Chapter 9, Problem 9.11QAP
Interpretation Introduction
Interpretation:
A grating monochromator has the wavelength of 500 nm with line width of 0.002 nm. For the first order grating, which is ruled at 2400 grooves/mm Minimum theoretical size of grating needs to be calculated.
Concept introduction:
Minimum theoretical size grating monochromator will be calculated by using the formula of resolving power, which is given as-
Here,
λ =wavelength
Δλ = wavelength difference
n = diffraction order
N = total number of slits
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
How would the position of a spectral line change as the separation d between the lines of the grating is increased?
7 of 10
>
Atomic absorption spectroscopy was used to determine the amount of aluminum in a sample of sunscreen. A blank solution was
measured seven times to determine the detection and quantitation limits of the spectrometer. The blank readings were: 0.0073,
0.0082, 0.0110, 0.0101, 0.0102, 0.0098, and 0.0090 AU. Determine the signal at the detection limit and the signal at the limit of
quantitation for this method.
signal detection limit:
signal limit of quantitation:
hulu
étv
14
Express a wavelength of 442 nm as (a) a frequency. (b) a wavenumber.
Chapter 9 Solutions
Principles of Instrumental Analysis
Ch. 9 - Prob. 9.1QAPCh. 9 - Prob. 9.2QAPCh. 9 - Why is an electrothermal atomizer more sensitive...Ch. 9 - Prob. 9.4QAPCh. 9 - Prob. 9.5QAPCh. 9 - Prob. 9.6QAPCh. 9 - Prob. 9.7QAPCh. 9 - Prob. 9.8QAPCh. 9 - Prob. 9.9QAPCh. 9 - Prob. 9.10QAP
Ch. 9 - Prob. 9.11QAPCh. 9 - Prob. 9.12QAPCh. 9 - Prob. 9.13QAPCh. 9 - Prob. 9.14QAPCh. 9 - Prob. 9.15QAPCh. 9 - Prob. 9.16QAPCh. 9 - Prob. 9.17QAPCh. 9 - In the concentration range of 1 to 100 g/mL P,...Ch. 9 - Prob. 9.19QAPCh. 9 - Prob. 9.20QAPCh. 9 - Prob. 9.21QAPCh. 9 - The chromium in an aqueous sample was determined...Ch. 9 - Prob. 9.23QAP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- Use the data in Figure 4.8 to estimate the ratio of radiation intensity at 10,000 Å (infrared) to that at 5000 Å (visible) from a blackbody at 5000 K. How will this ratio change with increasing temperature? Explain how this change occurs.arrow_forwardThe full width at half maximum of an atomic absorption line at 589 nm is 100 MHz. A beam of light passes through a gas with an atomic density of 10^17/m3 . Calculate: (1) The peak absorption coefficient due to this absorption line. You can assume that the index of refraction is close to 1 in for this dilute gas. (2) The frequency at which the resonant contribution to the refractive index is at a maximum. (3) The peak value of this resonant contribution to the index of refraction.arrow_forwardInductively coupled plasma-optical emission spectroscopy (ICP-OES) is a quantitative method for determining trace elements in liquid samples. ICP-OES and other methods of spectrochemical analysis are typically subject to errors due to the present of interferences. It had been reported that ICP-OES is significantly affected by spectral interference, but relatively less affected by the chemical interferences. (i) Explain why ICP-OES is significantly affected by spectral interference but less affected by chemical interferences.arrow_forward
- Which of the following statement is incorrect? The quality of grating of the monochromator affects the resolution of two closely spaced wavelengths in a spectrum. OICP (Inductively coupled plasma) is commonly used in atomic emission spectrometry. Cuvette is generally used for atomic absorption spectrometry (AAS) as the sample cell. The measurement in fluorescence spectrometry is generally more sensitive than absorption spectrometry.arrow_forwardAn aqueous solution of triphosphate derivative of molar mass 502 g per mol was prepared by dissolving 17.2 mg in enough water to make 500 cubic cm of solution and a sample was transferred to a cell of length 1 cm. The absorbance was measured as 1.011. Calculate the molar absorbance coefficient and the transmittance for a solution twice the concentration.arrow_forwardThienothiophene and sexithiophene are conjugated molecules used in printed organic electronics. A chlorobenzene solution of equal concentrations of the two molecules was prepared and its absorbance was recorded with a 0.01 cm sample cell to give 0.88 % transmittance (T) at 400 nm. Calculate the concentration of each of the molecules given that the molar absorption coefficient of the thienothiophene is 23,000 L.mol-1cm-1 and the sexithiophene is 34,000 L.mol-1cm-1. Remember that absorbance is additive.arrow_forward
- Suppose a student is preparing a set of standard solutions for use in a spectrophotometric study. If percent transmittance, %T, were measured in the standard solutions before the color had a chance to fully develop, the measured value would be compared with solutions that have allowed the color to fully develop.arrow_forwardThe quantum yield of light-induced chemical reactions (called photochemical reactions) measures the efficiency of the process. The quantum yield, ϕ, is defined as:ϕ=numberofreactioneventsnumberofphotonsabsorbed . Suppose a quantum yield for the reaction CH3X→CH3+Xis ϕ= 0.95. A cuvette containing a solution of CH3Xis irradiated with 280-nmwith a power of 885 mWfor 10.0 minutes. Part A Assuming total absorption of the light by the sample, what is the maximum amount (in moles) of CH3Xthat breaks apart?Express your answer to two significant figures. nothingmolCH3Xm o l C H 3 X actualarrow_forwardA solution sample, in a 0.50 cm cuvette, exhibits an absorbance of A = 0.84 at lamdamax= 230 nm. Calculate the concentration of the solution if the molar absorption coefficient of the compound at 230 nm is 14 mol–1 dm3 cm–1.arrow_forward
- What is the purpose of a matrix modifier in atomic spectroscopy?arrow_forwardd) Doppler broadening is a source of line broadening in the flame of an atomic absorption instrument, λ = 20 (7x10-7)(0.5. Find the Doppler line width for the absorption line λ = 248.3 nm of Fe in a 2500 K flame (T), where M is the mass of the atom (56 Da).arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningPrinciples of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage Learning
- Chemistry for Engineering StudentsChemistryISBN:9781285199023Author:Lawrence S. Brown, Tom HolmePublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning
Chemistry for Engineering Students
Chemistry
ISBN:9781285199023
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning