Introduction To Health Physics
5th Edition
ISBN: 9780071835275
Author: Johnson, Thomas E. (thomas Edward), Cember, Herman.
Publisher: Mcgraw-hill Education,
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 9, Problem 9.29P
To determine
The sensitivity of a thermal neutron detector
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The linear attenuation coefficient for 2.0-MeV gamma rays in water is 4.9 m-1 and 52 m-1 in lead. What thickness of water would give the same shielding for gamma rays as 15 mm of lead?
The RDA for the trace element selenium is 0.000070 g>day. Express this dose in mg>day.
Calculate the prompt temperature coefficient of reactivity at temperature 25° C
of a reactor lattice consisting of an assembly of natural uranium (metallic) rods
with a diameter of 3.3 cm in a heavy water moderator, in which the moderator
volume to fuel volume ratio is 30.
Margin of error 1.5%.
aprompt -1.685672E-5 /K
=
Chapter 9 Solutions
Introduction To Health Physics
Ch. 9 - Prob. 9.1PCh. 9 - Prob. 9.2PCh. 9 - Prob. 9.3PCh. 9 - Prob. 9.4PCh. 9 - Prob. 9.5PCh. 9 - Prob. 9.6PCh. 9 - Prob. 9.7PCh. 9 - Prob. 9.8PCh. 9 - Prob. 9.9PCh. 9 - Prob. 9.10P
Ch. 9 - Prob. 9.11PCh. 9 - Prob. 9.12PCh. 9 - Prob. 9.13PCh. 9 - A counting system has a background of 360 counts...Ch. 9 - Prob. 9.15PCh. 9 - Prob. 9.16PCh. 9 - Prob. 9.17PCh. 9 - Prob. 9.18PCh. 9 - Prob. 9.19PCh. 9 - Prob. 9.20PCh. 9 - Prob. 9.21PCh. 9 - Prob. 9.22PCh. 9 - Prob. 9.23PCh. 9 - Prob. 9.24PCh. 9 - Prob. 9.25PCh. 9 - Prob. 9.26PCh. 9 - Prob. 9.27PCh. 9 - Prob. 9.28PCh. 9 - Prob. 9.29PCh. 9 - Prob. 9.31PCh. 9 - Prob. 9.33PCh. 9 - Prob. 9.34PCh. 9 - Prob. 9.35PCh. 9 - Prob. 9.38PCh. 9 - Prob. 9.39PCh. 9 - Prob. 9.44P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, physics and related others by exploring similar questions and additional content below.Similar questions
- The linear absorption coefficient for 5-MeV gamma rays in lead is 78 m-1. Find the thickness of lead required to reduce by one-fourth the intensity of beam of such gamma rays.arrow_forwardA radiographic technique calls for 46 kVp and 28 mAs which results in an exposure of 278 µGy. What is the expected exposure if the technique is changed to 75 kVp and 14 mAs? Round your answer to the nearest whole number. Do not include units.arrow_forwardA beam of 5.0 MeV alpha particles (q-2e) has a cross-sectional area of 1.50 cm2. It is incident on flesh (p-950 kg/m³) and penetrates to a depth of 0.70 mm. a) What dose in Gy does the beam provide to the flesh in a time of 3.0 s? b) What effective dose does it provide? Assume the beam to carry a current of 2.50 x 109 A and to have QF - 14.arrow_forward
- Control rods are usually made of an alloy of indium. The absorption cross-section of indium for thermal neutron is 71 b, and the mass density of solid indium is 7.31 g cm-3. Estimate the neutron transmission ratio of a 1-cm thick indium slab. (a) 0.07 (b)0.7 (c) 0.01 (d) 0.1arrow_forwardA radioactive source is producing 1.50 MeV gamma rays. If two detectors are placed 4.00 m and 7.00 m away respectively, what is the ratio of the measured intensities of the near detector over the far detector (I2/I1)? Do NOT include units in your answer answer to 2 decimal places.arrow_forward. A Geiger counter measures background radiation and records 950 counts in 10 minutes. Then the Geiger counter is brought near a radioactive source and it records 1430 counts in 10 minutes. Compute R,, the rate (in counts/min) due to the source only. Also compute &R,, the uncertainty in the rate due to the source only . Suppose in this experiment, the penetration depth in lead is 9.4 mm (whicharrow_forward
- (a) A student wishes to measure the half-life of a radioactive substance using a small sample. Consecutive clicks of her radiation counter are randomly spaced in time. The counter registers 372 counts during one 5.00-min interval and 337 counts during the next 5.00 min. The average background rate is 15 counts per minute. Find the most probable value for the half-life. (b) Express the estimated half-life with an appropriate estimated uncertainty.arrow_forwardA radioactive contaminant gives an unfortunate 0.5 kg lab rat a dose of 1500 rem in just 1 minute. Assuming that the half life of the radioactive isotope in the contaminant is much longer than1 minute, what would the activity (in Bq) of the contaminant be if the contaminant is a 1.1MeV beta emitter?arrow_forwardA small 10-gram source of cobalt-60 is in a vacuum. (a) What is the activity of the cobalt-60source in Bq? (b) What is the actual gamma-ray flux in cm2-s-1 at a point of measurement500 cm from the source due to the cobalt-60 emitted gamma-rays? (c) If the backgroundgamma-ray flux in the vicinity of the 10-g source is 7.8×107cm-2-s-1, what is the totalgamma-ray flux at the point of measurement, including the background? (d) What thicknessof a lead shield in cm would have to be placed between the source and the point ofmeasurement to reduce the total of the background plus the uncollided gamma-ray flux fromthe cobalt-60 source to 1.00×108cm-2-s-1 at that point? (I've attempted part a of the problem and don't know how to continue)arrow_forward
- A particular radioactive source produces 100 mrad of 2-MeV gamma rays per hour at a distance of 1.0 m. (a) How long could a person stand at this distance before accumulating an intolerable dose of 1 rem? (b) Assuming the gamma radiation is emitted uniformly in all directions, at what distance would a person recieve a dose of 10 mrad/h from this source? dont provode hand written solutionarrow_forwardPlease provide Handwritten answer. Two 13.3 mg radium tubes are arranged in a line with their centers 5.5 cm apart. A weaker source is placed midway between them. How much radium should be in this latter source to produce the same dose rates to points opposite each of the sources at a distance of 2.0 cm away from the line. Assume sources 1.35 cm active length 1.0 mm Pt.arrow_forward✓ ON "O 2.75 MeV 0.511 MeV 0.511 MeV B, E= 1.73 MeV Eave = 0.721 Mev O MeVarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- College PhysicsPhysicsISBN:9781938168000Author:Paul Peter Urone, Roger HinrichsPublisher:OpenStax College
College Physics
Physics
ISBN:9781938168000
Author:Paul Peter Urone, Roger Hinrichs
Publisher:OpenStax College