Question
Chapter 7, Problem 7.11.10P
To determine
The design of a tension member using LRFD method.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Topic:Welded Connection - Civil Engineering -Steel Design
*Use latest NSCP/NSCP 2015 formula to solve this problem
*Please use hand written to solve this problem
A channel is used as a tension member with the web of the channel welded to a 9.5 mm thick gusset plate as shown in the figure. The tension member is subjected to the following axial loads. Use LRFD
Service dead load = 200 kN
Wind load = 276 kN
Service live load = 260 kN
For channel:
Fy = 345 MPa
For gusset plate:
Fy = 248 MPa Fu = 400 MPa
Size of E 70 electrodes = 4 mm
Ultimate tensile strength of E 70 electrodes = 480;
Fw = 0.6(480)
Questions :
a) Determine the design factored tensile force.
b) Determine the length of longitudinal welds "L".
c) Determine the block shear strength of the gusset plate.
Considering the following steel connection. The plates in Pink are 9mm steel plates. The middle plate (Yellow) is
18mm thick. The width of the plate is 100mm. The maximum allowable tension stresses on any of the plates is
100Mpa in Gross Area Yielding and 150 Mpa for Net Area or Tension Rupture. The bolts used are 8mm in
diameter, the holes are 10mm in diameter, no need to add 1.6mm. The bolts allow a maximum of 280 Mpa of
shear. Determine the maximum allowable "P" of the connection in kN.
Topic:Welded Connection - Civil Engineering -Steel Design
*Use latest NSCP/NSCP 2015 formula to solve this problem
*Use attached formula picture for block shear
*Please use hand written to solve this problem
A channel is used as a tension member with the web of the channel welded to a 9.5 mm thick gusset plate as shown in the figure. The tension member is subjected to the following axial loads. Use LRFD
Service dead load = 200 kN
Wind load = 276 kN
Service live load = 260 kN
For channel:
Fy = 345 MPa
For gusset plate:
Fy = 248 MPa Fu = 400 MPa
Size of E 70 electrodes = 4 mm
Ultimate tensile strength of E 70 electrodes = 480;
Fw = 0.6(480)
Questions :
a) Determine the design factored tensile force.
b) Determine the length of longitudinal welds "L".
c) Determine the block shear strength of the gusset plate.
Chapter 7 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 7 - Prob. 7.3.1PCh. 7 - Prob. 7.3.2PCh. 7 - Prob. 7.4.1PCh. 7 - Prob. 7.4.2PCh. 7 - Prob. 7.4.3PCh. 7 - Prob. 7.4.4PCh. 7 - Prob. 7.4.5PCh. 7 - Prob. 7.4.6PCh. 7 - Prob. 7.6.1PCh. 7 - Prob. 7.6.2P
Ch. 7 - Prob. 7.6.3PCh. 7 - Prob. 7.6.4PCh. 7 - Prob. 7.6.5PCh. 7 - Prob. 7.6.6PCh. 7 - Prob. 7.7.1PCh. 7 - Prob. 7.7.2PCh. 7 - Prob. 7.7.3PCh. 7 - Prob. 7.8.1PCh. 7 - Determine the adequacy of the hanger connection in...Ch. 7 - Prob. 7.9.1PCh. 7 - Prob. 7.9.2PCh. 7 - Prob. 7.9.3PCh. 7 - Prob. 7.9.4PCh. 7 - Prob. 7.9.5PCh. 7 - Prob. 7.11.1PCh. 7 - Prob. 7.11.2PCh. 7 - Prob. 7.11.3PCh. 7 - Prob. 7.11.4PCh. 7 - Prob. 7.11.5PCh. 7 - Prob. 7.11.6PCh. 7 - Prob. 7.11.7PCh. 7 - Prob. 7.11.8PCh. 7 - Prob. 7.11.9PCh. 7 - Prob. 7.11.10P
Knowledge Booster
Similar questions
- A 3/4 in (thickness) X 5 in (height) steel plate is connected to another one through two bolts of nominal diameter 1/2 in in a zig-zag arrangement as shown. Determine the tensile strength capacity Pu of the connection. Review the three limit-states: (a) yielding in the gross area, (b) rup- ture in the overall net tensile area, and (c) block shear strength.arrow_forwardGive me right solutionarrow_forwardA tension connection consists of A36 steel double angles (two L4x4x1/4 shapes, or 2L4x4x1/4) fastened to a 4x10 No. 2 Red Oak member with a single row of four 0.875 inch A307 bolts. The connection is subjected to normal temperatures but wet in-service conditions. Assume the group action factor is C,=0.95 and the geometry factor is Ca=1. The controlling ASD load combination is D+ L where L is from occupancy. Elevation Cross Section L4x4x1/4 L4x4x1/4 Pa Р. 2L4x4x1/4 4х10 4x10 Plan L4x4x1/4 Pa/2 Pa 4x10 L4x4x1/4 Pa/2 • Determine the load, Pa, that the connection can support based on tension strength of the 4x10. Pa=. lb • Determine the load, Pa, that the connection can support based on gross tension yield of the double angles. The ASD design strength for gross tension yield is F,A,/1.67 where F=36 ksi, A,=1.93 in² for each L4x4x1/4. Pa=. lbarrow_forward
- The largest load P that can be applied is approximately equals: Arca - 0.00126 m oall - 45 MPa a)57 kN B Aren- 0.0007 m b)60 kN Weld allowable strength - 60 kN all - 95 MPa c)67 kN d)50 kNarrow_forwardQuestion 1 Check that the medium-term load of 38 kN applied to the spaced column shown in below complies with the design requirements of BS 5268-2. The column consists of two 38 x 150 C22 timbers 76 mm apart. All joints are glued and intermediate packs are 250 mm long. suitable connection #### x ->89² 6:38. Y T -end blocking AP 100 intermediate blocking L₂ 1₁ x W L W EFH 400 m 38kN medium term load -ICHICHID -200 600 600 600 600 600 600 200 38kN medium term loadarrow_forwardUse an elastic analysis and determine the maximum load per inch of weld.arrow_forward
- Hi! Can you solve that question ?arrow_forwardanswer item 3 only Diameter 100.5mm thickness 10.25 mm axial stree 451 mpaarrow_forwardTopic:Welded Connection - Civil Engineering -Steel Design *Use latest NSCP/NSCP 2015 formula to solve this problem *Please use hand written to solve this problem A tension member consists of a double angle section with long legs back to back. The angles are attached to a 9.5 mm thick gusset plate. Fu = 400 MPa Fy = 248 MPa for angular section. Fw = 480 MPa for 8 mm fillet weld. Reduction factor U = 0.80 Prop. of One Angle L 125m x 75m x 12.7 m A= 2419 mm2 y=44.45 mm Questions: a) Compute the design strength capacity of one angle. b) Compute the base metal shear strength (gusset plate) per unit length. c) Compute the length L1 and L2.arrow_forward