QUESTION 5 In a chromatographic separation using a polar stationary phase and a mobile phase composed of 60% hexane and 40% ethyl acetate, two compounds, benzene (peak A) and toluene (peak B), are eluted. The width of peak A at its base is 1.2 min, the width of peak B at its base is 1.3 min, and the retention time of peak A is 5.2 min and peak B is 3.5 min. What is the resolution (Rs) between these two peaks and is it acceptable? R = 1.36. It is not an acceptable resolution. OR=0.74. It is an acceptable resolution. R=1.36. It is an acceptable resolution. R = 0.74. It is not an acceptable resolution.

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
QUESTION 5
In a chromatographic separation using a polar stationary phase and a
mobile phase composed of 60% hexane and 40% ethyl acetate, two
compounds, benzene (peak A) and toluene (peak B), are eluted. The width
of peak A at its base is 1.2 min, the width of peak B at its base is 1.3 min,
and the retention time of peak A is 5.2 min and peak B is 3.5 min.
What is the resolution (Rs) between these two peaks and is it acceptable?
R = 1.36. It is not an acceptable resolution.
R = 0.74. It is an acceptable resolution.
R = 1.36. It is an acceptable resolution.
R = 0.74. It is not an acceptable resolution.
Transcribed Image Text:QUESTION 5 In a chromatographic separation using a polar stationary phase and a mobile phase composed of 60% hexane and 40% ethyl acetate, two compounds, benzene (peak A) and toluene (peak B), are eluted. The width of peak A at its base is 1.2 min, the width of peak B at its base is 1.3 min, and the retention time of peak A is 5.2 min and peak B is 3.5 min. What is the resolution (Rs) between these two peaks and is it acceptable? R = 1.36. It is not an acceptable resolution. R = 0.74. It is an acceptable resolution. R = 1.36. It is an acceptable resolution. R = 0.74. It is not an acceptable resolution.
Expert Solution
steps

Step by step

Solved in 3 steps with 4 images

Blurred answer
Knowledge Booster
Analytical Separations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY