Consider the radial power system shown below. Assume that the generator is ideal, with a terminal voltage of 1.0 pu. The system data are given in the accompanying table. If the line-to-ground fault currents flowing in circuit breaker B2 for faults at buses 2 and 3 are respectively 12.55A and 6.34A, then the corresponding faulted phase voltages in pu are equal to: 2 3 5 From To Positive sequence Zero sequence impedance impedance B₁ B₂ B₂ B 1 2 0.01 + j0.05 0.02+0.13 2 3 0.003+j0.04 0.01+j0.16 3 4 0.008+j0.04 0.04+j0.15 5 0.01 +j0.05 0.03+j0.15 Select one: a. OV, 0.31V O b. 0V, 0.51V О с. 1V, 0.31V ○ d. 1V, 0.51V
Consider the radial power system shown below. Assume that the generator is ideal, with a terminal voltage of 1.0 pu. The system data are given in the accompanying table. If the line-to-ground fault currents flowing in circuit breaker B2 for faults at buses 2 and 3 are respectively 12.55A and 6.34A, then the corresponding faulted phase voltages in pu are equal to: 2 3 5 From To Positive sequence Zero sequence impedance impedance B₁ B₂ B₂ B 1 2 0.01 + j0.05 0.02+0.13 2 3 0.003+j0.04 0.01+j0.16 3 4 0.008+j0.04 0.04+j0.15 5 0.01 +j0.05 0.03+j0.15 Select one: a. OV, 0.31V O b. 0V, 0.51V О с. 1V, 0.31V ○ d. 1V, 0.51V
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter8: Symmetrical Components
Section: Chapter Questions
Problem 8.34P
Related questions
Question
![Consider the radial power system shown below. Assume that the generator is ideal, with a terminal voltage of 1.0 pu. The system data are
given in the accompanying table. If the line-to-ground fault currents flowing in circuit breaker B2 for faults at buses 2 and 3 are respectively
12.55A and 6.34A, then the corresponding faulted phase voltages in pu are equal to:
2
3
5
From To Positive sequence Zero sequence
impedance
impedance
B₁
B₂
B₂
B
1
2
0.01 + j0.05
0.02+0.13
2
3
0.003+j0.04
0.01+j0.16
3
4
0.008+j0.04
0.04+j0.15
5
0.01 +j0.05
0.03+j0.15
Select one:
a. OV, 0.31V
O b. 0V, 0.51V
О с.
1V, 0.31V
○ d.
1V, 0.51V](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fd99b6acb-3c56-46a2-8aaf-762988209417%2F68d64abd-a390-40c5-ada7-9ad50cda0f33%2Fexngx0f_processed.jpeg&w=3840&q=75)
Transcribed Image Text:Consider the radial power system shown below. Assume that the generator is ideal, with a terminal voltage of 1.0 pu. The system data are
given in the accompanying table. If the line-to-ground fault currents flowing in circuit breaker B2 for faults at buses 2 and 3 are respectively
12.55A and 6.34A, then the corresponding faulted phase voltages in pu are equal to:
2
3
5
From To Positive sequence Zero sequence
impedance
impedance
B₁
B₂
B₂
B
1
2
0.01 + j0.05
0.02+0.13
2
3
0.003+j0.04
0.01+j0.16
3
4
0.008+j0.04
0.04+j0.15
5
0.01 +j0.05
0.03+j0.15
Select one:
a. OV, 0.31V
O b. 0V, 0.51V
О с.
1V, 0.31V
○ d.
1V, 0.51V
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 2 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Recommended textbooks for you
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning