18.6
An
is
5x10 3
behind
shield
block
with
ray
orifice
of
source
m
a
an
chamber 0.1 m from the shield
reads 150 cpm. If the diameter of the detector is 0.05 m, what
10 3
radius.
An
ion
block
should be the correct reading?
Answer:
212.6 срт.
A radiographic technique calls for 46 kVp and 28 mAs which results in an exposure of 278 µGy. What is the expected exposure
if the technique is changed to 75 kVp and 14 mAs? Round your answer to the nearest whole number. Do not include units.
A radioactive source is producing 1.50 MeV gamma rays. If two detectors are placed 4.00 m and 7.00 m away respectively, what is the ratio of the measured intensities of the near detector over the far detector (I2/I1)? Do NOT include units in your answer answer to 2 decimal places.
Chapter 9 Solutions
Introduction To Health Physics
Ch. 9 - Prob. 9.1PCh. 9 - Prob. 9.2PCh. 9 - Prob. 9.3PCh. 9 - Prob. 9.4PCh. 9 - Prob. 9.5PCh. 9 - Prob. 9.6PCh. 9 - Prob. 9.7PCh. 9 - Prob. 9.8PCh. 9 - Prob. 9.9PCh. 9 - Prob. 9.10P
Ch. 9 - Prob. 9.11PCh. 9 - Prob. 9.12PCh. 9 - Prob. 9.13PCh. 9 - A counting system has a background of 360 counts...Ch. 9 - Prob. 9.15PCh. 9 - Prob. 9.16PCh. 9 - Prob. 9.17PCh. 9 - Prob. 9.18PCh. 9 - Prob. 9.19PCh. 9 - Prob. 9.20PCh. 9 - Prob. 9.21PCh. 9 - Prob. 9.22PCh. 9 - Prob. 9.23PCh. 9 - Prob. 9.24PCh. 9 - Prob. 9.25PCh. 9 - Prob. 9.26PCh. 9 - Prob. 9.27PCh. 9 - Prob. 9.28PCh. 9 - Prob. 9.29PCh. 9 - Prob. 9.31PCh. 9 - Prob. 9.33PCh. 9 - Prob. 9.34PCh. 9 - Prob. 9.35PCh. 9 - Prob. 9.38PCh. 9 - Prob. 9.39PCh. 9 - Prob. 9.44P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, physics and related others by exploring similar questions and additional content below.Similar questions
- the mass m, is given the equation m=i[0.69]t. i is the intitial dose and t is the number of hours since the dose. Suppose the patient is given inital dose of 200mg. When will the amount of ibuprofen in the bloodstream be reduced by a factor of one half. round your answer to the nearest tenth of an hourarrow_forwardA radioactive sample is analyzed to give a total of 4000 counts; background gives 250. How many counts were detected with one standard deviation?arrow_forwardQuestion 1. There are four factors: A, B, C, D. We assume that each replicate was considered as a block. Fill in the table as below and analyze the experiment with conclusions. Using a = 0.05. Treatment combination Rep 1 Rep 2 7.786 | 7.377014 6.789 | 6.398278 5.834 5.554411 A C D -1 a - b 2.341 2.28354 6.133 5.702366 3.669 | 3.608621 d ab ас 6.154 5.87312 ad 5.819| 5.550515 bc 12.887 12.62869 2.753 2.261361 4.451 4.411148 0.873 | 0.793026 4.678 | 4.259536 3.728 3.695787 bd cd abc abd bcd аcd 10.478 10.33168 abcd 1.722 | 1.365419 Table 1arrow_forward
- A Geiger counter measures 750 counts in 5.0 min. How long would you want to count to get a relative error of 1%?arrow_forwardA worker will need to conduct a repair to a pipe containing radioactive waste. The pipe is 10 m long, and the worker will need to be standing 50 cm from the pipe. A remote detector was used to take a reading of 1.5 R/hr at 3 m from the pipe. a) What is the dose rate at the work position? b) If the worker's dose limit is 30 rad, how long will he have to complete the work? Assume that there is no dose from approaching and leaving the work location.arrow_forward4arrow_forward
- A laboratory blood test is 99% effective in detecting a certain disease, when it is in fact present. However, the test also yields a false positive result for 0.5% of the healthy person tested (that is, if a healthy person is tested, then, with probability 0.005, the test will imply he has the disease). If 0.1 percent of the population actually has the disease, what is the probability that a person has the disease given that his test result is positive?arrow_forwardThe mass of an aluminum cube was measured to be (A)=71.2 g. Using the Vernier caliper, the length of its side has measurements between 29 mm and 30 mm in the main scale and falls exactly at the (B)=28 mark on Vernier scale. From this data, what is the percent error between the standard and experimental density of aluminum in (F)? Density of Solids Side Length Measurement Density (N) Volume Percent Material Mass (g) Number of Tick Marks Final Reading (cm³) Standard Experimental Error (%) Main Scale Vernier Scale (mm) Aluminum (A) 29 and 30 (B) (C) (D) 2.70 (E) (F) O 5.052% 2.095% 7.603% O 3.348%arrow_forwardA beam of 5.0 MeV alpha particles (q-2e) has a cross-sectional area of 1.50 cm2. It is incident on flesh (p-950 kg/m³) and penetrates to a depth of 0.70 mm. a) What dose in Gy does the beam provide to the flesh in a time of 3.0 s? b) What effective dose does it provide? Assume the beam to carry a current of 2.50 x 109 A and to have QF - 14.arrow_forward
- The rate of a simple enzyme reaction is given by the standard Michaelis–Menten equation: rate = Vmax [s]/([s] + KM) if the Vmax of an enzyme is 100 μmole/sec and the KM is 1 mM, at what substrate concentration is the rate 50 μmole/sec? Plot a graph of rate versus substrate (s) concentration for [s] = 0 to 10 mM. Convert this to a plot of 1/rate versus 1/[s]. Why is the latter plot a straight line?arrow_forwardDo not copyarrow_forwardIn a Measurement ,the Expected value is 48 V and the measured value is 43 V. Find (i) Absolute error Ea , (ii)Relative error Er, (iii) Absolute accuracy Aa (iv) Relative Accuracy Ar.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- College PhysicsPhysicsISBN:9781305952300Author:Raymond A. Serway, Chris VuillePublisher:Cengage LearningUniversity Physics (14th Edition)PhysicsISBN:9780133969290Author:Hugh D. Young, Roger A. FreedmanPublisher:PEARSONIntroduction To Quantum MechanicsPhysicsISBN:9781107189638Author:Griffiths, David J., Schroeter, Darrell F.Publisher:Cambridge University Press
- Physics for Scientists and EngineersPhysicsISBN:9781337553278Author:Raymond A. Serway, John W. JewettPublisher:Cengage LearningLecture- Tutorials for Introductory AstronomyPhysicsISBN:9780321820464Author:Edward E. Prather, Tim P. Slater, Jeff P. Adams, Gina BrissendenPublisher:Addison-WesleyCollege Physics: A Strategic Approach (4th Editio...PhysicsISBN:9780134609034Author:Randall D. Knight (Professor Emeritus), Brian Jones, Stuart FieldPublisher:PEARSON
College Physics
Physics
ISBN:9781305952300
Author:Raymond A. Serway, Chris Vuille
Publisher:Cengage Learning
University Physics (14th Edition)
Physics
ISBN:9780133969290
Author:Hugh D. Young, Roger A. Freedman
Publisher:PEARSON
Introduction To Quantum Mechanics
Physics
ISBN:9781107189638
Author:Griffiths, David J., Schroeter, Darrell F.
Publisher:Cambridge University Press
Physics for Scientists and Engineers
Physics
ISBN:9781337553278
Author:Raymond A. Serway, John W. Jewett
Publisher:Cengage Learning
Lecture- Tutorials for Introductory Astronomy
Physics
ISBN:9780321820464
Author:Edward E. Prather, Tim P. Slater, Jeff P. Adams, Gina Brissenden
Publisher:Addison-Wesley
College Physics: A Strategic Approach (4th Editio...
Physics
ISBN:9780134609034
Author:Randall D. Knight (Professor Emeritus), Brian Jones, Stuart Field
Publisher:PEARSON