Tests are carried on 400 V, 60 Hz, Y-connected, wound rotor three-phase induction motor with the following test results: DC Test: 21 V, 43 A No Load Test: 400 V, 20 A, 1200 W, 60 Hz Blocked Rotor Test: 100 V, 44 A, 2700 W, 19 Hz Find R1, X1, R2, X2, and Xm of this motor? xxx₁ = 0.5xbm fy Pen Pd 51-5 NN (1-5) 1208 1 [10Marks] N wr P

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter32: Three-phase Motors
Section: Chapter Questions
Problem 6RQ: Name three factors that determine the torque produced by an induction motor.
icon
Related questions
Question
Tests are carried on 400 V, 60 Hz, Y-connected, wound rotor three-phase induction motor with
the following test results:
DC Test: 21 V, 43 A
No Load Test: 400 V, 20 A, 1200 W, 60 Hz
Blocked Rotor Test: 100 V, 44 A, 2700 W, 19 Hz
Find R1, X1, R2, X2, and Xm of this motor?
xxx₁ = 0.5xbm fy
Pen Pd
51-5
NN (1-5)
1208
1 [10Marks]
N
wr
P
Transcribed Image Text:Tests are carried on 400 V, 60 Hz, Y-connected, wound rotor three-phase induction motor with the following test results: DC Test: 21 V, 43 A No Load Test: 400 V, 20 A, 1200 W, 60 Hz Blocked Rotor Test: 100 V, 44 A, 2700 W, 19 Hz Find R1, X1, R2, X2, and Xm of this motor? xxx₁ = 0.5xbm fy Pen Pd 51-5 NN (1-5) 1208 1 [10Marks] N wr P
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning