2-15. 2-15. An autotransformer is used to connect a 12.6-kV distribution line to a 13.8-kV dis- tribution line. It must be capable of handling 2000 kVA. There are three phases, con- nected Y-Y with their neutrals solidly grounded. (a) What must the NC/NSE turns ratio be to accomplish this connection? (b) How much apparent power must the windings of each autotransformer handle? (c) What is the power advantage of this autotransformer system? (d) If one of the autotransformers were reconnected as an ordinary transformer, what would its ratings be?

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.56P: Three single-phase two-winding transformers, each rated 3kVA,220/110volts,60Hz, with a 0.10 per-unit...
icon
Related questions
Question

Fundamentals Of Energy Systems HW 6 Q5

2-15.
2-15. An autotransformer is used to connect a 12.6-kV distribution line to a 13.8-kV dis-
tribution line. It must be capable of handling 2000 kVA. There are three phases, con-
nected Y-Y with their neutrals solidly grounded.
(a) What must the NC/NSE turns ratio be to accomplish this connection?
(b) How much apparent power must the windings of each autotransformer handle?
(c) What is the power advantage of this autotransformer system?
(d) If one of the autotransformers were reconnected as an ordinary transformer,
what would its ratings be?
Transcribed Image Text:2-15. 2-15. An autotransformer is used to connect a 12.6-kV distribution line to a 13.8-kV dis- tribution line. It must be capable of handling 2000 kVA. There are three phases, con- nected Y-Y with their neutrals solidly grounded. (a) What must the NC/NSE turns ratio be to accomplish this connection? (b) How much apparent power must the windings of each autotransformer handle? (c) What is the power advantage of this autotransformer system? (d) If one of the autotransformers were reconnected as an ordinary transformer, what would its ratings be?
Expert Solution
steps

Step by step

Solved in 2 steps with 5 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT