17-Substances A and B have retention times of 3.20 and 5.40 min, respectively, on a 20 cm column. The peak widths (at base) for A and B are 0.80 and0.90 min, respectively. Calculate the column length that required to seperate substances A and B from each other when resolution of the column increased to 3.00 A) 26.88 cm BY 53.67 cm C) 17.80 cm D) 47.27 cm E) 37.15 cm O Req L= 41C-20. 20 H

Principles of Instrumental Analysis
7th Edition
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Chapter13: An Introduction To Ultraviolet-visible Molecular Absorption Spectrometry
Section: Chapter Questions
Problem 13.24QAP
icon
Related questions
Question
Don't used Ai solution
17-Substances A and B have retention times of 3.20 and 5.40
min, respectively, on a 20 cm column. The peak widths (at
base) for A and B are 0.80 and0.90 min, respectively.
Calculate the column length that required to seperate
substances A and B from each other when resolution of the
column increased to 3.00
A) 26.88 cm
BY 53.67 cm
C) 17.80 cm
D) 47.27 cm
E) 37.15 cm O
Req
L= 41C-20.
20
H
Transcribed Image Text:17-Substances A and B have retention times of 3.20 and 5.40 min, respectively, on a 20 cm column. The peak widths (at base) for A and B are 0.80 and0.90 min, respectively. Calculate the column length that required to seperate substances A and B from each other when resolution of the column increased to 3.00 A) 26.88 cm BY 53.67 cm C) 17.80 cm D) 47.27 cm E) 37.15 cm O Req L= 41C-20. 20 H
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage