Fundamentals of Heat and Mass Transfer
7th Edition
ISBN: 9780470501979
Author: Frank P. Incropera, David P. DeWitt, Theodore L. Bergman, Adrienne S. Lavine
Publisher: Wiley, John & Sons, Incorporated
expand_more
expand_more
format_list_bulleted
Question
Chapter 11, Problem 11S.17P
To determine
To find the number of tube rows required to provide saturated steam.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A manufacturer conducted an experiment for an
evaporator capacity 507 kW cooling and designed for
high COP of 1.8 when using lithium bromide plus
water in an absorption refrigeration system. The
evaporator operates 20 C, condenser 40 C &
absorber 45 C supplying 1.4 kg/s of water plus lithium
bromide solution to the generator. For a condenser
size of 694 kW,
determine:
Heat provided by the generator
&
absorber capacity in kW
5. A counter-flow bank of boiler tubes has a total area of 900 sq ft and its overall efficiency of heat transfer is 13
Btu/hr-ft2-degF. Calculate the heat transferred if the log mean temperature difference is 1380 deg F.
a supply tank having 14m long and 1.7m diameter is used to store fuel oil with 34degree API at 110degree C. if the tank is used for diesel power plant consuming 62 kg/hr of fuel, determine the number of days the supply tank can hold continuous operation.
Chapter 11 Solutions
Fundamentals of Heat and Mass Transfer
Ch. 11 - In a fire-tube boiler, hot products of combustion...Ch. 11 - A shell-and-tube heat exchanger is to heat an...Ch. 11 - A steel tube (k=50W/mK) of inner and outer...Ch. 11 - A heat recovery device involves transferring...Ch. 11 - A novel design for a condenser consists of a tube...Ch. 11 - The condenser of a steam power plant...Ch. 11 - Thin-walled aluminum tubes of diameter D = 10mmare...Ch. 11 - A tinned-tube, cross-how heat exchanger is to use...Ch. 11 - Water at a rate of 45,500kg/h is heated from 80...Ch. 11 - A novel heat exchanger concept consists of a...
Ch. 11 - Prob. 11.12PCh. 11 - A process fluid having a specific heat of...Ch. 11 - A shell-and-tube exchanger (two shells, four tube...Ch. 11 - Consider the heat exchanger of Problem 11.14....Ch. 11 - The hot and cold inlet temperatures to a...Ch. 11 - A concentric tube heat exchanger of length L = 2 m...Ch. 11 - A counterflow, concentric tube heat exchanger is...Ch. 11 - Consider a concentric tube heat exchanger with an...Ch. 11 - A shell-and-tube heat exchanger must be designed...Ch. 11 - A concentric tube heat exchanger for cooling...Ch. 11 - A counterflow, concentric tube heat exchanger used...Ch. 11 - An automobile radiator may be viewed as a...Ch. 11 - Hot air for a large-scale drying operation is to...Ch. 11 - In a dairy operation, milk at a flow rate of 250...Ch. 11 - The compartment heater of an automobile...Ch. 11 - A counterflow, twin-tube heat exchanger is made...Ch. 11 - Consider a coupled shell-in-tube heat exchange...Ch. 11 - For health reasons, public spaces require the...Ch. 11 - A shell-and-tube heat exchanger (1 shell pass, 2...Ch. 11 - Saturated water vapor leaves a steam turbine at a...Ch. 11 - The human brain is especially sensitive to...Ch. 11 - Prob. 11.47PCh. 11 - A plate-tin heat exchanger is used to condense a...Ch. 11 - In a supercomputer, signal propagation delays...Ch. 11 - Untapped geothermal sites in the United States...Ch. 11 - A shell-and-tube heat exchanger consists of 135...Ch. 11 - An ocean thermal energy conversion system is...Ch. 11 - Prob. 11.55PCh. 11 - Prob. 11.56PCh. 11 - The chief engineer at a university that is...Ch. 11 - A shell-and-tube heat exchanger with one shell...Ch. 11 - Prob. 11.59PCh. 11 - Prob. 11.60PCh. 11 - Prob. 11.61PCh. 11 - Prob. 11.62PCh. 11 - A recuperator is a heat exchanger that heats air...Ch. 11 - Prob. 11.64PCh. 11 - Prob. 11.65PCh. 11 - A cross-flow heat exchanger consists of a bundle...Ch. 11 - Exhaust gas from a furnace is used to preheat the...Ch. 11 - Prob. 11.68PCh. 11 - A liquefied natural gas (LNG) regasification...Ch. 11 - Prob. 11.70PCh. 11 - A shell-and-tube heat exchanger consisting of...Ch. 11 - Prob. 11.73PCh. 11 - The power needed to overcome wind and friction...Ch. 11 - Prob. 11.75PCh. 11 - Consider a Rankine cycle with saturated steam...Ch. 11 - Consider the Rankine cycle of Problem 11.77,...Ch. 11 - Prob. 11.79PCh. 11 - Prob. 11.80PCh. 11 - Hot exhaust gases are used in a...Ch. 11 - Prob. 11.84PCh. 11 - Prob. 11.90PCh. 11 - Prob. 11S.1PCh. 11 - Prob. 11S.2PCh. 11 - Prob. 11S.3PCh. 11 - Solve Problem 11.15 using the LMTD method.Ch. 11 - Prob. 11S.5PCh. 11 - Prob. 11S.6PCh. 11 - Prob. 11S.8PCh. 11 - Prob. 11S.10PCh. 11 - Prob. 11S.11PCh. 11 - A cooling coil consists of a bank of aluminum...Ch. 11 - Prob. 11S.17P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Can you help me with question 2.arrow_forwardAn ammonia ice plant operates on simple saturation cycle at the following temperatures. Condensing temperature 40°C Evaporating temperature -15°C It produces 10 tons of ice per day at -5°C from water at 30°C. Determine: (a) Capacity of the refrigeration plant. (b) Mass flow rate of refrigerant. (c) Isentropic discharge temperature. (d) Compressor dimensions (bore and stroke) if its volumetric efficiency is assumed as 65%. The compressor is to run at 1400 rpm. Take stroke/ bore ratio (L/D) as 1.2. (e) Horsepower of the compressor if its adiabatic efficiency is taken as 85% and mechanical efficiency as 95%. (f) Theoretical and actual COP.arrow_forwardA CSP supercritical steam power plant using a concentrating collector arrayfor DSG (refer to Figure 8.12) is operating under the following conditions:• Plant electric power output Pel = 28 MW• Intensity of beam solar radiation incident on the concentrator apertureIbc = 798 W/m2• Aperture area of a single concentrator module Aap = 420 m2• Efficiency of the collector ηc = 0.7• Power plant thermal efficiency ηth = 0.39• Efficiency of the electric generator ηg = 0.97• HTF is water/steam• Superheated steam condition at the absorber outlet/turbine inlet:ps = 250 bars, ts = 600°C• Feedwater temperature at the absorber inlet = tw = 280°C Calculate (i) the power plant overall (electrical) efficiency, (ii) the thermal capacity of the power plant, (iii) the rate of useful heat output of aDSG collector module, (iv) the number of concentrator modules, and (v) the steam generation rate of the solar collector.arrow_forward
- A surface condenser serving a 50,000-kW steam turbo-generator unit receives exhaust steam at the rate of 196,000 kg/hr. Vacuum in condenser is 702 mmHg. Sea water SG=1.03 and Cp=0.93 Btu/lb-F is used for cooling enters at 29.5C and leaves at 37.5C. From the steam condenser design, manufacturer consider 950 Btu/lb of steam condensed as heat given up cooling water. Calculate the required quantity of cooling water in m3/s.arrow_forwardThe following is part of a power cycle; the purpose of this cycle is to generate work to run an electrical generator. R-410A is the working fluid. The turbine generates enough work to run the compressor and to send work to the electrical generator (Wnet). Determine the cycle efficiency.arrow_forwardQ16 Steam generated at a pressure of 600 kPa (abs), at a temperature of 500°C and at a rate of 10 kg/s from feedwater at 40°C. The fuel is a heavy fuel oil with relative density 0.98 and energy content 42.9 MJ/kg. The fuel consumption is 3000 L/h. (a) Determine the boiler efficiency. (b) The boiler runs for 20 hours a day and the price of fuel is $0.24/L, what is the annual cost of running the boiler? [94.6%, $5256,000]arrow_forward
- The cooling load of a cold store is 24kW, the evaporator temperature is -10 ° C, the condenser temperature is 40 ° C. R134a is used as the refrigerant. Calculate the mass flow rate, the power consumed by the compressor, the cooling effect coefficient and coefficient according to all these data. (compressor characteristics Heating effect hik (compressor internal efficiency) = 0.75, hmk (mechanical efficiency) = 0.80, hec (electric efficiency) = 0.97 and hkk (belt pulley efficiency) = 0.95) motorarrow_forwardA steam condenser receives 10 kg per second of steam with an enthalpyof 2570 KJ/kg. Steam condenses into liquid and leaves with an enthalpy of160 KJ/kg, if cooling water passes through the condenser with temperatureincreases from 13 o C to 24 o C. Calculate the cooling water flow rate inkg/sec.arrow_forwardA direct contact condenser of the spry type receives 60 kg/s of 925 quality steam at 0.06bar. A dry cooling tower system cools the feedwater to 15 oC. calculate the condensatepump volume flow rate , and the pump power input if the pressure losses in the dry coolingtower system are 2 bar and the pump efficiency is 0.7.arrow_forward
- Can you please help me with question 3arrow_forwardA manufacturer conducted an experiment for an evaporator capacity 500 kW cooling and designed for high COP of 2 when using lithium bromide plus water in an absorption refrigeration system. The evaporator operates 20 C, condenser 40 C & absorber 45 C supplying 1.4 kg/s of water plus lithium bromide solution to the generator. For a condenser size of 650 kW, determine:Ethalphy of the refrigerant entering the Evaporator in kJ/kg Answer in two decimal placesarrow_forwardThe capacity of a refrigeration plant is 60 kW and its design parameters are: -Evaporation temperature: Tev = -40 °C, with DT_evaporator = 8 °C. -Condensing temperature Tcd = 35 °C. -The condenser is cooled by water, which enters at 27°C and leaves at 30°C. The subcooling ∆T it is 5°C. The refrigerant used is R717. - The ∆T of superheating is 5 °C at the outlet of the evaporator and 15 °C in the pipe of aspiration. The pressure loss in the suction pipe is 1°C while the loss of pressure in the pipe on the evaporation coil is 6°C. It is requested: a) Show the scheme of principle suitable for the indicated conditions and draw t he cycle diagram. B) Calculate the theoretical power of the compressor in kW C) Determine the COP and the efficiency of the system.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY