Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
8th Edition
ISBN: 9780073398174
Author: Yunus A. Cengel Dr., Michael A. Boles
Publisher: McGraw-Hill Education
bartleby

Videos

Question
Book Icon
Chapter 5.5, Problem 82P

(a)

To determine

The temperature of the air at the exit.

(a)

Expert Solution
Check Mark

Answer to Problem 82P

The temperature of the air at the exit is 16.2°F.

Explanation of Solution

Draw the schematic diagram for the evaporator section.

Thermodynamics: An Engineering Approach, Chapter 5.5, Problem 82P

Write the formula to calculate the specific enthalpy of steam (h) from tables.

h=hf+x(hfg) (I)

Here, specific enthalpy of saturated liquid is hf, specific enthalpy of saturated liquid-vapor mixture is hfg and dryness fraction of water is x.

Write the ideal gas equation for specific volume of air (v).

v=RTP (II)

Here, gas constant for air is R, temperature of air is T, and the pressure of air is P.

Calculate the volume flow rate (V˙1) of the air at the inlet.

V˙1=m˙av1 (III)

Here, mass flow rate of air is m˙a and specific volume of air is v1.

Write the expression for the mass balance.

minmout=Δm

minmout=0(For steady state) (IV)

Here, mass of the fluid entering into the system is min, mass of fluid leaving out of the system is mout and change in mass is Δm.

Write the energy rate balance equation for a control volume.

E˙inE˙out=dE˙system/dt

E˙inE˙out=0(For steady state) (V)

Here, total energy rate at inlet is E˙in, total energy rate at outlet is E˙out and change in net energy rate is dE˙system/dt.

Conclusion:

Refer Table A-1E, “Gas constant of common gases”, obtain the gas constant of air as 0.3704psiaft3/lbmR.

Refer Table A-2E, “Ideal – gas specific heats of common gases”, obtain the constant pressure specific heat of air as 0.240Btu/lbm.°F.

Refer Table A-12E, “Saturated R-134a-Pressure table”, obtain the properties of saturated R-134a at pressure (P3) of 20 psia.

hf=11.436Btu/lbmhfg=91.302 Btu/lbm

Substitute 11.436Btu/lbm for hf, 0.3 for x3 and 91.302Btu/lbm for hfg in Equation (I).

h3=11.436Btu/lbm+(0.3)91.302Btu/lbm=38.83Btu/lbm

Refer Table A-12E, “Saturated R-134a-Pressure table”, obtain the specific enthalpy (h4) of saturated vapor of R-134aat pressure (P4) of 20 psia as 102.74Btu/lbm.

Substitute 0.3704psiaft3/lbmR for R, 90°F for T1, and 14.7psia for P1 in Equation (II).

v1=RT1P1=0.3704psiaft3/lbmR(90°F)14.7psia=0.3704psiaft3/lbmR(90+460)R14.7psia

v1=13.86ft3/lbm

Substitute 200ft3/min for V˙1, and 13.86ft3/lbm for v1 in Equation (III).

m˙a=200ft3/min13.86ft3/lbm=14.43lbm/min

Rewrite Equation (I) for the mass flow rate of air (m˙a).

m˙1=m˙2=m˙a

Here, mass flow rate of air at inlet is m˙1 and mass flow rate of air at outlet is m˙2.

Rewrite the Equation (I) for the mass flow rate of R-134a (m˙R).

m˙3=m˙4=m˙R

Here, mass flow rate of R-134a at inlet is m˙3, and mass flow rate of R-134a at outlet is m˙4.

Rewrite Equation (II) for the energy balance in the steam heating system.

m˙1h1+m˙3h3=m˙2h2+m˙4h4 (V)

Substitute m˙a for m˙1, m˙a for m˙2, m˙R for m˙3, and m˙R for m˙4 in Equation (V).

m˙ah1+m˙Rh3=m˙ah2+m˙Rh4m˙R(h3h4)=m˙a(h2h1)m˙R(h3h4)=m˙acp(T2T1)

T2=T1+m˙R(h3h4)m˙acp (VI)

Here, specific enthalpy of air at the inlet is h1, specific enthalpy of air at the outlet is h2, constant pressure specific heat of air is cp, temperature of air at inlet is T1 and temperature of air at the outlet is T2.

Substitute 38.83 Btu/lbm for h3, 102.74 Btu/lbm for h4, 0.240 Btu/lbm.°F for cp, 4 lbm/min for m˙R, 14.43 lbm/min for m˙a, and 90°F for T1 in Equation (VI).

T2=90°F+4 lbm/min×(38.83 Btu/lbm102.74 Btu/lbm)14.43 lbm/min×0.240 Btu/lbm.°F=16.2°F

Thus, the temperature of the air at the exit is 16.2°F.

(b)

To determine

The rate of heat transfer from the air to the refrigerant.

(b)

Expert Solution
Check Mark

Answer to Problem 82P

The rate of heat transfer from the air to the refrigerant is 255.6Btu/min.

Explanation of Solution

Write the formula to calculate the rate of heat transfer from the air to the refrigerant (Qair,out).

Qair,out=m˙acp(T2T1) (VII)

Conclusion:

Substitute 14.43lbm/min for m˙a, 0.240Btu/lbm°F for cp, 16.24°F for T2 and 90°F for T1 in Equation (VII).

Qair,out=(14.43lbm/min)(0.240Btu/lbm°F)(16.24°F90°F)=255.6Btu/min

Thus, the rate of heat transfer from the air to the refrigerant is 255.6Btu/min.

Want to see more full solutions like this?

Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!

Chapter 5 Solutions

Thermodynamics: An Engineering Approach

Ch. 5.5 - 5–11 A spherical hot-air balloon is initially...Ch. 5.5 - A desktop computer is to be cooled by a fan whose...Ch. 5.5 - 5–13 A pump increases the water pressure from 100...Ch. 5.5 - Refrigerant-134a enters a 28-cm-diameter pipe...Ch. 5.5 - Prob. 15PCh. 5.5 - Prob. 16PCh. 5.5 - 5–17C What is flow energy? Do fluids at rest...Ch. 5.5 - How do the energies of a flowing fluid and a fluid...Ch. 5.5 - Prob. 19PCh. 5.5 - Prob. 20PCh. 5.5 - Refrigerant-134a enters the compressor of a...Ch. 5.5 - Steam is leaving a pressure cooker whose operating...Ch. 5.5 - A diffuser is an adiabatic device that decreases...Ch. 5.5 - The kinetic energy of a fluid increases as it is...Ch. 5.5 - Prob. 25PCh. 5.5 - Air enters a nozzle steadily at 50 psia, 140F, and...Ch. 5.5 - The stators in a gas turbine are designed to...Ch. 5.5 - The diffuser in a jet engine is designed to...Ch. 5.5 - Air at 600 kPa and 500 K enters an adiabatic...Ch. 5.5 - Prob. 30PCh. 5.5 - Prob. 31PCh. 5.5 - Air at 13 psia and 65F enters an adiabatic...Ch. 5.5 - Carbon dioxide enters an adiabatic nozzle steadily...Ch. 5.5 - Refrigerant-134a at 700 kPa and 120C enters an...Ch. 5.5 - Prob. 35PCh. 5.5 - Refrigerant-134a enters a diffuser steadily as...Ch. 5.5 - Prob. 38PCh. 5.5 - Air at 80 kPa, 27C, and 220 m/s enters a diffuser...Ch. 5.5 - 5–40C Consider an air compressor operating...Ch. 5.5 - Prob. 41PCh. 5.5 - Somebody proposes the following system to cool a...Ch. 5.5 - 5–43E Air flows steadily through an adiabatic...Ch. 5.5 - Prob. 44PCh. 5.5 - Prob. 45PCh. 5.5 - Steam flows steadily through an adiabatic turbine....Ch. 5.5 - Prob. 48PCh. 5.5 - Steam flows steadily through a turbine at a rate...Ch. 5.5 - Prob. 50PCh. 5.5 - Carbon dioxide enters an adiabatic compressor at...Ch. 5.5 - Prob. 52PCh. 5.5 - 5–54 An adiabatic gas turbine expands air at 1300...Ch. 5.5 - Prob. 55PCh. 5.5 - Prob. 56PCh. 5.5 - Air enters the compressor of a gas-turbine plant...Ch. 5.5 - Why are throttling devices commonly used in...Ch. 5.5 - Would you expect the temperature of air to drop as...Ch. 5.5 - Prob. 60PCh. 5.5 - During a throttling process, the temperature of a...Ch. 5.5 - Refrigerant-134a is throttled from the saturated...Ch. 5.5 - A saturated liquidvapor mixture of water, called...Ch. 5.5 - Prob. 64PCh. 5.5 - A well-insulated valve is used to throttle steam...Ch. 5.5 - Refrigerant-134a enters the expansion valve of a...Ch. 5.5 - Prob. 68PCh. 5.5 - Consider a steady-flow heat exchanger involving...Ch. 5.5 - Prob. 70PCh. 5.5 - Prob. 71PCh. 5.5 - Prob. 72PCh. 5.5 - Prob. 73PCh. 5.5 - Prob. 74PCh. 5.5 - Prob. 76PCh. 5.5 - Steam is to be condensed on the shell side of a...Ch. 5.5 - Prob. 78PCh. 5.5 - Air (cp = 1.005 kJ/kgC) is to be preheated by hot...Ch. 5.5 - Prob. 80PCh. 5.5 - Refrigerant-134a at 1 MPa and 90C is to be cooled...Ch. 5.5 - Prob. 82PCh. 5.5 - An air-conditioning system involves the mixing of...Ch. 5.5 - The evaporator of a refrigeration cycle is...Ch. 5.5 - Steam is to be condensed in the condenser of a...Ch. 5.5 - Steam is to be condensed in the condenser of a...Ch. 5.5 - Two mass streams of the same ideal gas are mixed...Ch. 5.5 - Prob. 89PCh. 5.5 - A 110-volt electrical heater is used to warm 0.3...Ch. 5.5 - The fan on a personal computer draws 0.3 ft3/s of...Ch. 5.5 - Prob. 92PCh. 5.5 - 5–93 A scaled electronic box is to be cooled by...Ch. 5.5 - Prob. 94PCh. 5.5 - Prob. 95PCh. 5.5 - Prob. 96PCh. 5.5 - Prob. 97PCh. 5.5 - A computer cooled by a fan contains eight PCBs,...Ch. 5.5 - Prob. 99PCh. 5.5 - A long roll of 2-m-wide and 0.5-cm-thick 1-Mn...Ch. 5.5 - Prob. 101PCh. 5.5 - Prob. 102PCh. 5.5 - A house has an electric heating system that...Ch. 5.5 - Steam enters a long, horizontal pipe with an inlet...Ch. 5.5 - Refrigerant-134a enters the condenser of a...Ch. 5.5 - Prob. 106PCh. 5.5 - Water is heated in an insulated, constant-diameter...Ch. 5.5 - Prob. 108PCh. 5.5 - Air enters the duct of an air-conditioning system...Ch. 5.5 - A rigid, insulated tank that is initially...Ch. 5.5 - 5–113 A rigid, insulated tank that is initially...Ch. 5.5 - Prob. 114PCh. 5.5 - A 0.2-m3 rigid tank equipped with a pressure...Ch. 5.5 - Prob. 116PCh. 5.5 - Prob. 117PCh. 5.5 - Prob. 118PCh. 5.5 - Prob. 119PCh. 5.5 - An air-conditioning system is to be filled from a...Ch. 5.5 - Oxygen is supplied to a medical facility from ten...Ch. 5.5 - Prob. 122PCh. 5.5 - A 0.3-m3 rigid tank is filled with saturated...Ch. 5.5 - Prob. 124PCh. 5.5 - Prob. 125PCh. 5.5 - Prob. 126PCh. 5.5 - The air-release flap on a hot-air balloon is used...Ch. 5.5 - An insulated 0.15-m3 tank contains helium at 3 MPa...Ch. 5.5 - An insulated 40-ft3 rigid tank contains air at 50...Ch. 5.5 - A vertical pistoncylinder device initially...Ch. 5.5 - A vertical piston-cylinder device initially...Ch. 5.5 - Prob. 135RPCh. 5.5 - Prob. 136RPCh. 5.5 - Air at 4.18 kg/m3 enters a nozzle that has an...Ch. 5.5 - An air compressor compresses 15 L/s of air at 120...Ch. 5.5 - 5–139 Saturated refrigerant-134a vapor at 34°C is...Ch. 5.5 - A steam turbine operates with 1.6 MPa and 350C...Ch. 5.5 - Prob. 141RPCh. 5.5 - Prob. 142RPCh. 5.5 - Prob. 143RPCh. 5.5 - Steam enters a nozzle with a low velocity at 150C...Ch. 5.5 - Prob. 146RPCh. 5.5 - Prob. 147RPCh. 5.5 - Prob. 148RPCh. 5.5 - Prob. 149RPCh. 5.5 - Cold water enters a steam generator at 20C and...Ch. 5.5 - Prob. 151RPCh. 5.5 - An ideal gas expands in an adiabatic turbine from...Ch. 5.5 - Prob. 153RPCh. 5.5 - Prob. 154RPCh. 5.5 - Prob. 155RPCh. 5.5 - Prob. 156RPCh. 5.5 - Prob. 157RPCh. 5.5 - Prob. 158RPCh. 5.5 - Prob. 159RPCh. 5.5 - Prob. 160RPCh. 5.5 - Prob. 161RPCh. 5.5 - Prob. 162RPCh. 5.5 - Prob. 163RPCh. 5.5 - The ventilating fan of the bathroom of a building...Ch. 5.5 - Determine the rate of sensible heat loss from a...Ch. 5.5 - An air-conditioning system requires airflow at the...Ch. 5.5 - The maximum flow rate of standard shower heads is...Ch. 5.5 - An adiabatic air compressor is to be powered by a...Ch. 5.5 - Prob. 171RPCh. 5.5 - Prob. 172RPCh. 5.5 - Prob. 173RPCh. 5.5 - Prob. 174RPCh. 5.5 - Prob. 175RPCh. 5.5 - A tank with an internal volume of 1 m3 contains...Ch. 5.5 - A liquid R-134a bottle has an internal volume of...Ch. 5.5 - Prob. 179RPCh. 5.5 - Prob. 181RPCh. 5.5 - Prob. 182RPCh. 5.5 - Prob. 184RPCh. 5.5 - A pistoncylinder device initially contains 1.2 kg...Ch. 5.5 - In a single-flash geothermal power plant,...Ch. 5.5 - The turbocharger of an internal combustion engine...Ch. 5.5 - A building with an internal volume of 400 m3 is to...Ch. 5.5 - Prob. 189RPCh. 5.5 - Prob. 190RPCh. 5.5 - Prob. 191RPCh. 5.5 - Prob. 192FEPCh. 5.5 - Prob. 193FEPCh. 5.5 - An adiabatic heat exchanger is used to heat cold...Ch. 5.5 - A heat exchanger is used to heat cold water at 15C...Ch. 5.5 - An adiabatic heat exchanger is used to heat cold...Ch. 5.5 - In a shower, cold water at 10C flowing at a rate...Ch. 5.5 - Prob. 198FEPCh. 5.5 - Hot combustion gases (assumed to have the...Ch. 5.5 - Steam expands in a turbine from 4 MPa and 500C to...Ch. 5.5 - Steam is compressed by an adiabatic compressor...Ch. 5.5 - Refrigerant-134a is compressed by a compressor...Ch. 5.5 - Prob. 203FEPCh. 5.5 - Prob. 204FEPCh. 5.5 - Air at 27C and 5 atm is throttled by a valve to 1...Ch. 5.5 - Steam at 1 MPa and 300C is throttled adiabatically...Ch. 5.5 - Air is to be heated steadily by an 8-kW electric...
Knowledge Booster
Background pattern image
Mechanical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Text book image
Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press
Text book image
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON
Text book image
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education
Text book image
Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY
Text book image
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Text book image
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY
Power Plant Explained | Working Principles; Author: RealPars;https://www.youtube.com/watch?v=HGVDu1z5YQ8;License: Standard YouTube License, CC-BY