Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN: 9781337094740
Author: Segui, William T.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 8, Problem 8.2.12P
To determine
(a)
The maximum factored load using LRFD by ultimate strength method.
To determine
(b)
The maximum factored load using ASD by ultimate strength method.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The bolt group shown in Figure P consists of 3⁄4inchdiameter, Group A bearingtype bolts in single shear. Assuming that the bearing strength is adequate, use the tables in Part 7 of the Manual to determine: a. The maximum permissible factored load for LRFD. b. The maximum permissible service load for ASD.
5) Calculate P the allowable tensile load for the butt joint shown. Each A325-N
high-strength bolt has a diameter of 0.9 inches. The plates are made of ASTM A36
steel.
If the applied load is 200 kips, is this connection adequate? If not, what needs to be
changed so that this connection can handle an applied load of 200 kips?
P-
ФФ
P
!
12"x "
P.
P.
4. An UPE 300 is to be used as a tension member and it is bolted to a 10mm thick gusset plate with bearing type
8-M20 8.8 bolts as shown in the figure below.
a. Check all spacing and edge distance requirements.
b. Compute the allowable tensile strength of the channel UPE 300. Don't consider shear strength of the bolts and bearing strength of the bolt holes.
[all dimensions are in mm]
Material both for gusset plate and UPE 300:
S275 F-275N/mm² Fu=430N/mm²
UPE 300
Ag = 5660 mm²
tw 9.5 mm
x = 28.9 mm
70
160
70
+
10mm thick gusset plate
+50+ 80
-80-80-50
o
+50+80 -80 80-50
UPE 300
Chapter 8 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 8 - Prob. 8.2.1PCh. 8 - Prob. 8.2.2PCh. 8 - A plate is used as a bracket and is attached to a...Ch. 8 - Prob. 8.2.4PCh. 8 - Prob. 8.2.5PCh. 8 - Prob. 8.2.6PCh. 8 - Prob. 8.2.7PCh. 8 - Prob. 8.2.8PCh. 8 - Prob. 8.2.9PCh. 8 - Prob. 8.2.10P
Ch. 8 - Prob. 8.2.11PCh. 8 - Prob. 8.2.12PCh. 8 - Prob. 8.2.13PCh. 8 - Prob. 8.3.1PCh. 8 - Prob. 8.3.2PCh. 8 - Prob. 8.3.3PCh. 8 - Prob. 8.3.4PCh. 8 - Prob. 8.3.5PCh. 8 - Prob. 8.3.6PCh. 8 - Prob. 8.3.7PCh. 8 - Prob. 8.3.8PCh. 8 - Prob. 8.3.9PCh. 8 - Prob. 8.3.10PCh. 8 - Use an elastic analysis and determine the maximum...Ch. 8 - Use an elastic analysis and determine the maximum...Ch. 8 - Use an elastic analysis and determine the maximum...Ch. 8 - Prob. 8.4.4PCh. 8 - Prob. 8.4.5PCh. 8 - Prob. 8.4.6PCh. 8 - Use an elastic analysis and compute the extra load...Ch. 8 - Use an elastic analysis and compute the extra load...Ch. 8 - Prob. 8.4.9PCh. 8 - Prob. 8.4.10PCh. 8 - Prob. 8.4.11PCh. 8 - Prob. 8.4.12PCh. 8 - Prob. 8.4.13PCh. 8 - Prob. 8.4.14PCh. 8 - Prob. 8.4.15PCh. 8 - Prob. 8.4.16PCh. 8 - Prob. 8.4.17PCh. 8 - Prob. 8.4.18PCh. 8 - a. Use LRFD and design a welded connection for the...Ch. 8 - Prob. 8.4.20PCh. 8 - Prob. 8.5.1PCh. 8 - Prob. 8.5.2PCh. 8 - Prob. 8.5.3PCh. 8 - Prob. 8.5.4PCh. 8 - Prob. 8.5.5PCh. 8 - Prob. 8.6.1PCh. 8 - Prob. 8.6.2PCh. 8 - Prob. 8.6.3PCh. 8 - Prob. 8.6.4PCh. 8 - Prob. 8.7.1PCh. 8 - Prob. 8.7.2PCh. 8 - Prob. 8.7.3PCh. 8 - Prob. 8.8.1PCh. 8 - Prob. 8.8.2PCh. 8 - Prob. 8.8.3PCh. 8 - Prob. 8.8.4P
Knowledge Booster
Similar questions
- The connection shown below uses 1-inch-diameter Group A bolts with the threads not in the shear plane. No slip is permitted. Both the tension member and the gusset plate are A36 steel. These bolts have not been added to distribute loads in the filler and two fillers are used. Use LRFD for solution. What is the design strength for block shear in kip? Express your answer in two decimal places. 1/2" thick Gusset Plate 3/8" thick 2" 3" 2" 2" 3" 3" 2"arrow_forwardAn angle section ISA 120 x 100 x 10 is shown in the figure. The bolts used are of diameter 20 mm. Find the block shear strength of the section if the minimum end distance and distance between the bolts provided is shown in the figure. [Use Fe410 grade of steel) 33 mm 50 mm 50 mm O------- unu o uuu osarrow_forwardThe connection shown below uses 1-inch-diameter Group A bolts with the threads not in the shear plane. No slip is permitted. Both the tension member and the gusset plate are A36 steel. These bolts have not been added to distribute loads in the filler and two fillers are used. Use LRFD for solution. What is the design strength for block shear in kip? Express your answer in two decimal places. 2" 3" 2" 1/2" thick Gusset Plate O 2" 3" 3" 2" 3/8" thick Parrow_forward
- The tension member shown is a PL 5/8 x 10, and the steel is A36. The bolts are 7/8-inch in diameter. a. Determine the design strength for LRFD. b. Determine the allowable strength for ASD. 2" 2" -|-|- |-|-|- -| 3 die einheitliche O O O OO Oarrow_forwardPLEASE ANSWER ALL ASAParrow_forwardA 2L5 x 3 x 4 LLBB of A709 Grade 36 steel is connected to a gusset plate PL x 7 of A36 steel with -in-diameter bolts as shown in the Figure. What is the tensile capacity for LRFD. 2-[ 2L5x3x4 LLBB A-in-diameter bolts 1.5arrow_forward
- The tension member shown in the figure is a PL1/⁄2”X8” of ASTM A36 steel. The member is connected to a gusset plate with inch diameter bolts. It is subjected to the dead and live loads shown. Does this member have enough strength? Assume that . a) Per LRFD b) Per ASD 00 O D=95k L=9k PL 12 x 8arrow_forwardThe connection shown below uses 1-inch-diameter Group A bolts with the threads not in the shear plane. No slip is permitted. Both the tension member and the gusset plate are A36 steel. These bolts have not been added to distribute loads in the filler and two fillers are used. Use LRFD for solution. What is the design strength for tension on gross area in kip? Express your answer in two decimal places. 1/2" thick Gusset Plate 3/8" thick 2" 3" 2" 2" 3" 3" 2" P.arrow_forwardHi! Please answer this question. Thank you!arrow_forward
- I vll upvote.....Asap plzarrow_forwardThe tension member shown is a PL 5/8 x 10, and the steel is A36. The bolts are 7/8-inch in diameter. a. Determine the design strength for LRFD. b. Determine the allowable strength for ASD. Tühitinin 2" 2" + 32 | 3² | O O O O OO Oarrow_forwardThe connection shown below uses 1-inch-diameter Group A bolts with the threads not in the shear plane. No slip is permitted. Both the tension member and the gusset plate are A36 steel. These bolts have not been added to distribute loads in the filler and two fillers are used. Use LRFD for solution. What is the design strength for tension on net area in kip? Express your answer in two decimal places.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning