A 3.2 m square footing is proposed to be used to support a 373 mm x 605 mm RC column loaded with 637 kN dead load and 856 kN live load. The bottom of the footing is 1.7 m below the ground. Assume soil weighs 19 kN/m³ and the allowable soil bearing pressure is 343 kPa. The thickness of the footing is 464 mm. f'. = 21 MPa and fy = 420 MPa. It is to be reinforced with 20 mm diameter. Use 24 kN/m3 as the unit weight of concrete. Note: For two-way shear, use an effective depth measured from the top of the footing until the top of the bottom-most bar (d3) What is the ratio of the Demand Shear Force and the Capacity in Two Way Shear? (Vu/phiVn) Answer in 4 decimal places (1.6125, 1.5140, 0.8461, etc.) You Answered Correct Answer 1.3809 margin of error +/- 1%

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
icon
Concept explainers
Question
A 3.2 m square footing is proposed to be used to support a 373 mm x 605 mm
RC column loaded with 637 kN dead load and 856 kN live load. The bottom of
the footing is 1.7 m below the ground. Assume soil weighs 19 kN/m3 and the
allowable soil bearing pressure is 343 kPa. The thickness of the footing is 464
mm. fc = 21 MPa and fy = 420 MPa. It is to be reinforced with 20 mm
diameter. Use 24 kN/m³ as the unit weight of concrete.
Note: For two-way shear, use an effective depth measured from the top of the
footing until the top of the bottom-most bar (d3)
What is the ratio of the Demand Shear Force and the Capacity in Two Way
Shear? (Vu/phiVn)
Answer in 4 decimal places (1.6125, 1.5140, 0.8461, etc.)
You Answered
Correct Answer
1.3809 margin of error +/- 1%
Transcribed Image Text:A 3.2 m square footing is proposed to be used to support a 373 mm x 605 mm RC column loaded with 637 kN dead load and 856 kN live load. The bottom of the footing is 1.7 m below the ground. Assume soil weighs 19 kN/m3 and the allowable soil bearing pressure is 343 kPa. The thickness of the footing is 464 mm. fc = 21 MPa and fy = 420 MPa. It is to be reinforced with 20 mm diameter. Use 24 kN/m³ as the unit weight of concrete. Note: For two-way shear, use an effective depth measured from the top of the footing until the top of the bottom-most bar (d3) What is the ratio of the Demand Shear Force and the Capacity in Two Way Shear? (Vu/phiVn) Answer in 4 decimal places (1.6125, 1.5140, 0.8461, etc.) You Answered Correct Answer 1.3809 margin of error +/- 1%
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Load and resistance factor design
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher: