection in Figure P7.8-2 Account for prying action. a. Use LRFD. b. Use ASD.arrow_forwardThe welded frame beam connection consists of the framing angle 100 x 75 x12.5mm and the column W12 x 72. The welds are 9mm fillet welds made with E70 electrodes. All members are A36 steel. 12.5 mm a.) Determine Pu base on the capacity of the welds. Use LRFD design Factors. W 12x72 Angular Section 75 m 18.75 18.75 Angular section Angular section 800arrow_forwardProblem 7: The load that will be applied to the connection shown has a live load - to - dead load ratio of 3.0. Investigate all limit states. All structural steel is A36, and the weld is a 1/4-inch fillet weld with E70 electrodes. Note that the tension member is a double-angle shape, and both of the angles are welded as shown. Use ASD. Determine the following. 5" 5" 2L5 X 32 X 5/16 LLBB -t = ³/8" Maximum service load that can be applied without exceeding the allowable capacity on yielding on gross area of the tension member (double angle). Maximum service load that can be applied without exceeding the allowable fracture on the net area of the tension member (double angle). Maximum service load that can be applied without exceeding the allowable block shear strength. Considering the weld metal and base metal strength, calculate the maximum service load that can be applied.arrow_forward
- A bolted connection shown is bolted with a A-325 bolts with an allowable shearing stress of 207 MPa. A-36 steel is used. The applied force "T" is equally divided among the bolts. Assume bolt hole diameter to be 3 mm bigger than bolt diameter. Diameter of bolt is 20 mm. T/2 T T/2 10 mr 10 mm T/2 300 mm T/2 Determine the capacity of the connection if shearing governs in kN. A 1548.58 B 1170.56 1290.62 D 1439.25 000arrow_forwardFrom the preceding problem, determine the ultimate tensile force P. that the bolted connection could carry against tensile rupture in the net section. Use A- 50 steel and LRFD.arrow_forwardProblem 5: The lap connection shown consists of a PL1/2"X3" plate connected to a ½ in gusset plate with ¼" longitudinal fillet welds as indicated. The plates are A36 steel and the electrodes are E70XX. Calculate the length L (in) of the connection to develop the full capacity of the plate. Hint: The full capacity of the plate will depend on the governing strength of the tension member. Neglect block shear. Use ASD 6" x 1/2" P [ T L 1/4 1/4 E70 - 13²x P 3" x 1/2"arrow_forward
- A welded bracket connection is shown in figure. It supports a factored load of 150 kN at a distance of 120 mm from the face of column. Design the fillet weld on two sides. Grade of steel = Fe410, f. = 250 MPa. y 120 mm P₁ = 150 kN Fillet weld t = 12 mmarrow_forwardSOLVE FOR1 HRarrow_forwardSee image below. Five M16 8.8/s bolts are used in the connection between a beam and a column. Both sides of the cleat plate are welded to column using fillet weld (Manual metal arc AS4855 B- E43XX) with size of 6 mm. The design force transferred from beam to column is 250 kN. The cleat plate has thickness of 12 mm, fy = 300 MPa, and fu- 360 MPa. Determine the unit stress sustained by the weld (in MPa, keep 1 decimal place). 8.8/5 -360UB56.7 300 Plus 360 So 7°arrow_forward
- The details of an end bearing stiffener are shown in Figure . The stiffener plates are 9⁄16-inch thick, and the web is 3⁄16-inch thick. The stiffeners are clipped 1⁄2 inch to provide clearance for the flange-to-web welds. All steel is A572 Grade 50. a. Use LRFD and determine the maximum factored concentrated load that can be supported. b. Use ASD and determine the maximum service concentrated load that can be supported.arrow_forwardAn L6 x 4 x 1⁄2 is used in a seated beam connection, as shown in Figure . It must support a service load reaction of 5 kips dead load and 10 kips live load. The angles are A36 and the column is A992. E70XX electrodes are to be used. What size fillet welds are required for the connection to the column flange?arrow_forwardExplain pleasearrow_forward