Thermodynamics: An Engineering Approach ( 9th International Edition ) ISBN:9781260092684
9th Edition
ISBN: 9781260048667
Author: Yunus A. Cengel Dr.; Michael A. Boles
Publisher: McGraw-Hill Education
expand_more
expand_more
format_list_bulleted
Textbook Question
Chapter 11.10, Problem 132RP
Derive a relation for the COP of the two-stage refrigeration system with a flash chamber as shown in Fig. 11–14 in terms of the enthalpies and the quality at state 6. Consider a unit mass in the condenser.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
(a)
Figure 3 shows a refrigeration system using Refrigerant-134a as the refrigerant has a
compressor that consumes 800 W of power when operational. The refrigerant enters the
evaporator at 100 kPa as saturated mixture of quality 25% and leaves the condenser the same
pressure as at a temperature of -26°C.
Determine the rate of heat rejected (Q.) at the condenser and the COP of the refrigerator. The
mass flow rate of the refrigerant is 0.005 kg/s.
condenser
expansion
compressor
valve
evaporator
Figure 3: Refrigeration system
(b)
After graduation, you decided to work overseas to experience living in a country with four
seasons. Your neighbour, knowing that you are an engineer asked your help to install a heat
pump system for his house. He wanted to always maintain the temperature in his house at
24°C during winter. In that area during winters, average outside temperature is -3°C. He also
has an underground water well with average water temperature of 10°C during winter.
You estimated that…
A refrigeration system using R-22 has a capacity of 320 kW of refrigeration. The evaporating temperature is -10C and the condensing temperature is 40C.Calculate the fraction of vapor in the mixture before the evaporator.
اريد حل كتابة يد
Chapter 11 Solutions
Thermodynamics: An Engineering Approach ( 9th International Edition ) ISBN:9781260092684
Ch. 11.10 - Why do we study the reversed Carnot cycle even...Ch. 11.10 - Why is the reversed Carnot cycle executed within...Ch. 11.10 - A steady-flow Carnot refrigeration cycle uses...Ch. 11.10 - Refrigerant-134a enters the condenser of a...Ch. 11.10 - Does the ideal vapor-compression refrigeration...Ch. 11.10 - Why is the throttling valve not replaced by an...Ch. 11.10 - In a refrigeration system, would you recommend...Ch. 11.10 - Does the area enclosed by the cycle on a T-s...Ch. 11.10 - Consider two vapor-compression refrigeration...Ch. 11.10 - It is proposed to use water instead of...
Ch. 11.10 - The COP of vapor-compression refrigeration cycles...Ch. 11.10 - A 10-kW cooling load is to be served by operating...Ch. 11.10 - An ice-making machine operates on the ideal...Ch. 11.10 - An air conditioner using refrigerant-134a as the...Ch. 11.10 - An ideal vapor-compression refrigeration cycle...Ch. 11.10 - A refrigerator operates on the ideal...Ch. 11.10 - A refrigerator uses refrigerant-134a as the...Ch. 11.10 - An ideal vapor-compression refrigeration cycle...Ch. 11.10 - A refrigerator uses refrigerant-134a as its...Ch. 11.10 - A refrigerator uses refrigerant-134a as the...Ch. 11.10 - A commercial refrigerator with refrigerant-134a as...Ch. 11.10 - The manufacturer of an air conditioner claims a...Ch. 11.10 - Prob. 24PCh. 11.10 - How is the second-law efficiency of a refrigerator...Ch. 11.10 - Prob. 26PCh. 11.10 - Prob. 27PCh. 11.10 - Prob. 28PCh. 11.10 - Bananas are to be cooled from 28C to 12C at a rate...Ch. 11.10 - A vapor-compression refrigeration system absorbs...Ch. 11.10 - A room is kept at 5C by a vapor-compression...Ch. 11.10 - Prob. 32PCh. 11.10 - A refrigerator operating on the vapor-compression...Ch. 11.10 - When selecting a refrigerant for a certain...Ch. 11.10 - A refrigerant-134a refrigerator is to maintain the...Ch. 11.10 - Consider a refrigeration system using...Ch. 11.10 - A refrigerator that operates on the ideal...Ch. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - Do you think a heat pump system will be more...Ch. 11.10 - What is a water-source heat pump? How does the COP...Ch. 11.10 - A heat pump operates on the ideal...Ch. 11.10 - Refrigerant-134a enters the condenser of a...Ch. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - The liquid leaving the condenser of a 100,000...Ch. 11.10 - Reconsider Prob. 1144E. What is the effect on the...Ch. 11.10 - A heat pump using refrigerant-134a heats a house...Ch. 11.10 - A heat pump using refrigerant-134a as a...Ch. 11.10 - Reconsider Prob. 1148. What is the effect on the...Ch. 11.10 - Prob. 50PCh. 11.10 - How does the COP of a cascade refrigeration system...Ch. 11.10 - Consider a two-stage cascade refrigeration cycle...Ch. 11.10 - Can a vapor-compression refrigeration system with...Ch. 11.10 - Prob. 54PCh. 11.10 - A certain application requires maintaining the...Ch. 11.10 - Prob. 56PCh. 11.10 - Repeat Prob. 1156 for a flash chamber pressure of...Ch. 11.10 - Prob. 59PCh. 11.10 - A two-stage compression refrigeration system with...Ch. 11.10 - A two-stage compression refrigeration system with...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - Repeat Prob. 1163E if the 30 psia evaporator is to...Ch. 11.10 - Consider a two-stage cascade refrigeration cycle...Ch. 11.10 - How does the ideal gas refrigeration cycle differ...Ch. 11.10 - Prob. 67PCh. 11.10 - Devise a refrigeration cycle that works on the...Ch. 11.10 - How is the ideal gas refrigeration cycle modified...Ch. 11.10 - Prob. 70PCh. 11.10 - How do we achieve very low temperatures with gas...Ch. 11.10 - An ideal gas refrigeration system operates with...Ch. 11.10 - Air enters the compressor of an ideal gas...Ch. 11.10 - Repeat Prob. 1173 for a compressor isentropic...Ch. 11.10 - An ideal gas refrigeration cycle uses air as the...Ch. 11.10 - Rework Prob. 1176E when the compressor isentropic...Ch. 11.10 - A gas refrigeration cycle with a pressure ratio of...Ch. 11.10 - A gas refrigeration system using air as the...Ch. 11.10 - An ideal gas refrigeration system with two stages...Ch. 11.10 - Prob. 81PCh. 11.10 - Prob. 82PCh. 11.10 - What are the advantages and disadvantages of...Ch. 11.10 - Prob. 84PCh. 11.10 - Prob. 85PCh. 11.10 - Prob. 86PCh. 11.10 - Prob. 87PCh. 11.10 - Heat is supplied to an absorption refrigeration...Ch. 11.10 - An absorption refrigeration system that receives...Ch. 11.10 - An absorption refrigeration system receives heat...Ch. 11.10 - Heat is supplied to an absorption refrigeration...Ch. 11.10 - Prob. 92PCh. 11.10 - Prob. 93PCh. 11.10 - Consider a circular copper wire formed by...Ch. 11.10 - An iron wire and a constantan wire are formed into...Ch. 11.10 - Prob. 96PCh. 11.10 - Prob. 97PCh. 11.10 - Prob. 98PCh. 11.10 - Prob. 99PCh. 11.10 - Prob. 100PCh. 11.10 - Prob. 101PCh. 11.10 - Prob. 102PCh. 11.10 - A thermoelectric cooler has a COP of 0.18, and the...Ch. 11.10 - Prob. 104PCh. 11.10 - Prob. 105PCh. 11.10 - Prob. 106PCh. 11.10 - Rooms with floor areas of up to 15 m2 are cooled...Ch. 11.10 - Consider a steady-flow Carnot refrigeration cycle...Ch. 11.10 - Consider an ice-producing plant that operates on...Ch. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - A heat pump operates on the ideal...Ch. 11.10 - A large refrigeration plant is to be maintained at...Ch. 11.10 - Repeat Prob. 11112 assuming the compressor has an...Ch. 11.10 - An air conditioner with refrigerant-134a as the...Ch. 11.10 - A refrigerator using refrigerant-134a as the...Ch. 11.10 - Prob. 117RPCh. 11.10 - An air conditioner operates on the...Ch. 11.10 - Consider a two-stage compression refrigeration...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - The refrigeration system of Fig. P11122 is another...Ch. 11.10 - Repeat Prob. 11122 if the heat exchanger provides...Ch. 11.10 - An aircraft on the ground is to be cooled by a gas...Ch. 11.10 - Consider a regenerative gas refrigeration cycle...Ch. 11.10 - An ideal gas refrigeration system with three...Ch. 11.10 - Prob. 130RPCh. 11.10 - Derive a relation for the COP of the two-stage...Ch. 11.10 - Prob. 133FEPCh. 11.10 - Prob. 134FEPCh. 11.10 - Prob. 135FEPCh. 11.10 - Prob. 136FEPCh. 11.10 - Prob. 137FEPCh. 11.10 - An ideal vapor-compression refrigeration cycle...Ch. 11.10 - Prob. 139FEPCh. 11.10 - An ideal gas refrigeration cycle using air as the...Ch. 11.10 - Prob. 141FEPCh. 11.10 - Prob. 142FEP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Why is two-stage compression popular for extra-low-temperature refrigeration systems?arrow_forwardFour methods for controlling head pressure in an air-cooled condenser are ______, ______, _______, andarrow_forwardWelded ______sealed compressors are normally used in household refrigerators.arrow_forward
- Refrigerant 22 is the working fluid in a Carnot vapor refrigeration cycle for which the evaporator temperature is -30°C. Saturated vapor enters the condenser at 36°C, and saturated liquid exits at the same temperature. The mass flow rate of refrigerant is 10 kg/min. Determine the quality of refrigerant at inlet of compressor,arrow_forwardA vapor compression refrigeration systemhas an enthalpy of saturated liquid at the hightemperature side is 341.769 kJ/kg while at lowtemperature side is 131.27 kJ/kg and a latentheat of vaporization of 1312.63 kJ/kg. If themass flow rate of refrigerant is 0.50 kg/s.compute the tons of refrigeration.arrow_forwardA refrigeration system using refrigerant 12 is to have a refrigerating capacity of 80 kW. The cycle is a standard vapor-compression cycle in which the evaporating temperature is -15°C and the condensing temperature 30°C. At the entrance to the evaporator, what is the fraction of vapor in the mixture expressed on a mass basis? 0.97 0.29 0.92 0.27arrow_forward
- In a cooling machine that uses R-134a as a refrigerant and operates according to the ideal vapor compression refrigeration cycle, the cooled environment is kept at -30 °C and the condensation temperature entering the condenser at 18 °C with a flow rate of 0.25 kg/s and leaving the water at 26 °C. are given. The refrigerant enters the condenser at a pressure of 1.2 MPa and 65 °C and exits at 42 °C. The inlet condition of the compressor is 60 kPa and -34 ° C, and it gains 450 W of heat from the environment during the compression process. Accordingly, calculate (a) dryness fraction of the refrigerant in the evaporator inlet (b) the cooling capacity (c) the COP value of the cooling system.arrow_forwardAn ideal vapor compression cycle operates between the temperature limits of -5 °c and 30 °C and uses R134a as the refrigerant, which flows at a rate of 0.6 kg/s. The P-h- as well as T-s-diagrams that illustrate the refrigerating process is given in diagram, and respectively. Refigerant is compressed to the state in the compressor and heat is rejected in the condenser at constant for ideal Vapour compression cycle.arrow_forwardA plant using R134a refrigerant has a cooling capacity of 352 kW of refrigeration. It evaporates at 0 Cand condenses at 35 C, with the 5 of superheat at the evaporator outlet and 5 K of sub-cooling at the condenser outlet. Assuming isentropic compression and ignoring pressure drops in the piping, the evaporator and condenser, determi the following; a) The refrigeration effect b) The mass flow rate of refrigerant ) The compressor power d) The rate of heatrejection at the condenser e) The COP 0 The corresponding Carnot COP g) The percentage Carnot-efficiencyarrow_forward
- A refrigeration system operated on an ideal vapor-compression using R-12 with a vaporizing temperature of -10 degrees Celsius and a condensing temperature of 30 degrees Celsius, it requires 15 hp to drive the motor of the compressor. Find the ff: Enthalpies at each point of the cycle in kJ/kg Refrigerating Capacity in TOR • Mass of the Refrigerant in kg/s Percent Quality in the mixture Heat Rejected in kW Coefficient of Performance • Schematic and P-h Diagramarrow_forwardi need the answer quicklyarrow_forwardA Freon 12 vapour compression system operating at a condenser temperature of 45Co and an evaporator temperature of 0Co develops 20 tons of refrigeration. Using the p-h diagram for Freon 12, determine; (15) a) The mass flow rate of the refrigerant circulated. b) The heat rejected in the condenser, and c) The Carnot COP and the actual COP of the cycle.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY