Fundamentals of Heat and Mass Transfer
7th Edition
ISBN: 9780470917855
Author: Bergman, Theodore L./
Publisher: John Wiley & Sons Inc
expand_more
expand_more
format_list_bulleted
Question
Chapter 11, Problem 11.75P
a.
To determine
The power required by the motor.
B.
To determine
To calculate the refrigerator in each segment and the power required by the motor?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A manufacturer conducted an experiment for an
evaporator capacity 507 kW cooling and designed for
high COP of 1.8 when using lithium bromide plus
water in an absorption refrigeration system. The
evaporator operates 20 C, condenser 40 C &
absorber 45 C supplying 1.4 kg/s of water plus lithium
bromide solution to the generator. For a condenser
size of 694 kW,
determine:
Heat provided by the generator
&
absorber capacity in kW
(b) Determine the cooling load (q₁), heat rejection (q) and actual compressor work input (w) per unit mass in kJ/kg. .
C. (c) Calculate the coefficient of performance (COP) of this actual refrigeration cycle and compare it with the COP of a reversed Carnot cycle for refrigeration if used under the same inside and outside amblent temperatures.
Provide correct explanation
Chapter 11 Solutions
Fundamentals of Heat and Mass Transfer
Ch. 11 - In a fire-tube boiler, hot products of combustion...Ch. 11 - A shell-and-tube heat exchanger is to heat an...Ch. 11 - A steel tube (k=50W/mK) of inner and outer...Ch. 11 - A heat recovery device involves transferring...Ch. 11 - A novel design for a condenser consists of a tube...Ch. 11 - The condenser of a steam power plant...Ch. 11 - Thin-walled aluminum tubes of diameter D = 10mmare...Ch. 11 - A tinned-tube, cross-how heat exchanger is to use...Ch. 11 - Water at a rate of 45,500kg/h is heated from 80...Ch. 11 - A novel heat exchanger concept consists of a...
Ch. 11 - Prob. 11.12PCh. 11 - A process fluid having a specific heat of...Ch. 11 - A shell-and-tube exchanger (two shells, four tube...Ch. 11 - Consider the heat exchanger of Problem 11.14....Ch. 11 - The hot and cold inlet temperatures to a...Ch. 11 - A concentric tube heat exchanger of length L = 2 m...Ch. 11 - A counterflow, concentric tube heat exchanger is...Ch. 11 - Consider a concentric tube heat exchanger with an...Ch. 11 - A shell-and-tube heat exchanger must be designed...Ch. 11 - A concentric tube heat exchanger for cooling...Ch. 11 - A counterflow, concentric tube heat exchanger used...Ch. 11 - An automobile radiator may be viewed as a...Ch. 11 - Hot air for a large-scale drying operation is to...Ch. 11 - In a dairy operation, milk at a flow rate of 250...Ch. 11 - The compartment heater of an automobile...Ch. 11 - A counterflow, twin-tube heat exchanger is made...Ch. 11 - Consider a coupled shell-in-tube heat exchange...Ch. 11 - For health reasons, public spaces require the...Ch. 11 - A shell-and-tube heat exchanger (1 shell pass, 2...Ch. 11 - Saturated water vapor leaves a steam turbine at a...Ch. 11 - The human brain is especially sensitive to...Ch. 11 - Prob. 11.47PCh. 11 - A plate-tin heat exchanger is used to condense a...Ch. 11 - In a supercomputer, signal propagation delays...Ch. 11 - Untapped geothermal sites in the United States...Ch. 11 - A shell-and-tube heat exchanger consists of 135...Ch. 11 - An ocean thermal energy conversion system is...Ch. 11 - Prob. 11.55PCh. 11 - Prob. 11.56PCh. 11 - The chief engineer at a university that is...Ch. 11 - A shell-and-tube heat exchanger with one shell...Ch. 11 - Prob. 11.59PCh. 11 - Prob. 11.60PCh. 11 - Prob. 11.61PCh. 11 - Prob. 11.62PCh. 11 - A recuperator is a heat exchanger that heats air...Ch. 11 - Prob. 11.64PCh. 11 - Prob. 11.65PCh. 11 - A cross-flow heat exchanger consists of a bundle...Ch. 11 - Exhaust gas from a furnace is used to preheat the...Ch. 11 - Prob. 11.68PCh. 11 - A liquefied natural gas (LNG) regasification...Ch. 11 - Prob. 11.70PCh. 11 - A shell-and-tube heat exchanger consisting of...Ch. 11 - Prob. 11.73PCh. 11 - The power needed to overcome wind and friction...Ch. 11 - Prob. 11.75PCh. 11 - Consider a Rankine cycle with saturated steam...Ch. 11 - Consider the Rankine cycle of Problem 11.77,...Ch. 11 - Prob. 11.79PCh. 11 - Prob. 11.80PCh. 11 - Hot exhaust gases are used in a...Ch. 11 - Prob. 11.84PCh. 11 - Prob. 11.90PCh. 11 - Prob. 11S.1PCh. 11 - Prob. 11S.2PCh. 11 - Prob. 11S.3PCh. 11 - Solve Problem 11.15 using the LMTD method.Ch. 11 - Prob. 11S.5PCh. 11 - Prob. 11S.6PCh. 11 - Prob. 11S.8PCh. 11 - Prob. 11S.10PCh. 11 - Prob. 11S.11PCh. 11 - A cooling coil consists of a bank of aluminum...Ch. 11 - Prob. 11S.17P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- If 14 gpm of water is flowing through an open-loop heat pump with a temperature difference of 7F, how much heat in Btu/h is being absorbed or rejected in the heat pump? Show all work and units.arrow_forwardThe function of the pressure tank in an open-loop, geo-thermal heat pump well system is to prevent the well pump from _____.arrow_forwardSolve the problem correctly. Looking for genuine Solution.arrow_forward
- An air-conditioning absorption system has an evaporator capacity of 350 kW with a COP of 0.90 operating at a temperature of 25 C with a condensing temperature of 35 C. The same cooling tower was used to reject the heat from the condenser and the absorber operating 45 C & providing 1 kg/s of water plus lithium bromide solution to the generator. Consider the heat rejection ratio of condenser to evaporator is 1.05, Determine the following: 1. Heat given by the generator & the size of condenser in kW 2. Leaving condenser & evaporator enthalpies & the mass of refrigerant water flowing from the generator to the condenser then to the evaporator & to the absorber (using evaporator heat balance). 3. Weight of lithium bromide in kg/s, concentration in percent & enthalpy from the absorber to the generator in kJ/kg 4. Enthalpy from the generator to condenser in kJ/kg (using condenser heat balance) & concentration in percent & enthalpy from generator to absorber…arrow_forwardReinneil Law-ay Active Now 7. (a) Compute the possible maximum efficiency of a heat engine operating between the temperature limits of 147*C and 698*C. (b) A refrigerator has COP of 6. How much work must be supplied to the refrigerator in order to remove 45 cal of heat from its interion? •.. More Edit IIarrow_forwardRefrigeration Systemarrow_forward
- Required information Problem 05.087- Heat exchanger The evaporator of a refrigeration cycle is basically a heat exchanger in which a refrigerant is evaporated by absorbing heat from a fluid. Refrigerant-22 enters an evaporator at 200 kPa with a quality of 22 percent and a flow rate of 2.65 m³/h. R-22 leaves the evaporator at the same pressure superheated by 5°C. The refrigerant is evaporated by absorbing heat from air whose flow rate is 0.745 kg/s. The properties of R-22 at the inlet and exit of the condenser are h₁ 220.2 kJ/kg, V₁ = 1.005 kJ/kg °C. 0.0253 m³/kg, and h₂ 398.0 kJ/kg. The specific heat of air is taken as Problem 05.087.a - Heat exchanger Determine the rate of heat absorbed from the air. The rate of heat absorbed from the air is KWarrow_forwardA manufacturer conducted an experiment for an evaporator capacity 500 kW cooling and designed for high COP of 2 when using lithium bromide plus water in an absorption refrigeration system. The evaporator operates 20 C, condenser 40 C & absorber 45 C supplying 1.4 kg/s of water plus lithium bromide solution to the generator. For a condenser size of 650 kW, determine:Ethalphy of the refrigerant leaving the Evaporator in kJ/kgAnswer in one decimal place(s)arrow_forwardIn a meat processing plant, it is required to cool 1500 kg of beef whose specific heataverage is 3.14 kJ/kg-°C to lower its temperature from 39 °C to 2 °C in 14 hours. It is required to estimate theenergy requirements necessary for meat cooling capacity, assuming that the cooling systemRefrigeration operates on an ideal vapor compression refrigeration cycle. A refrigeration unit is chosenwith refrigerant 134a with a condenser pressure of 1.4 MPa and an evaporator pressure of 240 kPa.Assume that the refrigerant enters the compressor as a saturated vapor and leaves the condenser as a saturated liquid.Calculate:a) The COPR or CDFR,b) The mass flow of the refrigerantc) The energy dissipated into the atmosphered) The cost of annual electrical energy, if the plant will operate with a load factor (FC) of 85% (100%-FC =8760 h/year). Consider the unit cost of electrical energy of $2.6 per kWh and the efficiency of the system90% motor-compressor.arrow_forward
- A new parabolic dish solar concentrator is being developed to supply electricity to a small remote community. The system operates with a Stirling engine connected to two heat reservoirs HR₁ and HR₂ as shown in Fig. Concentrated solar radiation Q˙ₛᵤₙ=200kW maintains HR₁ at constant temperature Tₕᵣ,₁=700℃, and a high performance heat sink device maintains HR₂ at temperature Tₕᵣ,₂=25℃. After some time of operation, an engineer working on the project realizes that the engine power output is performing below design specifications and only provides a power output of 120kW. After inspecting the system, they discover a contact resistance that causes the thermal communication between the two heat reservoirs and the engine to be imperfect in the sense that a finite temperature difference is required to establish heat transfer between each of the heat reservoirs and the engine. Assuming the engine itself is internally reversible, estimate the rate of entropy generation in the engine’s…arrow_forwardA new parabolic dish solar concentrator is being developed to supply electricity to a small remote community. The system operates with a Stirling engine connected to two heat reservoirs HR₁ and HR₂ as shown in Fig. Concentrated solar radiation Q˙ₛᵤₙ=200kW maintains HR₁ at constant temperature Tₕᵣ,₁=700℃, and a high performance heat sink device maintains HR₂ at temperature Tₕᵣ,₂=25℃. After some time of operation, an engineer working on the project realizes that the engine power output is performing below design specifications and only provides a power output of 120kW. After inspecting the system, they discover a contact resistance that causes the thermal communication between the two heat reservoirs and the engine to be imperfect in the sense that a finite temperature difference is required to establish heat transfer between each of the heat reservoirs and the engine. Sketch the cycle on a T-s diagram and include the temperatures of the heat reservoirs in your sketch. Calculate the…arrow_forwardA manufacturer conducted an experiment for an evaporator capacity 500 kW cooling and designed for high COP of 2 when using lithium bromide plus water in an absorption refrigeration system. The evaporator operates 20 C, condenser 40 C & absorber 45 C supplying 1.4 kg/s of water plus lithium bromide solution to the generator. For a condenser size of 650 kW, determine:Ethalphy of the refrigerant entering the Evaporator in kJ/kg Answer in two decimal placesarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Heat Transfer – Conduction, Convection and Radiation; Author: NG Science;https://www.youtube.com/watch?v=Me60Ti0E_rY;License: Standard youtube license