A plate-tin heat exchanger is used to condense a saturated refrigerant vapor in an air-conditioning system.The vapor has a saturation temperature of
(a) The condenser design is to be based on a nominal air inlet temperature of
(b) From the manufacturer of the heat exchangercore, it is also known that
Want to see the full answer?
Check out a sample textbook solutionChapter 11 Solutions
Fundamentals of Heat and Mass Transfer
Additional Engineering Textbook Solutions
Statics and Mechanics of Materials (5th Edition)
DeGarmo's Materials and Processes in Manufacturing
Fluid Mechanics Fundamentals And Applications
Engineering Mechanics: Statics
Applied Fluid Mechanics (7th Edition)
Vector Mechanics for Engineers: Statics, 11th Edition
- An air-cooled condenser has an h value of 30 W/m2-K based on the air-side area. The air-side heat transfer area is 190 m2 with air entering at 27°C and leaving at 40°C. If the condensing temperature is constant at 49°C, what is the air mass flow rate in kg/s? Let Cp(air) = 1.006 kJ/kg-K. Draw and label the temperature-flow diagram. Round off your answer to three (3) decimal places.arrow_forwardPlease calculate enthalpies and the heat of a condenser and evaporator. Thank youarrow_forwardA freon 12 waste water system operating at 5 °C suction temperature and a 40°C condensing temperature has an evaporator load 17.6 KW. If the condenser is selected for a 70°C water temperature rises, how many gpm must be circulated through the condenser? The following enthalpies have been found; condenser entrance =377 kJ/kg; exitA=238.5 kJ/kg; evaporator entrance =238.5 kJ/kg; exit = 253.6 kJ/kg.arrow_forward
- The food storage room requires a cooling system with a capacity of 10 tons of refrigeration that operates at an evaporator temperature of -17.8 ° C and a condenser temperature of 30.1 ° C. The refrigerant used is R-717 and the system operates in saturated conditions. Specifi :COP, Refrigerant flow rate ,Heat loss rate in condensesarrow_forwardA straight-condensing 10,000 kW turbine has a guaranteed steam rate of 5.90 kg/kW.hr when exhausting at 5.0 kPa. Exhaust steam enters the condenser at 92% quality, and it is estimated that fouling will decrease the overall coefficient by 30% during operation. Cooling water is available at 18 ℃, and for design purposes, 1 ½ in OD 16 BWG Brass tubes (thickness = 0.065 in, k=62 BTU/hrftF°.) are specified with 9 C° rise in cooling water, which circulates at 5 ft/s. Inside and outside film coefficients are hi=960 and ho=1474 BTU/hrft2F°. Design a condenser for this turbine, considering tube and boundary resistance as flat surfaces and neglecting any crossflow factor. Determine the followinga) Effective overall coefficient of heat transferb) Volume flow rate of cooling waterc) Number of tubes for single passd) Length of tubesarrow_forwardWater inter a condenser at a mass flow rate of (2.5 kg/s) and (21 kPa and 65 C), and exit with (h= 251.5 kJ/kg). Find: a) The mass flow rate of water flow at the exit section b) the rate of heat removed from the water in the condenser. From table: at T1-60-C & P1-21 kPa -hl=2423x10 J/kgarrow_forward
- A refrigeration system using R22 is to have a refrigerating capacity of 60 kW. The evaporating temperature is -5degC and condensing temperature of 35 deg-C. Determine the volume flow rate of the refrigerant at the inlet to the compressor, the power required by the compressor, and the fraction of vapor in the mixture at the entrance to the evaporator. Use the spreadsheet to solve this problem.arrow_forwardIn an ammonia refrigeration system, the pressure in the evaporator is 251 kPaa, and the ammonia at the evaporator entry is 0.1511 dry while at exit is 0.95 dryIf the rate of ammonia circulation is 4.56 kg / m * i * n , determine the refrigerating capacity of the system. Use the properties of ammonia from refrigerantstablearrow_forwardA Cascade refrigeration system using R-32 and a heat exchanger is operating an evaporator with a capacity of 6 tons at a temperature of -30°C. If the heat exchanger pressure is 0.80 MPa and the condensing temperature is 50°C, determine the COP and the refrigerating efficiency of the system. Draw the schematic diagram of the system and assume ideal conditions.arrow_forward
- Q6 Kindly answer correctly.Please show all the necessary stepsarrow_forwardBy taking the limit as DT2 DT1, show that when DT1 = DT2 for a heat exchanger, the DTlm relation reduces to DTlm = DT1 = DT2.arrow_forwardIn a hydrocarbon processing plant, Fluid A (cp = 4.31 kJ/kg-K) entering the tube side is used to heat Fluid B (cp = 2.05 kJ/kg-K) in a heat exchanger with an overall heat transfer coefficient of 150 W/m2.°C. Based on the information given in TABLE Q3, determine the outlet temperatures of Fluid A and Fluid B. If the surface area of the heat exchanger increases 30%, what would be the effect on outlet temperatures? Justify your answer with calculation. Comment your answer. TABLE Q3 Type of heat exchanger Mass flow Inlet Surface rate, kg/s temperature, °C area, A, m2 Fluid Fluid Fluid Fluid A в А B 3.0 5.5 150 20 150 Cross flow, both fluid unmixed 3.arrow_forward
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning