Applied Fluid Mechanics (7th Edition)
7th Edition
ISBN: 9780132558921
Author: Robert L. Mott, Joseph A. Untener
Publisher: PEARSON
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 11, Problem 11.49PP
For the system described in Problem 11.47, and using the tube size found in that problem, compute the expected volume flow rate through the tube if the pressure above the fluid in the large tank at A is
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A piping system is to be installed at place where the pump will transfer the fluid from tank A to tank B. There are two suggested piping designs available to carry the fluid efficiently. Compute and determine which of the available piping arrangement will experience the less pumping powerwith given flow conditions. Discuss the results.
Flow conditions are same for both type of designs and given as: Pipe material: stainless steel Volume flow rate: 40 L/sec Assume the working fluid is water at standard atmosphere temperature and both tanks areopen to atmosphere. Pipe inlet is sharp-edged and bends are sharped without vanes. Elevations are as ?? = ?? ? and ?? = ?? ?
10.4
Determine the pressure difference between two points on either side of a sudden enlargement from a tube with a 2-in ID to one with a 6-in ID when the velocity of flow of water is 4 ft/s in the smaller tube.
10.5
Determine the pressure difference for the conditions in Problem 10.4 if the enlargement is gradual with a cone angle of 15.
Answer: p1-p2= -0.0891 psi
Compute the flow rate of fluid if it is moving with the velocity of 20 m/s through a tube of
diameter 0.03 m.
Chapter 11 Solutions
Applied Fluid Mechanics (7th Edition)
Ch. 11 - Water at 10C flows from a large reservoir at the...Ch. 11 - For the system shown in Fig. 11.14, kerosene (...Ch. 11 - Figure 11.15 shows a portion of a hydraulic...Ch. 11 - Figure 11.16 shows part of a large hydraulic...Ch. 11 - Oil is flowing at the rate of 0.015m3/s in the...Ch. 11 - For the system shown in Fig. 11.18, calculate the...Ch. 11 - A liquid refrigerant flows through the system,...Ch. 11 - Water at 100F is flowing in a 4-in Schedule 80...Ch. 11 - A hydraulic oil is flowing in a drawn steel...Ch. 11 - In a processing plant, ethylene glycol at 77F is...
Ch. 11 - Water at 15C is flowing downward in a vertical...Ch. 11 - Turpentine at 77F is flowing from A to B in a 3...Ch. 11 - ]11.13 A device designed to allow cleaning of...Ch. 11 - Kerosene at 25C is flowing in the system shown in...Ch. 11 - Water at 40C is flowing from A to B through the...Ch. 11 - Oil with a specific gravity of 0.93 and a dynamic...Ch. 11 - Determine the required size of new Schedule 80...Ch. 11 - What size of standard hydraulic copper tube from...Ch. 11 - Water at 60F is to flow by gravity between two...Ch. 11 - The tank shown in Fig. 11.24 is to be drained to a...Ch. 11 - Figure 11.25 depicts gasoline flowing from a...Ch. 11 - For the system in Fig. 11.26, compute the pressure...Ch. 11 - For the system in Fig. 11.26, compute the total...Ch. 11 - For the system in Fig. 11.26 specify the size of...Ch. 11 - A manufacturer of spray nozzles specifies that the...Ch. 11 - Specify the size of new Schedule 40 steel pipe...Ch. 11 - Refer to Fig. 11.27. Water at 80C is being pumped...Ch. 11 - For the system shown in Fig. 11.27 and analyzed in...Ch. 11 - In a water pollution control project, the polluted...Ch. 11 - Repeat Problem 11.29, but use a 3-in Schedule 40...Ch. 11 - Water at 10C is being delivered to a tank on the...Ch. 11 - If the pressure at point A in Fig. 11.29 is 300...Ch. 11 - Change the design of the system in Fig. 11.29 to...Ch. 11 - It is desired to deliver 250 gal/min of ethyl...Ch. 11 - For the system shown in Fig. 11.30, compute the...Ch. 11 - Repeat Problem 11.35, but consider the valve to be...Ch. 11 - Repeat Problem 11.35, but consider the valve to be...Ch. 11 - Figure 11.31 depicts a DN 100 Schedule 40 steel...Ch. 11 - Repeat Problem 11.38 but replace the globe valve...Ch. 11 - Repeat Problem 11.38 but use a DN 125 Schedule 40...Ch. 11 - Repeat Problem 11.38, but replace the globe valve...Ch. 11 - It is desired to drive a small,...Ch. 11 - Figure 11.32 shows a pipe delivering water to the...Ch. 11 - Repeat Problem 11.43, except consider that there...Ch. 11 - A sump pump in a commercial building sits in a...Ch. 11 - For the system designed in Problem 11.45, compute...Ch. 11 - Figure 11.33 shows a part of a chemical processing...Ch. 11 - For the system described in Problem 11.47, and...Ch. 11 - For the system described in Problem 11.47, and...Ch. 11 - For the system described in Problem 11.47, and...Ch. 11 - Analyze the system shown in Fig. 11.11 with...Ch. 11 - Create a program or a spreadsheet for analyzing...Ch. 11 - Create a program or a spreadsheet for determining...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Using the appropriate equation from Table 4.3, calculate the wall sheer stress (in Pa) in a tube 5 mm in diameter with a flow rate of 1.3 Liters/minute. You may assume the fluid is Newtonian and has a viscosity of 1.9 cP. Do not include the unit label in you answer, only the numeric value.arrow_forwardA horizontal 150 mm diameter pipe gradually reduces its section to 55 diameter, subsequently enlarging into 150 mm section. The pressure in the 150-mm pipe at a point just before entering the reducing section is 147 kPa and in the 55 mm section at the end of the reducer, the pressure is 79 kPa. If 657 mm of head is lost between the points where the pressure are known compute the rate of flow in L/s of water through the pipe.arrow_forwardsolve for ha2 in m, thanksarrow_forward
- Please compute the Reynolds number of an oil (0.8 specific gravity, 0.8 cp viscosity) flowing in a pipe of 1- inch diameter at a velocity of 6 ft/s. Is this flow laminar or turbulent?arrow_forwardThe pressure loss through the pipe and the minimum power required to overcome the resistance to flow.arrow_forwardBased on the layout of the water supply system, as show in Figure 1, the pressure, in psi, is estimated be 46 at the faucet in the and floor of the residential building. Consider flow through the delivery pipe, Q = 1.50 cfs and diameter of the pipe, D = 2.65 inch with e = 0.015 inch. Ingore the minor pressure losses and use the following formulae to calculate the major pressure losses. The additional power in hp required to provide the recommended pressure of 58 psi at the building is nearly. Assume f = 0.0175. Use g = 62.4 lb/f3 for water. Water temperature is 20°C (68°F).arrow_forward
- A perfect venture with throat diameter of 1.8 inches is placed horizontally in a pipe with a 5 in inside diameter. 80 lb of water flow through the pipe each second. What is the difference between the pipe and venture throat static pressure?arrow_forwardSaturated water at 310K is being pumped from a tank to an elevated tank at the rate of 7L/s. All of the piping is in 5-in. schedule 40 steel pipe. If the 2 fittings used is 90° ell standard long radius, The pump has an efficiency of 80%. Calculate the kW power needed for the pump. Calculate the total friction losses in kJ/kg.arrow_forwardProblem 5: Given a Crucible with a base diameter (Din)of 8 mm and the length (L) of the attached half pipe is 10 mm and the height (H) of the crucible is 16 mm. If initially the Crucible is filled to the half with water and we tilt or incline this crucible with angle a until it begins to flow out of the shown structure. Calculate the volume flowrate of the water and the time to be empty. Note: if there is any missing parameter or information you can Assume it and solve the problem. Din Upright position tilted positionarrow_forward
- Answer should be in psi.arrow_forward4. A special oil is to be used in an absorption tower. The preliminary design of the unit requires the oil to be pumped from an open tank with a 10 ft liquid level above the floor and forced through 150 ft of 3 inches schedule 40 pipe with a ball check valve and 5 elbows into the top of a tower 30 ft above the floor. The operating pressure in the tower is to be 52 psig and the oil requirement is estimated at 50 gpm. The viscosity of the oil 15 cP and its density is 53.5 Ibm/ft. Assuming the pumping outfit operates with an overall efficiency of 60%, what horsepower input will be required for the pump motor?arrow_forwardWater at 60F is flowing through a 3-inch inside diameter smooth horizontal pipe. If the Reynolds number is 353,000.Calculate the ratio of maximum velocity to average velocity.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Intro to Compressible Flows — Lesson 1; Author: Ansys Learning;https://www.youtube.com/watch?v=OgR6j8TzA5Y;License: Standard Youtube License