Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 8, Problem 8.5QAP
Interpretation Introduction
Interpretation:
The reason for greater emission intensity of sodium lines at 589 and 589.6 nm for a solution containing KCl in comparison to the solution in which KCl is absent should be determined.
Concept introduction:
Spectral lines are lines which help in identifying the atoms and molecules. These are a result of absorption or emission of light in a comparatively narrower frequency range compared to the frequencies nearby.
Sodium spectrum has bright doublet at 588.995 and 589.592 nm. This is said to be sodium D-lines. The intensity of the line at 589 nanometers is twice that of the intensity of the line at 589.6 nanometers.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
2.
The content of sodium in a cooking salt substitute for a low-sodium diet can be
determined by atomic emission spectroscopy using the addition standard calibration method.
10.07 g of sample are weighted and solved in 10 mL 1M HCI and 100 ml of water. This solution
is transferred to a 250.0 mL volumetric flask and water is added to the mark.
Calibration standards are prepared adding to 5 different 50.0 ml volumetric flasks, 25.0 ml of
the sample solution, and 0, 1, 3, 5, and 8 ml respectively of a standard sodium solution. The
standard sodium solution has been prepared by dilution up to 100.0 mL of 20.0 ml of another
solution that contains 0.2501 g Nacl in 1.0 L of water.
Instrumental responses are the following ones:
Volume
of
sodium
1.0
3.0
5.0
8.0
standard (mL)
Response (a.u.)
1.79
2.63
3.54
4.81
6.18
Provide the concentration of sodium in the cooking substitute expressed in mg Kg!.
Describe the formation of
(i.) line emission spectra,
(ii.) line absorption spectra.
You have been asked to determine which heavy metals, if any are in a sample of sewage sludge. Why is atomic absorption spectroscopy not a good technique for the job and why is ICP- atomic emission spectroscopy a better choice?
Chapter 8 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Similar questions
- In high-temperature sources, sodium atoms emit a doublet with an average wavelength of 1139 nm. The transition responsible is from the 4s to 3p state. Set up a spreadsheet to calculate the ratio of the numberof excited atoms in the 4s state to the number in the ground 3s state over the temperature range from anacetylene-oxygen flame (3000°C) to the hottest part of an inductively coupled plasma source (8750°C).arrow_forwardCalculate the energy per mole of photons for the laser used in Blu-ray players ( = 405 nm)arrow_forwardWhen rubidium ions are heated to a high temperature, two lines are observed in its line spectrum at wavelengths (a) 7.9107 m and (b) 402107 m. What are the frequencies of the two lines? What color do we see when we heat a rubidium compound?arrow_forward
- The emission line used for zinc determinations in atomic emission spectroscopy is 214 nvm. If there are 1.50x10^10 atoms to achieve emitting light in the instrument flame at any given instant, what energy must the flame continuously supply to achieve this level of emission?arrow_forwardPlease don't provide handwritten solution ...arrow_forwardFood dye spectroscopy 2. At what wavelengths should the readings be taken? What instrumentation will you utilize with a solution of a known dye to determine the wavelength for your analysis?arrow_forward
- i) Discuss the differences between the AES and XPS in terms of principle and information obtained from the spectra.arrow_forwardThe average velocity of the atoms emitting a photon at 676 nm was 3184 m/s. What is the contribution to the peak width observed due to Doppler broadening under these conditions? Please express your answer in nm and use c = 299792458.0 m/s and h = 6.62607015e-34 m^2*kg/s for your calculations. Be wary of rounded numbers on your calculator!arrow_forwardAtomic absorption spectrophotometry is a method for the quantitative determination of metal ions. a) Describe in detail the AAS instrument and especially the parts that differ from a normal spectrophotometer. b) What light source is used in this technology and how does it work? c) What interferences can occur with this equipment? d) What is the theoretical basis of the AAS method?arrow_forward
- Give typed full explanation not a single word hand written otherwise leave it Which of the following statements are 'correct' regarding the fluorescence and phosphorescence emission processes commonly used in spectroscopy? I- Fluorescence and phosphorescence events are important emission processes that occur after the excitation of atoms or molecules with a thermal or chemical energy. II. In the photoluminescence processes called fluorescence and phosphorescence, a ray-excited species returns to its ground state by releasing its extra energy in the form of photons. III-If gaseous atoms are excited with any energy, the atom emits a beam with the wavelength that characterizes it, and makes fluorescent radiation. IV. It is possible for a light-excited atom or molecule to return to a lower energy level or ground state by heat transfer by collisions without emitting any rays. A. IandIII B. IandII C. II and IV D. Il and IIIarrow_forwardHow many photons are produced in a laser pulse of 0.347 J at 447 nm?arrow_forwardAtomic spectroscopy is a type of spectroscopic technique that is used for both quantitative and qualitative analysis of an element present in a sample. The atomic absorption lines are very narrow and the line emitted by the radiation source must be the same as the element to be analyzed. (i) (ii) Name two types of line sources that are commonly used in atomic absorption spectroscopy. Suggest two elements that can be determined by each type of the line sources as mentioned in part (a)(i) above.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Physical ChemistryChemistryISBN:9781133958437Author:Ball, David W. (david Warren), BAER, TomasPublisher:Wadsworth Cengage Learning,Chemistry & Chemical ReactivityChemistryISBN:9781337399074Author:John C. Kotz, Paul M. Treichel, John Townsend, David TreichelPublisher:Cengage Learning
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningPrinciples of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage LearningChemistry by OpenStax (2015-05-04)ChemistryISBN:9781938168390Author:Klaus Theopold, Richard H Langley, Paul Flowers, William R. Robinson, Mark BlaserPublisher:OpenStax
Physical Chemistry
Chemistry
ISBN:9781133958437
Author:Ball, David W. (david Warren), BAER, Tomas
Publisher:Wadsworth Cengage Learning,
Chemistry & Chemical Reactivity
Chemistry
ISBN:9781337399074
Author:John C. Kotz, Paul M. Treichel, John Townsend, David Treichel
Publisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning
Chemistry by OpenStax (2015-05-04)
Chemistry
ISBN:9781938168390
Author:Klaus Theopold, Richard H Langley, Paul Flowers, William R. Robinson, Mark Blaser
Publisher:OpenStax