A pump with D = 500 mm delivers Q = 0.725 m3/s of water at H = 10 m at its best efficiency point. If the specific speed of the pump is 1.74, and the required input power is 90 kW, determine the shutoff head, H0, and best efficiency, η. What type of pump is this? If the pump is now run at 900 rpm, by scaling the performance curve, estimate the new flow rate, head, shutoff head, and required power.
Want to see the full answer?
Check out a sample textbook solutionChapter 10 Solutions
Fox and McDonald's Introduction to Fluid Mechanics
Additional Engineering Textbook Solutions
Engineering Mechanics: Dynamics (14th Edition)
Heating Ventilating and Air Conditioning: Analysis and Design
Introduction To Finite Element Analysis And Design
INTERNATIONAL EDITION---Engineering Mechanics: Statics, 14th edition (SI unit)
Statics and Mechanics of Materials (5th Edition)
Introduction to Heat Transfer
- The Head -flowrate curve for a centrifugal pump is given by: HP = 28 -30Q2 Where, HP is in meter and Q is in m3/s . This pump is used to pump water for a system with the following (H-Q) curve: HS = 8 + 150Q2 Where, HS is in meter and Q is in m3/s . What is the resulting flow rate in the system if three pumps are used in series? (a) 0.56 m^3/s (b) 0.48 m^3/s (c) 0.33 m^3/s (d) 0.36 m^3/s HINT: what is the resulting Flow-rate in the system if three pumps are used in series ? Choose correct option abovearrow_forwardA centrifugal pump discharging 10 lps against 25 m of head and operating with an efficiency of 60% requires 4.1 kW at 1000 rpm. What is the theoretical discharge if the speed is increased to 1500 rpm assuming the efficiency remains constant? What is the theoretical head and kW at 1500 rpm?.arrow_forwardThe characteristics of a particular pump are shown in the image below. Calculate the head and discharge one would get at maximum efficiency if the size was doubled and the speed was halved.arrow_forward
- Show the complete solution for this problemarrow_forwardIf a pump with a displacement of 16 cm/rev has an assumed overall efficiency of 90%, what speed and input brake horsepower would be required to deliver 40 1/min at a pressure of 20 MPa?arrow_forwardProblem 1(5): A centrifugal pump transports water between two reservoirs. The pump has an outer diameter of 15 cm, an inner diameter of 8 cm, and a blade width of 2 cm and operates at 1750 rpm. If the water enters the pump axially at ẞ₁ = 45º¸ compute the volume flow rate, Problem 2(10): In the pump of problem 1, the water exits at B₂ 65° when the pump is driven at 1750 rpm. = Compute the minimum power required by the pump?arrow_forward
- A centrifugal pump delivers 227 m³/hr of water from a source 4 meters below the pump centre line to a pressure tank whose pressure is 2.8 kg/cm² . Friction loss estimates are 2 meters in the suction line and 1 metre in the discharge line. The diameter of the suction pipe is 250 mm and the discharge pipe is 200 mm. Find: a. The water horsepower b. The kW rating of the driving motor if the pump efficiency is 70%arrow_forwardA centrifugal pump pumps water at a flow rate of 7 m³/s to a height of 10 m. If the pump works at the best efficiency point, find the pump impeller diameter, pump speed, the best efficiency value of the pump, the head at the best efficiency value, and the specific speed of the pump, given that CQ=0.15 CH=6 CP=0.75.arrow_forwardConsider the following data relating toperformance of a centrifugal pump:speed 1200 rpm, flow rate 30 L/s, head 20 m, and power 5 kW. If the speed of the pump is increased to 1500 rpm, assuming the efficiency isunaltered, Find the new flow rate and head.arrow_forward
- A centrifugal pump supplies water at the rate of 750 liter/s against manometric head of 15 m of water. Pump running at 800rpm. Losses in impeller and casing of the pump is given by 0.03V₂2 where V₂ is absolute water velocity at impeller out. Manometric efficiency of the pump is 85%. If the flow velocity is constant at 3 m/s and assumed zero whirl at inlet, determine a) Blade angle at outlet b) Impeller diameter at outlet c) Impeller width at outlet if blade thickness is negligible The pump input power if overall efficiency is 75%. d)arrow_forwardA centrifugal pump at peak efficiency operates at 700RPM and provides 30ft head for a flow rate of 100gpm. What will be the flow rate and head at peak efficiency if the pump speed is increased to 2500RPM?arrow_forwardA centrifugal pump is driven by a motor. The performance of the pump reveals the folowing information: Power input to the pump by the motor (kW): 0.5, 0.7, 0.9, 1.0, 1.2 Power input to the fluid by the pump (kW): 0.3, 0.55, 0.7, 0.9, 1.0 Plot the efficiency curve. The efficiency of a pump is a function of the flow rate. Assume that the flow-readings corresponding to to power data points are equally spaced.arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY