32. Insert the correct response from Column B to correctly complete the statement in column A: Column A a. Switches intended for isolating use only are marked b. Switches that are suitable for use as service equipment are marked c. Motor Circuit Switch d. Enclosed switches with horsepower ratings in addition to ampere ratings e. If a switch is marked with a dual horsepower rating Column B 1. For use only in motor circuits. 2. The larger horsepower rating is applicable when using dual element, time-delay fuses. 3. Suitable for use as service equipment. 4. For isolation use only-do not open under load 5. Suitable for use in motor circuits as well as for general use.

EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN:9781337516549
Author:Simmons
Publisher:Simmons
Chapter32: Standby Power Systems
Section: Chapter Questions
Problem 11R: The NEC requires that a ____________ means be provided for standby power systems. In the case of...
icon
Related questions
Question
100%
32. Insert the correct response from Column B to correctly complete the statement in column A:
Column A
a. Switches intended for isolating use only are marked
b. Switches that are suitable for use as service equipment are
marked
c. Motor Circuit Switch
d. Enclosed switches with horsepower ratings in addition to ampere
ratings
e. If a switch is marked with a dual horsepower rating
Column B
1. For use only in motor circuits.
2. The larger horsepower rating is applicable when using dual
element, time-delay fuses.
3. Suitable for use as service equipment.
4. For isolation use only-do not open under load
5. Suitable for use in motor circuits as well as for general
use.
Transcribed Image Text:32. Insert the correct response from Column B to correctly complete the statement in column A: Column A a. Switches intended for isolating use only are marked b. Switches that are suitable for use as service equipment are marked c. Motor Circuit Switch d. Enclosed switches with horsepower ratings in addition to ampere ratings e. If a switch is marked with a dual horsepower rating Column B 1. For use only in motor circuits. 2. The larger horsepower rating is applicable when using dual element, time-delay fuses. 3. Suitable for use as service equipment. 4. For isolation use only-do not open under load 5. Suitable for use in motor circuits as well as for general use.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning