Question
Chapter 7, Problem 7.9.2P
To determine
(a)
If the connection is adequate using Load and Resistance Factor Design (LRFD) method.
To determine
(b)
If the connection is adequate using Allowable Stress Design (ASD) method.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A structural tee bracket is attached to a column flange with six bolts as shown in Figure . All structural steel is A992. Check this connection for compliance with the AISC Specification. Assume that the bearing strength is controlled by the bearing deformation strength of 2.4dtFu.
a. Use LRFD.
b. Use ASD.
Two plates each with thickness t = 16 mm are bolted together with 6 – 22 mm diameter bolts forming
a lap connection. Bolt spacing are as follows: S1 = 40 mm, S2 = 80 mm, S3 = 100 mm. Bolt hole
diameter = 25 mm. Using A36 steel having Fy = 248 MPa and Fu = 400 MPa.
P P
S
- P
S2
S2
DETERMINE:
1. Determine the allowable load Pa based on bearing at bolt holes. (ASD)
2. Determine the ultimate load Pu based on block shear.
7.9-2
A structural tee bracket is attached to a column flange with six bolts as
shown in Figure P7.9-2. All structural steel is A992. Check this connec-
tion for compliance with the AISC Specification. Assume that the bearing
strength is controlled by the bearing deformation strength of 2.4dtF.
a. Use LRFD.
b. Use ASD.
D = 30 k
L=70 k
WWw.ma
W12 X 65
34" diameter Group A
bearing-type bolts
with threads in shear
Chapter 7 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 7 - Prob. 7.3.1PCh. 7 - Prob. 7.3.2PCh. 7 - Prob. 7.4.1PCh. 7 - Prob. 7.4.2PCh. 7 - Prob. 7.4.3PCh. 7 - Prob. 7.4.4PCh. 7 - Prob. 7.4.5PCh. 7 - Prob. 7.4.6PCh. 7 - Prob. 7.6.1PCh. 7 - Prob. 7.6.2P
Ch. 7 - Prob. 7.6.3PCh. 7 - Prob. 7.6.4PCh. 7 - Prob. 7.6.5PCh. 7 - Prob. 7.6.6PCh. 7 - Prob. 7.7.1PCh. 7 - Prob. 7.7.2PCh. 7 - Prob. 7.7.3PCh. 7 - Prob. 7.8.1PCh. 7 - Determine the adequacy of the hanger connection in...Ch. 7 - Prob. 7.9.1PCh. 7 - Prob. 7.9.2PCh. 7 - Prob. 7.9.3PCh. 7 - Prob. 7.9.4PCh. 7 - Prob. 7.9.5PCh. 7 - Prob. 7.11.1PCh. 7 - Prob. 7.11.2PCh. 7 - Prob. 7.11.3PCh. 7 - Prob. 7.11.4PCh. 7 - Prob. 7.11.5PCh. 7 - Prob. 7.11.6PCh. 7 - Prob. 7.11.7PCh. 7 - Prob. 7.11.8PCh. 7 - Prob. 7.11.9PCh. 7 - Prob. 7.11.10P
Knowledge Booster
Similar questions
- Asap plsarrow_forwardA PL 38 x 6 tension member is welded to a gusset plate as shown in figure. The steel is A36. PL ½ x 6 The design strength based on yielding is nearest to: The design strength based on rupture is nearest to: The design strength for LRFD is nearest to: The allowable strength based on yielding is nearest to: The allowable strenath based on rupture is nearest to: The allowable strength for ASD.arrow_forwardA36 steel plates are welded as shown. Determine the (a) LFRD design and the (b) ASD allowable strength of the ( c) include block shear strength in the calculations.arrow_forward
- Compute the nominal compressive strength of the member shown in Figure . Use AISC Equation E3-2 or E3-3.arrow_forwardPlease do right answer and calculation.arrow_forwardA plate with width of 420 mm and thickness of 13 mm is to be connected to a plate of the same width and thickness by 30 mm diameter bolts, as shown in the Figure 1. The holes are 3mm larger than the bolt diameter. The plate is A36 steel with yield strength Fy = 248MPa. Assume allowable tensile stress on net area is 0.60Fy. It is required to determine the value of b such that the net width along bolts 1-2-3-4 is equl to the net width along bolts 1-2-4. W = 420 mm t = 13 mm a = 64 mm c = 104 mm d = 195 mm Bolt Diameter = 30 mm Holes Diameter = 30 mm + 3 = 33 mm ?? = 248 MPa Allowable Tensile Stress on ?? = 0.60Fy a. Calculate the vaue of b in millimeters. b. Calculate the value of the net area for tension in plates in square millimeters. c. Calculate the value of P so that the allowable tensile stress on net area will not be exceeded.arrow_forward
- Situation 5. The angular section shown below is welded to a 12 mm gusset plate. Both materials are A36 steel with Fy = 250 MPa. The allowable tensile stress is 0.6Fy. The weld is E80 Electrode and 12 mm thickness. INNOVATIONS Properties of L 150x90x12: y = 50 shear stress of weld = 0.3Fu A = 2750 Allowable REVIEW INNOVATIE a K ➜ www A. 234 KN B. 349 KN b 13. What is the value of P without exceeding the allowable tensile the angle? C. 382 kN p. 413 kN 14. Find required length of the weld based on shear? A. 280 mm C. 300 mm D. 380 mm B. 320 mm 15. Find the required value of a? A. 108 mm B. 97.9 mm D. 185 mm NEW INNOVATIONS REVIEW INNOVATIOf REVIEW NEW INNOVATIONSarrow_forwardDislike if not correct.arrow_forwardTopic:Bolted Steel Connection - Civil Engineering *Use latest NSCP/NSCP 2015 formula to solve this problem *Please use hand written to solve this problem The bracket shown in the figure is supported by four 22 mm diameter bolts in single shear. The bracket is subject to an eccentric load of 150 kN. Use LRFD. Use A36 steel. Questions a) Determine the critical force on the most stressed bolt. b) Determine the nominal shear stress of the most stressed bolt.arrow_forward
- STEEL ANALYSIS full solution and final answer to 4 decimal places plsarrow_forwardA C8 × 11.5 is connected to a gusset plate with 7⁄8-inch-diameter bolts as shown in the Figure . The steel is A572 Grade 50. If the member is subjected to dead load and live load only, what is the total service load capacity if the live-to-dead load ratio is 3? Assume that Ae = 0.85An.a. Use LRFD.b. Use ASD.arrow_forwardQ2: aluminum rod AB (G 27GPA) brass rod BD (G = 39GPA). portion CD of the brass rod is hollow and has an inner diameter of 40 mm, Determine: a) the angle of twist at A. b) maximum shear stress of rod AD c) torque diagram d) angle of twist diagramarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning