A two-evaporator compression refrigeration system as shown in Fig. P11–62 uses refrigerant-134a as the working fluid. The system operates evaporator 1 at 0°C, evaporator 2 at −26.4°C, and the condenser at 800 kPa. The refrigerant is circulated through the compressor at a rate of 0.1 kg/s, and the low-temperature evaporator serves a cooling load of 8 kW. Determine the cooling rate of the high-temperature evaporator, the power required by the compressor, and the COP of the system. The refrigerant is saturated liquid at the exit of the condenser and saturated vapor at the exit of each evaporator, and the compressor is isentropic.
FIGURE P11–62
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
An ideal vapor-compression refrigeration cycle using refrigerant-134a as the working fluid is used to cool a brine solution to
-5°C. This solution is pumped to various buildings for the purpose of air-conditioning. The refrigerant evaporates at -18°C with a
total mass flow rate of 5 kg/s and condenses at 600 kPa. Determine the COP of the cycle and the total cooling load. (Take the
required values from saturated refrigerant-134a tables.)
The COP of the cycle is
, and the total cooling load is
kW.
A two-evaporator compression refrigeration system as shown in the figure uses refrigerant-134a as the working fluid. The system
operates evaporator 1 at 0°C, evaporator 2 at -26.4°C, and the condenser at 800 kPa. The refrigerant is circulated through the
compressor at a rate of 0.1 kg/s, and the low-temperature evaporator serves a cooling load of 8 kW. Determine the cooling rate of the
high-temperature evaporator, the power required by the compressor, and the COP of the system. The refrigerant is a saturated liquid
at the exit of the condenser and a saturated vapor at the exit of each evaporator, and the compressor is isentropic. The pressure
reducing valve drops the pressure of the evaporator 1 discharge to evaporator 2 discharge pressure.
(Take the required values from saturated refrigerant-134a tables.)
1
↑
7
Pressure
reducing
valve
m₁ + m₂
Condenser
m₁
Evaporator 1
Evaporator 2
m₂
S
The cooling rate of the high-temperature evaporator is
of the system is
3
kW, the power required by…
2. A cascade refrigeration
system using R - 22 in the low
- temperature circuit and
ammonia (R-717) in the high
- temperature circuit has a
load of 150 kW. The low -
temperature circuit operates
at an evaporating
temperature of -50°C and a
condensing pressure of 500
kPa. Refrigerant leaves the
low temperature evaporator
as saturated vapor and enters
the suction of the low -
temperature compressor at -
45°C. Liquid refrigerant exits
the condenser at 02°C. The
high temperature circuit
-
operates at an evaporating
temperature of -10°C and a
condensing pressure of 1200
kPa. The refrigerant exits both
evaporator and condenser at
saturated conditions.
Calculate the power input to
the high temperature circuit
-
compressor, kW.
Chapter 11 Solutions
THERMODYNAMICS (LL)-W/ACCESS >CUSTOM<
Ch. 11.10 - Why do we study the reversed Carnot cycle even...Ch. 11.10 - Why is the reversed Carnot cycle executed within...Ch. 11.10 - A steady-flow Carnot refrigeration cycle uses...Ch. 11.10 - Refrigerant-134a enters the condenser of a...Ch. 11.10 - Does the ideal vapor-compression refrigeration...Ch. 11.10 - Why is the throttling valve not replaced by an...Ch. 11.10 - In a refrigeration system, would you recommend...Ch. 11.10 - Does the area enclosed by the cycle on a T-s...Ch. 11.10 - Consider two vapor-compression refrigeration...Ch. 11.10 - It is proposed to use water instead of...
Ch. 11.10 - The COP of vapor-compression refrigeration cycles...Ch. 11.10 - A 10-kW cooling load is to be served by operating...Ch. 11.10 - An ice-making machine operates on the ideal...Ch. 11.10 - An air conditioner using refrigerant-134a as the...Ch. 11.10 - An ideal vapor-compression refrigeration cycle...Ch. 11.10 - A refrigerator operates on the ideal...Ch. 11.10 - A refrigerator uses refrigerant-134a as the...Ch. 11.10 - An ideal vapor-compression refrigeration cycle...Ch. 11.10 - A refrigerator uses refrigerant-134a as its...Ch. 11.10 - A refrigerator uses refrigerant-134a as the...Ch. 11.10 - A commercial refrigerator with refrigerant-134a as...Ch. 11.10 - The manufacturer of an air conditioner claims a...Ch. 11.10 - Prob. 24PCh. 11.10 - How is the second-law efficiency of a refrigerator...Ch. 11.10 - Prob. 26PCh. 11.10 - Prob. 27PCh. 11.10 - Prob. 28PCh. 11.10 - Bananas are to be cooled from 28C to 12C at a rate...Ch. 11.10 - A vapor-compression refrigeration system absorbs...Ch. 11.10 - A room is kept at 5C by a vapor-compression...Ch. 11.10 - Prob. 32PCh. 11.10 - A refrigerator operating on the vapor-compression...Ch. 11.10 - When selecting a refrigerant for a certain...Ch. 11.10 - A refrigerant-134a refrigerator is to maintain the...Ch. 11.10 - Consider a refrigeration system using...Ch. 11.10 - A refrigerator that operates on the ideal...Ch. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - Do you think a heat pump system will be more...Ch. 11.10 - What is a water-source heat pump? How does the COP...Ch. 11.10 - A heat pump operates on the ideal...Ch. 11.10 - Refrigerant-134a enters the condenser of a...Ch. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - The liquid leaving the condenser of a 100,000...Ch. 11.10 - Reconsider Prob. 1144E. What is the effect on the...Ch. 11.10 - A heat pump using refrigerant-134a heats a house...Ch. 11.10 - A heat pump using refrigerant-134a as a...Ch. 11.10 - Reconsider Prob. 1148. What is the effect on the...Ch. 11.10 - Prob. 50PCh. 11.10 - How does the COP of a cascade refrigeration system...Ch. 11.10 - Consider a two-stage cascade refrigeration cycle...Ch. 11.10 - Can a vapor-compression refrigeration system with...Ch. 11.10 - Prob. 54PCh. 11.10 - A certain application requires maintaining the...Ch. 11.10 - Prob. 56PCh. 11.10 - Repeat Prob. 1156 for a flash chamber pressure of...Ch. 11.10 - Prob. 59PCh. 11.10 - A two-stage compression refrigeration system with...Ch. 11.10 - A two-stage compression refrigeration system with...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - Repeat Prob. 1163E if the 30 psia evaporator is to...Ch. 11.10 - Consider a two-stage cascade refrigeration cycle...Ch. 11.10 - How does the ideal gas refrigeration cycle differ...Ch. 11.10 - Prob. 67PCh. 11.10 - Devise a refrigeration cycle that works on the...Ch. 11.10 - How is the ideal gas refrigeration cycle modified...Ch. 11.10 - Prob. 70PCh. 11.10 - How do we achieve very low temperatures with gas...Ch. 11.10 - An ideal gas refrigeration system operates with...Ch. 11.10 - Air enters the compressor of an ideal gas...Ch. 11.10 - Repeat Prob. 1173 for a compressor isentropic...Ch. 11.10 - An ideal gas refrigeration cycle uses air as the...Ch. 11.10 - Rework Prob. 1176E when the compressor isentropic...Ch. 11.10 - A gas refrigeration cycle with a pressure ratio of...Ch. 11.10 - A gas refrigeration system using air as the...Ch. 11.10 - An ideal gas refrigeration system with two stages...Ch. 11.10 - Prob. 81PCh. 11.10 - Prob. 82PCh. 11.10 - What are the advantages and disadvantages of...Ch. 11.10 - Prob. 84PCh. 11.10 - Prob. 85PCh. 11.10 - Prob. 86PCh. 11.10 - Prob. 87PCh. 11.10 - Heat is supplied to an absorption refrigeration...Ch. 11.10 - An absorption refrigeration system that receives...Ch. 11.10 - An absorption refrigeration system receives heat...Ch. 11.10 - Heat is supplied to an absorption refrigeration...Ch. 11.10 - Prob. 92PCh. 11.10 - Prob. 93PCh. 11.10 - Consider a circular copper wire formed by...Ch. 11.10 - An iron wire and a constantan wire are formed into...Ch. 11.10 - Prob. 96PCh. 11.10 - Prob. 97PCh. 11.10 - Prob. 98PCh. 11.10 - Prob. 99PCh. 11.10 - Prob. 100PCh. 11.10 - Prob. 101PCh. 11.10 - Prob. 102PCh. 11.10 - A thermoelectric cooler has a COP of 0.18, and the...Ch. 11.10 - Prob. 104PCh. 11.10 - Prob. 105PCh. 11.10 - Prob. 106PCh. 11.10 - Rooms with floor areas of up to 15 m2 are cooled...Ch. 11.10 - Consider a steady-flow Carnot refrigeration cycle...Ch. 11.10 - Consider an ice-producing plant that operates on...Ch. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - A heat pump operates on the ideal...Ch. 11.10 - A large refrigeration plant is to be maintained at...Ch. 11.10 - Repeat Prob. 11112 assuming the compressor has an...Ch. 11.10 - An air conditioner with refrigerant-134a as the...Ch. 11.10 - A refrigerator using refrigerant-134a as the...Ch. 11.10 - Prob. 117RPCh. 11.10 - An air conditioner operates on the...Ch. 11.10 - Consider a two-stage compression refrigeration...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - The refrigeration system of Fig. P11122 is another...Ch. 11.10 - Repeat Prob. 11122 if the heat exchanger provides...Ch. 11.10 - An aircraft on the ground is to be cooled by a gas...Ch. 11.10 - Consider a regenerative gas refrigeration cycle...Ch. 11.10 - An ideal gas refrigeration system with three...Ch. 11.10 - Prob. 130RPCh. 11.10 - Derive a relation for the COP of the two-stage...Ch. 11.10 - Prob. 133FEPCh. 11.10 - Prob. 134FEPCh. 11.10 - Prob. 135FEPCh. 11.10 - Prob. 136FEPCh. 11.10 - Prob. 137FEPCh. 11.10 - An ideal vapor-compression refrigeration cycle...Ch. 11.10 - Prob. 139FEPCh. 11.10 - An ideal gas refrigeration cycle using air as the...Ch. 11.10 - Prob. 141FEPCh. 11.10 - Prob. 142FEP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- When a standard-efficiency air-cooled condenser is used, the condensing refrigerant will normally be higher in temperature than the entering air temperature.arrow_forwardCondensers in these refrigerators are all_______cooled.arrow_forwardWhat are the approximate temperature ranges tor low-, medium-, and high-temperature refrigeration applications?arrow_forward
- An ideal vapor-compression refrigeration cycle using refrigerant-134a as the working fluid is used to cool a brine solution to -5°C. This solution is pumped to various buildings for the purpose of air-conditioning. The refrigerant evaporates at -12.00°C with a total mass flow rate of 8.000 kg/s and condenses at 600 kPa. Determine the COP of the cycle and the total cooling load. (Take the required values from saturated refrigerant-134a tables.) The COP of the cycle is (Round the final answer to three decimal places.) and the total cooling load is kW.arrow_forwardA two-stage compression refrigeration system operates with refrigerant-134a between the pressure limits of 1.4 MPa and 0.10 MPa. The refrigerant leaves the condenser as a saturated liquid and is throttled to a flash chamber operating at 0.6 MPa. he flash chamber is maintained at the same pressure as the low pressure discharge which is 0.6 Mpa. The vapor in the flash chamber is then compressed to the condenser pressure by the high-pressure compressor, and the liquid is throttled to the evaporator pressure. Assume the refrigerant leaves the evaporator as saturated vapor and both compressors are isentropic. Consider a mass flow rate of 0.19 kg/s through the condenser. (Take the required values from saturated refrigerant-134a tables.) Determine the fraction of the refrigerant that evaporates as it is throttled to the flash chamber. (You must provide an answer before moving to the next part.) The fraction of the refrigerant that evaporates as it is throttled to the flash chamber is…arrow_forwardA two-stage compression refrigeration system operates with refrigerant-134a between the pressure limits of 1.4 MPa and 0.10 MPa. The refrigerant leaves the condenser as a saturated liquid and is throttled to a flash chamber operating at 0.6 MPa. he flash chamber is maintained at the same pressure as the low pressure discharge which is 0.6 Mpa. The vapor in the flash chamber is then compressed to the condenser pressure by the high-pressure compressor, and the liquid is throttled to the evaporator pressure. Assume the refrigerant leaves the evaporator as saturated vapor and both compressors are isentropic. Consider a mass flow rate of 0.19 kg/s through the condenser. (Take the required values from saturated refrigerant-134a tables.) Determine the coefficient of performance. The coefficient of performance is ______.arrow_forward
- Determine the degrees of subcooling at the exit of the condenser of a 2-ton air-conditioner system. The system operates on the ideal, vapor-compression refrigerationcycle with the following design parameters: R-134a flow rate 0.05 kg/s Evaporator Pressure 200 kPa Condenser Pressure 1200 kPaarrow_forwardA food storage locker requires a refrigeration system of 2,400 kJ/min capacity at an evaporator temperature of -10OC and a condenser temperature of 30OC. The refrigerant used is freon-12 and sub-cooled by 6OC before entering the expansion valve and vapor is superheated by 7OC before leaving the evaporator coil. The compression of refrigerant is isentropic. The refrigeration compressor is two-cylinder, single-acting with stroke equal to 1.25 times the bore diameter and operates at 1000 rpm. Determine: (a) refrigerating effect, (b) mass of refrigerant to be circulated, (c) theoretical piston displacement per minute, (d) theoretical power to run the compressor in kW, (e) heat removed from the condenser per min. (f) theoretical bore and stroke of compressor.arrow_forward* 1. A cascade refrigeration system using R - 22 in the low - temperature circuit and ammonia (R - 717) in the high - temperature circuit has a load of 150 kW. The low - temperature circuit operates at an evaporating temperature of -50°C and a condensing pressure of 500 kPa. Refrigerant leaves the low temperature evaporator as saturated vapor and enters the suction of the low - mperature compressor at - 45°C. Liquid refrigerant exits the condenser at 02°C. The high temperature circuit operates at an evaporating temperature of -10°C and a condensing pressure of 1200 kPa. The refrigerant exits both evaporator and condenser at saturated conditions. Calculate the power input to the low-temperature circuit compressor, kW.arrow_forward
- A single-effect falling-film evaporator is used to concentrate orange juice from 14% to 45% solids. The evaporator utilizes a mechanical refrigeration cycle using ammonia as a refrigerant for heating and for condensing the vapors. The refrige-ration cycle is operated at a high-side pressure of 200 psia (1.379 MPa) and a low-side pressure of 50 psia (344.7 kPa). The evaporator is operated at a vapor temperature of 90oF (32.2oC). Feed enters at 70oF (21.1oC). The ratio of insoluble to soluble solids in the juice is 0.09, and the soluble solids consist of glucose and sucrose in 70:30 ratio. Consider the ΔT as the log mean ΔT between the liquid refrigerant temperature and the feed temperature at one point and the hot refri-gerant gas temperature and the concentrated liquid boiling temperature at the other point. The evaporator has a heat transfer surface area of 100 ft2 (9.29 m2), and an overall heat transfer coefficient of 300 BTU (h.ft2.oF) or 1073 W/(m2.K) may be expected. Calculate:…arrow_forwardA two-evaporator, multiple EV,and single compression refrigeration system uses refrigerant-134a as the working fluid. The system operates evaporator 1 at 0°C, evaporator 2 at -26.4°C, and the condenser at 800kPa. The refrigerant is circulated through the compressor at a rate of 0.1kg/s and the low temperature evaporator serves a cooling load of 8 kW.Determine the cooling rate of the high-temperature evaporator, the power required by the compressor, and the COP of the system. The refrigerant is saturated liquid at the exit of the condenser and saturated vapor at the exit of each evaporator, and the compressor is isentropic.arrow_forwardA two-evaporator, multiple EV,and multiple compression refrigeration system uses refrigerant-134a as the working fluid. The system operates evaporator 1 at 0°C, evaporator 2 at -26.4°C, and the condenser at 800kPa. The refrigerant is circulated through the compressor at a rate of 0.1kg/s and the low temperature evaporator serves a cooling load of 8 kW.Determine the cooling rate of the high-temperature evaporator, the power required by the compressor, and the COP of the system. The refrigerant is saturated liquid at the exit of the condenser and saturated vapor at the exit of each evaporator, and the compressor is isentropic.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY