Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN: 9781337094740
Author: Segui, William T.
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 7, Problem 7.7.1P
To determine
(a)
The number of bolts required using LRFD.
To determine
(b)
The number of bolts required using ASD.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Solve
An ISA 125 x 75 x 8 is welded with the flange of a
column ISHB 300. The bracket carries a factored
load of 75 kN at a distance of 38 mm as shown in
figure. Design the connection. Use Fe410 grade
steel. Field weld is used.
250
125
125
ISHB 300
38 75kN
300
Flange width of ISHB 300 = 250 mm.
-ISA 125 x 75 x 8
Problem. A bolted connection shown consists of two plates 300 mm x 12 mm
connected by 4 - 22 mm diameter bolts.
12 mm bolts
t=12 mm
t=12 mm
P.
P-
P 300
75
75
75
Edge distances -75 mm
dhole for tensile and rupture d, +3 mm
dnole for bearing strength for L- de +1.5 mm
Fy 248 MPa
F.- 400 MPa
A plate 1⁄2 3 4 of A36 steel is used as a tension member to carry a service dead load of 6 kips and a service live load of 18 kips. It is to be attached to a 3⁄8-inch gusset plate, as shown in Figure. Design a welded connection.
Chapter 7 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 7 - Prob. 7.3.1PCh. 7 - Prob. 7.3.2PCh. 7 - Prob. 7.4.1PCh. 7 - Prob. 7.4.2PCh. 7 - Prob. 7.4.3PCh. 7 - Prob. 7.4.4PCh. 7 - Prob. 7.4.5PCh. 7 - Prob. 7.4.6PCh. 7 - Prob. 7.6.1PCh. 7 - Prob. 7.6.2P
Ch. 7 - Prob. 7.6.3PCh. 7 - Prob. 7.6.4PCh. 7 - Prob. 7.6.5PCh. 7 - Prob. 7.6.6PCh. 7 - Prob. 7.7.1PCh. 7 - Prob. 7.7.2PCh. 7 - Prob. 7.7.3PCh. 7 - Prob. 7.8.1PCh. 7 - Determine the adequacy of the hanger connection in...Ch. 7 - Prob. 7.9.1PCh. 7 - Prob. 7.9.2PCh. 7 - Prob. 7.9.3PCh. 7 - Prob. 7.9.4PCh. 7 - Prob. 7.9.5PCh. 7 - Prob. 7.11.1PCh. 7 - Prob. 7.11.2PCh. 7 - Prob. 7.11.3PCh. 7 - Prob. 7.11.4PCh. 7 - Prob. 7.11.5PCh. 7 - Prob. 7.11.6PCh. 7 - Prob. 7.11.7PCh. 7 - Prob. 7.11.8PCh. 7 - Prob. 7.11.9PCh. 7 - Prob. 7.11.10P
Knowledge Booster
Similar questions
- Determine the adequacy of the hanger connection in Figure P7.8-2 Account for prying action. a. Use LRFD. b. Use ASD.arrow_forwardUse load and resistance factor design and select a W shape with a nominal depth of 10 inches (a W 10) to resist a dead load of 175 kips and a live load of 175 kips. The connection will be through the flanges with two lines of 11 4 -inch-diameter bolts in each flange, as shown in Figure P3.6-6. Each line contains more than two bolts. The length of the member is 30 feet. Use A588 steal.arrow_forwardA tension connection consists of A36 steel double angles (two L4x4x1/4 shapes, or 2L4x4x1/4) fastened to a 4x10 No. 2 Red Oak member with a single row of four 0.875 inch A307 bolts. The connection is subjected to normal temperatures but wet in-service conditions. Assume the group action factor is C,=0.95 and the geometry factor is Ca=1. The controlling ASD load combination is D+ L where L is from occupancy. Elevation Cross Section L4x4x1/4 L4x4x1/4 Pa Р. 2L4x4x1/4 4х10 4x10 Plan L4x4x1/4 Pa/2 Pa 4x10 L4x4x1/4 Pa/2 • Determine the load, Pa, that the connection can support based on tension strength of the 4x10. Pa=. lb • Determine the load, Pa, that the connection can support based on gross tension yield of the double angles. The ASD design strength for gross tension yield is F,A,/1.67 where F=36 ksi, A,=1.93 in² for each L4x4x1/4. Pa=. lbarrow_forward
- Check the adequacy of the rigid beam to column welded connection shown. The beam is a 410 UB 53.7 of Grade 300 PLUS, the electrode is E41xx SP and (V*, M*) = (36 kN, 166 kNm). (Hint: Check the adequacy also against the minimum values required in AS4100). It M* 393arrow_forwardProblem 7: The load that will be applied to the connection shown has a live load - to - dead load ratio of 3.0. Investigate all limit states. All structural steel is A36, and the weld is a 1/4-inch fillet weld with E70 electrodes. Note that the tension member is a double-angle shape, and both of the angles are welded as shown. Use ASD. Determine the following. 5" 5" 2L5 X 32 X 5/16 LLBB -t = ³/8" Maximum service load that can be applied without exceeding the allowable capacity on yielding on gross area of the tension member (double angle). Maximum service load that can be applied without exceeding the allowable fracture on the net area of the tension member (double angle). Maximum service load that can be applied without exceeding the allowable block shear strength. Considering the weld metal and base metal strength, calculate the maximum service load that can be applied.arrow_forwardDesign a welded connection. The given loads are service loads. Use Fy =50 ksi for the angle tension member and Fy=36 ksi for the gusset plate. Show your results on a sketch, complete with dimensions. a. Use LRFD. b. Use ASD.arrow_forward
- A C130x10 tension member is welded to a plate as shown in the figure. The channel is of Grade 350W steel. The channel is welded on both sides with 110 mm long fillet weld. Assume the weld does not govern the capacity, calculate the factored tension resistance of the channel. The tension resistance is not governed by the plate. C130 XI0arrow_forwardSOLVE FOR1 HRarrow_forwardAccording to given dataPlease solve the below question. ASAP and clear and accurate , Dont attempt wrongarrow_forward
- subject: Steel Design 1. A992 steel is used for the tension member shown. The bolts are 3/4 inch in diameter. The connection is to a 3/8 in.thick gusset plate. a. Determine the nominal strength based on the gross area. b. Determine the nominal strength based on the effective net are.arrow_forwardDetermine the maximum service load, P, that can be applied if the live load to dead load ratio is 2.5. Each component if PL 5/8x7 of A242 steel (Fy = 50 ksi and Fu = 70 ksi). The weld is a 5/16-inch fillet weld, E70 electrode. Use LRFD. Note: Block shear cannot occur for this connection.arrow_forwardThe billboard post support a 5KN dead load as shown. The cantilever beam and the brace is pinnedconnected to the post. Assume that the connections along the cap and the cap plate is adequate, as well asthe gusset plate and the cap plate. Use LRFD design considerations.a.) Determine the ultimate tensile force the brace carries. b.) Determine the adequacy of Connection 1 the bolt where 2- 16mm Ø A325 hex bolt and the plateswhere A36 steel. c.) If the connection at Connection 1 will be a welded connection what will be the adequate thickness ofthe weld. Note that the welds are only applied at the sides of the cap plate. Use electrode 70 for theweld. d.) Determine the adequacy of the connection due to shear and tension in Connection 2 if the bolts were4- 12mm Ø A325 hex bolt.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Steel Design (Activate Learning with these NEW ti...Civil EngineeringISBN:9781337094740Author:Segui, William T.Publisher:Cengage Learning
Steel Design (Activate Learning with these NEW ti...
Civil Engineering
ISBN:9781337094740
Author:Segui, William T.
Publisher:Cengage Learning