PART 1 - BALANCED AND UNBALANCED THREE-PHASE SYSTEMS Task 1.1 1. Build the Balanced Three-Phase Y-Y system using MATLAB Simulink as shown in figure 1.1 2. Select 230Vrms of each phase (R-Y-B), 50Hz 3. Select the load is R₁ = Rb = Rc = 40 W; La Lb Le = 0.01 H, and C₁ = C₁ = Cc = 100μF; 4. Observe and plot the active and reactive powers and power factor. 5. Increase the L₁ = L₁ = L = 0.1 H, observe the reactive power and power factor, and comment on it. Formula: Power factor P S Continuous Continuous Power Measurement RMS QUE RMS RMS2 A Vabc labc B C ° RMS Figure 1.1 Balanced three-phase circuit with star-connected load. Continuous Power Measurement (Three-Phase) ••

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.13MCQ
icon
Related questions
Question
PART 1 - BALANCED AND UNBALANCED THREE-PHASE SYSTEMS
Task 1.1
1. Build the Balanced Three-Phase Y-Y system using MATLAB Simulink as shown in figure 1.1
2. Select 230Vrms of each phase (R-Y-B), 50Hz
3. Select the load is R₁ = Rb = Rc = 40 W; La Lb Le = 0.01 H, and C₁ = C₁ = Cc = 100μF;
4. Observe and plot the active and reactive powers and power factor.
5. Increase the L₁ = L₁ = L = 0.1 H, observe the reactive power and power factor, and comment on it.
Formula:
Power factor
P
S
Continuous
Continuous
Power
Measurement
RMS
QUE
RMS
RMS2
A
Vabc
labc
B
C
°
RMS
Figure 1.1 Balanced three-phase circuit with star-connected load.
Continuous
Power Measurement
(Three-Phase)
••
Transcribed Image Text:PART 1 - BALANCED AND UNBALANCED THREE-PHASE SYSTEMS Task 1.1 1. Build the Balanced Three-Phase Y-Y system using MATLAB Simulink as shown in figure 1.1 2. Select 230Vrms of each phase (R-Y-B), 50Hz 3. Select the load is R₁ = Rb = Rc = 40 W; La Lb Le = 0.01 H, and C₁ = C₁ = Cc = 100μF; 4. Observe and plot the active and reactive powers and power factor. 5. Increase the L₁ = L₁ = L = 0.1 H, observe the reactive power and power factor, and comment on it. Formula: Power factor P S Continuous Continuous Power Measurement RMS QUE RMS RMS2 A Vabc labc B C ° RMS Figure 1.1 Balanced three-phase circuit with star-connected load. Continuous Power Measurement (Three-Phase) ••
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning