Question
Chapter 9, Problem 9.9QAP
Interpretation Introduction
Interpretation:
The reason for atomic emission to be more sensitive to flame instability than atomic absorption or fluorescence needs to be explained.
Concept introduction:
Spectral lines help in identifying the atoms and molecules. These are a result of absorption or emission of light in a comparatively narrower frequency range as compared to the frequencies nearby.
Fluorescence is the process by which a substance absorbing
In a defined space, the amount of a substance gives its concentration. A capacity of substance to absorb specific
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Why is fluorescence generally more sensitive than absorption measurements?
True or False: Emission spectroscopy can be used toidentify the components of paint’s pigments
The levels of Vitamin B1 in a sample of milk was determined using the Standard
Addition method and technique of fluorescence spectroscopy.
18.0 ml of the milk sample was diluted to 20.0 ml using distilled water and then the
fluorescence was measured. The resulting signal was 210 units.
A spike was made by taking 18.0 ml of the same milk sample, adding 1.0 ml of a 6.0
ppm Vitamin B1 standard solution, and then diluting to 20.0 ml using distilled
water. The signal of the spiked milk was 540 units.
Calculate the concentration of Vitamin B1 in the original milk sample (in ppm).
Report to 3 decimal places.
Chapter 9 Solutions
Principles of Instrumental Analysis
Ch. 9 - Prob. 9.1QAPCh. 9 - Prob. 9.2QAPCh. 9 - Why is an electrothermal atomizer more sensitive...Ch. 9 - Prob. 9.4QAPCh. 9 - Prob. 9.5QAPCh. 9 - Prob. 9.6QAPCh. 9 - Prob. 9.7QAPCh. 9 - Prob. 9.8QAPCh. 9 - Prob. 9.9QAPCh. 9 - Prob. 9.10QAP
Ch. 9 - Prob. 9.11QAPCh. 9 - Prob. 9.12QAPCh. 9 - Prob. 9.13QAPCh. 9 - Prob. 9.14QAPCh. 9 - Prob. 9.15QAPCh. 9 - Prob. 9.16QAPCh. 9 - Prob. 9.17QAPCh. 9 - In the concentration range of 1 to 100 g/mL P,...Ch. 9 - Prob. 9.19QAPCh. 9 - Prob. 9.20QAPCh. 9 - Prob. 9.21QAPCh. 9 - The chromium in an aqueous sample was determined...Ch. 9 - Prob. 9.23QAP
Knowledge Booster
Similar questions
- Describe the differences and similarities between spontaneous and stimulated emission.arrow_forwardCalculate the mass and linear absorption coefficients of air for CrKα radiation. Assume that air contains 80 % N2 and 20 % O2 by weight and has a density of 1.29 x10-3g/cm3?arrow_forward3. A solution of [FeSCN]2 is found to have 37.4 % transmission at 447 nm. If the molar absorption coefficient (e) is 4400 at Amax 447 nm, what is the concentration of [FeSCN]2 in the solution?arrow_forward
- Atomic fluorescence spectrometry is an attractive alternative to atomic absorption spectrometry for certain elements. For which elements is it best suited? Why?arrow_forwardIdentify and provide an explanation of the operational principles behind an Atomic Absorption Spectrometer.arrow_forwardAnalytical Chemistry II Compare between the advantages and disadvantages of atomic emission spectroscopy based on arcs and plasma.arrow_forward
- 26. What exactly is flame atomic absorbtion spectrometer?arrow_forward5. Show that 'H nuclei with large chemical shifts relative to TMS have small shielding constants.arrow_forward2. The content of sodium in a cooking salt substitute for a low-sodium diet can be determined by atomic emission spectroscopy using the addition standard calibration method. 10.07 g of sample are weighted and solved in 10 mL 1M HCI and 100 ml of water. This solution is transferred to a 250.0 mL volumetric flask and water is added to the mark. Calibration standards are prepared adding to 5 different 50.0 ml volumetric flasks, 25.0 ml of the sample solution, and 0, 1, 3, 5, and 8 ml respectively of a standard sodium solution. The standard sodium solution has been prepared by dilution up to 100.0 mL of 20.0 ml of another solution that contains 0.2501 g Nacl in 1.0 L of water. Instrumental responses are the following ones: Volume of sodium 1.0 3.0 5.0 8.0 standard (mL) Response (a.u.) 1.79 2.63 3.54 4.81 6.18 Provide the concentration of sodium in the cooking substitute expressed in mg Kg!.arrow_forward
- Which of the following statements concerning spectroscopy is correct? A) Concentration of a solution is directly proportional to the % of photons transmitted. B) Salt plates are often used in IR spectroscopic measurements because they are transparent in that region. C) Molar absorptivity is a constant for given species, regardless of concentration or wavelength. D) Fluorescence excitation is usually red-shifted from emission wavelength. E) 2 or more statements are correct. The absorbed energy to enable vibrational level transition falls within which wavelength range A) radio wave B) microwave C) IR D) X-ray E) UV and visiblearrow_forwardstate the relationship between absorbance and transmittancearrow_forwardSuppose you are analyzing mercury ions (Hg2+) in drinking water samples with atomic absorption spectroscopy. If the Hg2+ signal varies by a matrix of sample, which of the following should be used as a standard for calibration? Either cations or anions can be used if they are different from Hg2+, 0 H20 Any anions can be used if they are different from Hg2+ Any cations can be used if they are different from Hg?". Hg2+arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningPhysical ChemistryChemistryISBN:9781133958437Author:Ball, David W. (david Warren), BAER, TomasPublisher:Wadsworth Cengage Learning,
- Principles of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781337398909Author:Lawrence S. Brown, Tom HolmePublisher:Cengage LearningOrganic ChemistryChemistryISBN:9781305580350Author:William H. Brown, Brent L. Iverson, Eric Anslyn, Christopher S. FootePublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Physical Chemistry
Chemistry
ISBN:9781133958437
Author:Ball, David W. (david Warren), BAER, Tomas
Publisher:Wadsworth Cengage Learning,
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning
Chemistry for Engineering Students
Chemistry
ISBN:9781337398909
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning
Organic Chemistry
Chemistry
ISBN:9781305580350
Author:William H. Brown, Brent L. Iverson, Eric Anslyn, Christopher S. Foote
Publisher:Cengage Learning