The following data were obtained during gas-liquid chromatography of a mixture of two volatile constituents of a pesticide residue in cereal crops. Which of the following statements about the experiment is TRUE? Component Retention time (min) Peak width at base (min) 5.80 0.85 Y 6.75 0.75 There was overlap between the X and Y peaks. O The theoretical plate number is higher for component X than for component Y. O It is not possible to say for which component the HETP was lower because the column length is not stated. O Inclusion of an internal standard would have enabled quantitative analysis of the mixture. O The resolution for the two components exceeds 1.0.

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
The following data were obtained during gas-liquid chromatography of a mixture of two
volatile constituents of a pesticide residue in cereal crops.
Which of the following statements about the experiment is TRUE? *
Component
Retention time (min) Peak width at base (min)
5.80
0.85
Y
6.75
0.75
O There was overlap between the X and Y peaks.
O The theoretical plate number is higher for component X than for component Y.
It is not possible to say for which component the HETP was lower because the column length is not stated.
Inclusion of an internal standard would have enabled quantitative analysis of the mixture.
The resolution for the two components exceeds 1.0.
Transcribed Image Text:The following data were obtained during gas-liquid chromatography of a mixture of two volatile constituents of a pesticide residue in cereal crops. Which of the following statements about the experiment is TRUE? * Component Retention time (min) Peak width at base (min) 5.80 0.85 Y 6.75 0.75 O There was overlap between the X and Y peaks. O The theoretical plate number is higher for component X than for component Y. It is not possible to say for which component the HETP was lower because the column length is not stated. Inclusion of an internal standard would have enabled quantitative analysis of the mixture. The resolution for the two components exceeds 1.0.
Expert Solution
steps

Step by step

Solved in 7 steps with 3 images

Blurred answer
Knowledge Booster
Analytical Separations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY