Question
Chapter 7, Problem 7.4.1P
To determine
(a)
The specifications of all spacing and edge distance.
To determine
(b)
The design strength in shear and bearing.
To determine
(b)
The allowable strength on shear and bearing.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Asap pls
3. A plate with width of 300mm and thickness of 20mm is to be connected to two plates
of the same width with half the thickness by 24mm diameter bolts, as shown. The
rivet holes have a diameter of 2mm larger than the rivet diameter. The plate is A36
steel with yield strength F,-248MPa and ultimate strength F,-400MPa.
a. Determine the design strength of the section.
b. Determine the allowable strength of the section
24mm
30mm
Considering the following steel connection. The plates in Pink are 9mm steel plates. The middle plate (Yellow) is
18mm thick. The width of the plate is 100mm. The maximum allowable tension stresses on any of the plates is
100Mpa in Gross Area Yielding and 150 Mpa for Net Area or Tension Rupture. The bolts used are 8mm in
diameter, the holes are 10mm in diameter, no need to add 1.6mm. The bolts allow a maximum of 280 Mpa of
shear. Determine the maximum allowable "P" of the connection in kN.
Chapter 7 Solutions
Steel Design (Activate Learning with these NEW titles from Engineering!)
Ch. 7 - Prob. 7.3.1PCh. 7 - Prob. 7.3.2PCh. 7 - Prob. 7.4.1PCh. 7 - Prob. 7.4.2PCh. 7 - Prob. 7.4.3PCh. 7 - Prob. 7.4.4PCh. 7 - Prob. 7.4.5PCh. 7 - Prob. 7.4.6PCh. 7 - Prob. 7.6.1PCh. 7 - Prob. 7.6.2P
Ch. 7 - Prob. 7.6.3PCh. 7 - Prob. 7.6.4PCh. 7 - Prob. 7.6.5PCh. 7 - Prob. 7.6.6PCh. 7 - Prob. 7.7.1PCh. 7 - Prob. 7.7.2PCh. 7 - Prob. 7.7.3PCh. 7 - Prob. 7.8.1PCh. 7 - Determine the adequacy of the hanger connection in...Ch. 7 - Prob. 7.9.1PCh. 7 - Prob. 7.9.2PCh. 7 - Prob. 7.9.3PCh. 7 - Prob. 7.9.4PCh. 7 - Prob. 7.9.5PCh. 7 - Prob. 7.11.1PCh. 7 - Prob. 7.11.2PCh. 7 - Prob. 7.11.3PCh. 7 - Prob. 7.11.4PCh. 7 - Prob. 7.11.5PCh. 7 - Prob. 7.11.6PCh. 7 - Prob. 7.11.7PCh. 7 - Prob. 7.11.8PCh. 7 - Prob. 7.11.9PCh. 7 - Prob. 7.11.10P
Knowledge Booster
Similar questions
- A double-angle shape is shown in the figure. The steel is A36, and the holes are for 2-inch-diameter bolts. Assume that A₂ = 0.75An. Ae 1 2 Determine the design tensile strength for LRFD. Determine the allowable strength for ASD. CIVIL ENGINEERING - STEEL DESIGN AL Section 2L5 x 3 x 516 LLBBarrow_forwardSTEEL ANALYSIS full solution and final answer to 4 decimal places plsarrow_forwardA C8 x 11.5 is connected to a gusset plate with 7/8 inch diameter bolts as shown in Figure P3.2-3. The steel is A572 Grade 50. If the member is subjected to a dead load and live load only, what is the total service load capacity if the live to dead load ratio is 3? Assume that Ae=0.85An. Use LRFD and ASD.arrow_forward
- A PL 38 X 6 tension member is welded to a gusset plate as shown. The steel is A36 (Fy = 36ksi, Fu = 58ksi). a. The design strength, Pu based on gross area b. The design strength, Pu based on effective area PL % x 6 3/8" 6" Cross Sectional area of PL3/8x6 a) Blank 1 b) Blank 2 Blank 1 Add your answer Blank 2 Add your answerarrow_forwardWideFlange Section: W 16x67arrow_forwardTensile Strength A PL 3/8 x 7 tension member is connected with three 1-inch-diameter bolts, as shown in Figure P3.2-1. The steel is A36. Assume that Ae = An %3D and compute the following. a. The design strength for LRFD. b. The allowable strength for ASD. PL %x7 O o oarrow_forward
- A tension plate shown below is used to support suspended load "T". Gusset Plate Fy Fu = 400 MPa = 248 MPa 200 mm a) Determine the allowable tensile capacity of the plate if L = 240 mm. (Assume weld strength is satisfactory).arrow_forwardA C8 × 11.5 is connected to a gusset plale with 22 mm diameter bolts as shown. The steel is A572 Grade 50. If the member is subjected to dead load and live load only, what is the total scrvice load capacity if the live-to-dead load ratio is 3? Assume that Ae = 0.85Ap. a. Use LRFD. b. Use ASD. Properties of A572 Grade 50: Fy = 345 MPa C8 × 11.5 Fu = 448 MPa Properties of C8 x 11.5: Ag = 2,181 mm? br = 57.4 mm d= 203.2 mm Lw = 5.6 mm lf = 9.9 mmarrow_forwardGive me right solution according to the question... Urgent pleasearrow_forward
- Please answerarrow_forwardProblem # 6.0 For the tension member shown, compute the tensile design strength. Weld -6" PL 4X6 A36 steelarrow_forwardTwo plates each with thickness t = 16 mm are bolted together with 6 – 22 mm diameter bolts forming a lap connection. Bolt spacing are as follows: S1 = 40 mm, S2 = 80 mm, S3 = 100 mm. Bolt hole diameter = 25 mm. Using A36 steel having Fy = 248 MPa and Fu = 400 MPa. P P S - P S2 S2 DETERMINE: 1. Determine the allowable load Pa based on bearing at bolt holes. (ASD) 2. Determine the ultimate load Pu based on block shear.arrow_forward