A generation station of 3 MW supply a two regions A & B .The line losses are neglected and the load variation of these regions is as follow: Region A (Time) 11 a.m From 11 a.m to 6 p.m No-load From midnight to From 5 a.m to From 8 a.m to Load (kw) 5 a.m No-load 8 a.m 1200 800 Region B (Time) From From midnight to 6 a.m to 3 p.m to 7 p.m to 6 a.m 3 p.m 7p.m 9 p.m Load (kw) 400 900 No-load 1800 From From From 6 p.m to midnight 600 From 9 p.m to midnight 200 1-Plot The daily load curve of the total system. 2-Find the load factor, diversity factor,plant user factor and the actual generation by the station in kwh in the day for the total system.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.7P: Let a 100V sinusoidal source be connected to a series combination of a 3 resistor, an 8 inductor,...
icon
Related questions
Question
A generation station of 3 MW supply a two regions A & B .The line
losses are neglected and the load variation of these regions is as follow:
Region A
(Time)
11 a.m
From
11 a.m to
6 p.m
No-load
From
midnight to
From
5 a.m to
From
8 a.m to
Load (kw)
5 a.m
No-load
8 a.m
1200
800
Region B
(Time)
From
From
midnight to
6 a.m to
3 p.m to
7 p.m to
6 a.m
3 p.m
7p.m
9 p.m
Load (kw)
400
900
No-load
1800
From
From
From
6 p.m to
midnight
600
From
9 p.m to
midnight
200
1-Plot The daily load curve of the total system.
2-Find the load factor, diversity factor,plant user factor and the actual
generation by the station in kwh in the day for the total system.
Transcribed Image Text:A generation station of 3 MW supply a two regions A & B .The line losses are neglected and the load variation of these regions is as follow: Region A (Time) 11 a.m From 11 a.m to 6 p.m No-load From midnight to From 5 a.m to From 8 a.m to Load (kw) 5 a.m No-load 8 a.m 1200 800 Region B (Time) From From midnight to 6 a.m to 3 p.m to 7 p.m to 6 a.m 3 p.m 7p.m 9 p.m Load (kw) 400 900 No-load 1800 From From From 6 p.m to midnight 600 From 9 p.m to midnight 200 1-Plot The daily load curve of the total system. 2-Find the load factor, diversity factor,plant user factor and the actual generation by the station in kwh in the day for the total system.
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning