Two lossless transmission lines having different characteristic impedances are to be joined end to end. The impedances are
Want to see the full answer?
Check out a sample textbook solutionChapter 10 Solutions
Engineering Electromagnetics
- In the Transmission Line Simulator, the Transmission Line is composed of which parameter/s? O A. The Shunt Conductance Only O B. The Series Impedance and Shunt Capacitance O C. The Shunt Capacitance Only O D. The Series Impedance Onlyarrow_forwardIs it possible to measure the phase-shift angle in an AC single-phase circuit by an indirect method using an ammeter and a voltmeter? - Yes, but an instrument must be added to measure the active resistance of the load. - Yes, but an instrument must be added to measure the active power dissipated by the load. - Yes, but an instrument must be added to measure the frequency.arrow_forwardA single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight 1-The capacitance in uF/km without effect of ground is 2-The capacitance in pF/km with effect of ground isarrow_forward
- In the figure, bus 1 is the reference bus, V1 = 1.06 p.u and the angle is 0.. A load with active power= 100 MW and reactive power = 50 Mvar is connected to bus 2. The line impedance is z12 = 0.12 + j0.16 p.u on a base of 100 MVA. Start with an initial estimate of |V2|0) = 1.0 p.u and 820) = 0•. Find |V2| () (one iteration). 100 MW 212 = 0.12 + j0.16 ++ 50 Mvar Vị = 1.0/0° О а. |V2| (1) = 0.4 p.u. Ob. |V2| (1) = 0.5 p.u. Oc. |V2| (1) = 0.7 p.u. d. (1) = 0.8 p.u. е. |V2| (1) = 0.6 p.u.arrow_forwardD6arrow_forwardi need the answer quicklyarrow_forward
- The instantaneous power absorbed by the load in a single-phase ac circuit, for a general R LC load under sinusoidal-steady-state excitation. is (a) Nonzero constant (b) Zero (c) Containing double-frequency componentsarrow_forwardThe affect of the earth plane is to slightly increase the capacitance, and as the line height increases, the effect of earth becomes negligible. True Falsearrow_forwardSubject Is power transmission lines and Distrubtionarrow_forward
- C and D and the plagiarism should be zeroarrow_forwardA single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight meter. Determine 1)The capacitance in uF/km without effect of ground 2)The capacitance in uF/km with effect of groundarrow_forward10arrow_forward