EBK EXPERIMENTAL ORGANIC CHEMISTRY: A M
6th Edition
ISBN: 9781305687875
Author: Gilbert
Publisher: CENGAGE LEARNING - CONSIGNMENT
expand_more
expand_more
format_list_bulleted
Question
Chapter 6.3, Problem 4E
Interpretation Introduction
Interpretation:The solvent which has more eluting power should be identified from petroleum ether and dichloromethane in normal-phase column chromatography and the way should be identified for eluting the power of a solvent related to its polarity.
Concept introduction:Column chromatography is a large scale solid-liquid adsorption chromatographic technique that can separate mixtures of multiple grams. This is a preparative version of thin layer chromatography that permits separation and isolation of products by the collection of eluted fractions.
Eluting power of a particular substance is referred to as the relative ability of different solvents to move through a given substance down a column.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
True or False: Liquid-solid phase column chromatography is used to separate large up to multigram amounts of mixtures, based on their differences (however small) in polarity.
A solvent passes through a chromatography column in 3.87 min, but the solute requires 7.60 min.
What is the retention factor, k?
k =
What fraction of the time does the solute spend in the mobile phase in the column?
t fraction in mobile phase =
The volume of the stationary phase is 0.133 times the volume of the mobile phase in the column (Vs = 0.133VM).
What is the distribution constant, Kp, for this system?
KD =
%3D
Chromatography involves the separation of two or more compounds/ions caused by their molecular interactions with two phases. True False
Chapter 6 Solutions
EBK EXPERIMENTAL ORGANIC CHEMISTRY: A M
Ch. 6.2 - Prob. 1ECh. 6.2 - Prob. 2ECh. 6.2 - Prob. 3ECh. 6.2 - Prob. 4ECh. 6.2 - Prob. 5ECh. 6.2 - Prob. 6ECh. 6.2 - Prob. 7ECh. 6.2 - Prob. 8ECh. 6.2 - Prob. 9ECh. 6.3 - Prob. 1E
Ch. 6.3 - Prob. 2ECh. 6.3 - Prob. 3ECh. 6.3 - Prob. 4ECh. 6.3 - Prob. 5ECh. 6.3 - Prob. 6ECh. 6.3 - Prob. 7ECh. 6.3 - Prob. 8ECh. 6.3 - Prob. 9ECh. 6.3 - Prob. 10ECh. 6.3 - Prob. 11ECh. 6.3 - Prob. 12ECh. 6.3 - Prob. 13ECh. 6.3 - Prob. 14ECh. 6.3 - Prob. 15ECh. 6.3 - Prob. 16ECh. 6.3 - Prob. 17ECh. 6.3 - Prob. 18ECh. 6.3 - Prob. 19ECh. 6.3 - Prob. 20ECh. 6.4 - Prob. 1ECh. 6.4 - Prob. 2ECh. 6.4 - Prob. 3ECh. 6.4 - Prob. 4ECh. 6.4 - Prob. 5E
Knowledge Booster
Similar questions
- Which statements are true for molecular exclusion chromatography?I Molecular exclusion chromatography separates on the basis of size.II Small molecules that freely pass through the stationary phase, Kav = 0.III Small molecules can fit in the pores of the stationary phase and effectively pass through a larger volume, and elute last.IV The pores in the stationary phase are too small for large molecules to pass through, so large molecules elute last.V Molecular exclusion chromatography with a hydrophilic stationary phase and an aqueous solvent is called gel permeation chromatography. A. II and V B. I, II, and IV C. III, IV, and V D. No correct combinations given above E. I, III, and IV F. I, II, III, and Varrow_forwardA young researcher set out to develop a method for quantifying the polycyclic aromatic hydrocarbon (PAH) content in a contaminated soil sample using open tubular gas chromatography. During the initial stages of method development, the researcher was unable to separate the early eluting compounds, anthracene and naphthalene, with baseline resolution. Select the possible modifications the researcher could make to improve the resolution. use a column with a smaller inner diameter decrease the column length increase the stationary phase thickness increase the temperature choose a different stationary phasearrow_forwardDifferentiate normal phase chromatography from reverse phase chromatography. From which of the two governs the video demonstration in TLC and paper chromatography? How do you say so?arrow_forward
- Waooo hiiiiiarrow_forward4.Consider the peaks for pentafluorobenzene and benzene in the gas chromatogram shown here. The elution time for unretained solute is 1.06 min. The open tubular column is 30.0 m in length and 0.530 mm in diameter, with a layer of stationary phase 3.0 μm thick on the inner wall. a) Measruing the width, w, at the baseline on the chromatogram, find the number of plates for these two compounds b) Use your answer to (a) to find the resolution between the two peaks c) Using the number of plates N=sqrtN1*N2 with the values from (a) calcuate what the resolution should be and compare your answer with the measured resolution in barrow_forwardOne method for the quantitative determination of the concentration of constituents in a sample analyzed by gas chromatography is area normalization. Here, complete elution of all the sample constituents is necessary. The area of each peak is then measured and corrected for differences in detector response to the different eluates. This correction involves dividing the area by an empirically determined correction factor. The concentration of the analyte is found from the ratio of its corrected area to the total corrected area of all peaks. For a chromatogram containing three peaks, the relative areas were found to be 16.4, 45.2 and 30.2, in order of increasing retention time. Calculate the percentage of each compound if the relative detector responses were 0.60, 0.78 and 0.88, respectively.arrow_forward
- Explain how the separation of various components of a mixture isachieved in column chromatography.arrow_forwardA student researcher performed a chromatographic separation of caffeine and aspartame. The retention time for caffeine, tc, was found to be 209.6 s with a baseline peak width, w., of 14.4 s. The retention time for aspartame, ta, was 260.0 s with a baseline peak width, wa, of 21.2 s. The retention time for the unretained solvent methanol was 49.2 s. Calculate the average plate height, H, in micrometers for this separation, given that it was performed on a 22.1 cm long column. H = um %3D Calculate the resolution, R, for this separation using the widths of the peaks. R = Calculate the resolution if the number of theoretical plates were to increase by a factor of 2. R2N =arrow_forwardWhich of the following are characteristics of normal-phase chromatography? I - The stationary phase is polar. II - The mobile phase is more polar than the stationary phase. III - The eluent strength increases as the mobile phase becomes less polar. IV - The eluent strength increases as the mobile phase becomes more polar. V - the stationary phase is nonpolar. Answers to choose from: I and IV I, IV and V I and III II and IV II and V ...and why?arrow_forward
- 1a) Hexane, CH3(CH2)4CH3, is found to have a long retention time when separated from a mixture. A column with a C18 (18-carbon chain) stationary phase and a methanol-water modal phase is used for the separation. Explain why hexane has a long retention time. 1b)You wish to chromatographically seperate a mixtureof the follwing compunds. Which of the two compounds will be most difficult to seperatate from one another? Why?arrow_forwardGiven below is a diagram of separation of two components of a mixture in a reverse phase chromatographic column. From the diagram, which component is the most non-polar?arrow_forwardCan paper chromatography be used to separate and identify very volatile substances? How do I prove this.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK A SMALL SCALE APPROACH TO ORGANIC LChemistryISBN:9781305446021Author:LampmanPublisher:CENGAGE LEARNING - CONSIGNMENTMacroscale and Microscale Organic ExperimentsChemistryISBN:9781305577190Author:Kenneth L. Williamson, Katherine M. MastersPublisher:Brooks ColePrinciples of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:9781305446021
Author:Lampman
Publisher:CENGAGE LEARNING - CONSIGNMENT
Macroscale and Microscale Organic Experiments
Chemistry
ISBN:9781305577190
Author:Kenneth L. Williamson, Katherine M. Masters
Publisher:Brooks Cole
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning