A combined gas–steam power cycle uses a simple gas turbine for the topping cycle and simple Rankine cycle for the bottoming cycle. Atmospheric air enters the gas turbine at 101 kPa and 20°C, and the maximum gas cycle temperature is 1100°C. The compressor pressure ratio is 8; the compressor isentropic efficiency is 85 percent; and the gas turbine isentropic efficiency is 90 percent. The gas stream leaves the heat exchanger at the saturation temperature of the steam flowing through the heat exchanger. Steam flows through the heat exchanger with a pressure of 6000 kPa and leaves at 320°C. The steam-cycle condenser operates at 20 kPa, and the isentropic efficiency of the steam turbine is 90 percent. Determine the mass flow rate of air through the air compressor required for this system to produce 100 MW of power. Use constant specific heats for air at room temperature.
Want to see the full answer?
Check out a sample textbook solutionChapter 10 Solutions
THERMODYNAMICS (LL)-W/ACCESS >CUSTOM<
Additional Engineering Textbook Solutions
Heating Ventilating and Air Conditioning: Analysis and Design
Applied Statics and Strength of Materials (6th Edition)
Fundamentals of Heat and Mass Transfer
Vector Mechanics for Engineers: Statics, 11th Edition
Fundamentals Of Thermodynamics
Vector Mechanics for Engineers: Statics and Dynamics
- An ideal reheat Rankine cycle with water as the working fluid operates the inlet of the high-pressure turbine at 7000 kPa and 450°C, the inlet of the low-pressure turbine at 500 kPa and 500°C, and the condenser at 10 kPa. Determine the mass flow rate through the boiler needed for this system to produce a net 5000 kW of power and the thermal efficiency of the cycle. Use steam tables. kg/s. The mass flow rate through the boiler needed for this system to produce a net 5000 kW of power is The thermal efficiency is %.arrow_forwardConsider an ideal reheat-regenerative Rankine cycle whose boiler pressure is at 15 MPaa and a condenser pressure of 10 kPaa. Steam enters the turbine at 550 °C. The first of the two extractions of steam occurs at 6 MPaa and the remainder is reheated until the temperature becomes 500 °C. The second extraction occurs at 1 MPaa and again, the remaining steam is reheated up to 480 °C. If the mass flow rate of the throttled steam is 30 kg/s, determine: the hourly quantities of steam extracted= kg/hr and kg/hr the amount of heat added = BTU/hr the amount of heat rejected = BTU/hr the net work of the cycle = BTU/hr the thermal efficiency of the cycle = %arrow_forwardPlease answer step by steparrow_forward
- Please answer step by steparrow_forwardHeat recovery steam generator joint between gas and steam turbine in combined cycle power plant. Air enters the compressor at 300 K and compressor pressure ratio is 11, turbine inlet temperature is1100 K. The combustion gases leaving the gas turbine are used to heat the steam at 5 MPa to 350°C in a heat recovery steam generator (HRSG). The combustion gases leave the HRSG at 420 K. An open feedwater heater incorporated with the steam cycle operates at a pressure of 0.8 MPa. The condenser pressure is 10 kPa. Assuming isentropic efficiencies of 100 percent for the pump, 82 percent for the compressor, and 86 percent for the gas and steam turbines, the combined gas-steam power plant that has a net power output of 280 MW determine (a) the mass flow rate ratio of air to steam, (b) the required rate of heat input in the combustion chamber, and (c) the thermal efficiency of the combined cycle.arrow_forwardThe net work output and the thermal efficiency for the Carnot and the simple ideal Rankine cycles with steam as the working fluid are to be calculated and compared. Steam enters the turbine in both cases at 5 MPa as a saturated vapor, and the condenser pressure is 50 kPa. In the Rankine cycle, the condenser exit state is saturated liquid and in the Carnot cycle, the boiler inlet state is saturated liquid. Draw the T-s diagrams for both cycles.arrow_forward
- A simple Rankine cycle uses water as the working fluid. The boiler operates at 6000 kPa and the condenser at 50 kPa. At the entrance to the turbine, the temperature is 450°C. The isentropic efficiency of the turbine is 94 percent, pressure and pump losses are negligible, and the water leaving the condenser is subcooled by 6.3°C. The boiler is sized for a mass flow rate of 19 kg/s. Determine the rate at which heat is added in the boiler, the power required to operate the pumps, the net power produced by the cycle, and the thermal efficiency. Use steam tables. The rate at which heat is added in the boiler is 4192.12 kW. The power required to operate the pumps is 59354.47 kW. The net power produced by the cycle is -55162.35 ✪ kW. The thermal efficiency of the cycle is 13.16 %.arrow_forwardExample: Consider the combined gas-steam power cycle. The topping cycle is a gas-turbine cycle that has a pressure ratio of 8. Air enters the compressor at 300 K and the turbine at 1300 K. The isentropic efficiency of the compressor is 80 percent, and that of the gas turbine is 85 percent. The bottoming cycle is a simple ideal Rankine cycle operating between the pressure limits of 7 MPa and 5 kPa. Steam is heated in a heat exchanger by the exhaust gases to a temperature of 500°C. The exhaust gases leave the heat exchanger at 450 K. Lec. (7) T, KA Determine (a) the ratio of the mass flow rates of the steam and the combustion gases and (b) the thermal efficiency of the combined cycle. 1300 450 300 5' 7 MPa Power Plant 5 kPa 500°C 7 MPa Dr. Omar M. Ali 4arrow_forwardThermal engineeringarrow_forward
- Refrigerant-134a is used as the working fluid in a simple ideal Rankine cycle which operates the boiler at 2000 kPa and the condenser at 24C. The mixture at the exit of the turbine has a quality of 93 percent. Determine the turbine inlet temperature, the cycle thermal efficiency, and the back-work ratio of this cycle.arrow_forwardNo 1 A Rankine cycle using superheat and reheat applications. Steam enters the stage 1 turbine at 8 MPa and a temperature of 480°C and expands at a pressure of 0.7 MPa. The steam is then reheated to a temperature of 440°C before entering the stage 2 turbine, where the steam expands in the condenser at a pressure of 0.008 MPa. The net power generated is 100 MW. No2 Using the data in number 1 above plus other data, namely each turbine has the same isentrapic efficiency of 85%, calculate the thermal efficiency of the cycle P.s Answer the number 2, number 1 just reference to answer number 2,thxarrow_forwardParvinbhaiarrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY