Chapter 6, Problem 6.24P
(a)
To determine
The dose rate on contact with the 5-mm thick glass vial.
(b)
To determine
The dose rate at 2 m from the
(c)
To determine
The dose commitment from the 8-hour exposure.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A mouse has a thickness of approximately 20mm. Assume the mouse is completely composed of the ICRU4 tissue material that has a density of 1g/cm3. At 20keV, the mouse received a skin entry or surface dose of 5mGy. What would be
the number of photons per cm2 incident on the mouse?
the total dose that the tissue receives through the entire 20mm thickness.
the skin or surface dose at the exit of the animal?
Note the ICRU4 :
can you explain the question pls
A drug containing 9943Tc ( t1/2 = 6.05 h) is to be injected into a patient at 10:00 am. You are to prepare the sample 3.00 hours before the injection (at 7:00 am) with an activity of 3.53 μCi at the preparation time (7:00 am). What will be the activity of the sample at the time of the injection?A. 1.50 μCiB. 2.00 μCiC. 2.50 μCiD. 3.00 μCiE. 3.50 μCi
Chapter 6 Solutions
Introduction To Health Physics
Ch. 6 - A 50-µC/kg (approximately 200 mR) pocket dosimeter...Ch. 6 - Prob. 6.2PCh. 6 - Prob. 6.3PCh. 6 - Prob. 6.4PCh. 6 - Prob. 6.5PCh. 6 - Prob. 6.6PCh. 6 - Prob. 6.7PCh. 6 - Prob. 6.8PCh. 6 - Prob. 6.9PCh. 6 - Prob. 6.10P
Ch. 6 - Prob. 6.11PCh. 6 - Prob. 6.12PCh. 6 - Prob. 6.13PCh. 6 - Prob. 6.14PCh. 6 - Prob. 6.15PCh. 6 - Prob. 6.16PCh. 6 - Prob. 6.17PCh. 6 - Prob. 6.19PCh. 6 - Prob. 6.20PCh. 6 - Calculate the average power density, in watts per...Ch. 6 - Prob. 6.22PCh. 6 - Prob. 6.23PCh. 6 - Prob. 6.24PCh. 6 - Prob. 6.26PCh. 6 - Prob. 6.27PCh. 6 - Prob. 6.28PCh. 6 - Prob. 6.29PCh. 6 - Prob. 6.33P
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, physics and related others by exploring similar questions and additional content below.Similar questions
- question 4 pleasearrow_forward✓ ON "O 2.75 MeV 0.511 MeV 0.511 MeV B, E= 1.73 MeV Eave = 0.721 Mev O MeVarrow_forwardThe linear attenuation coefficient for 2.0-MeV gamma rays in water is 4.9 m-1 and 52 m-1 in lead. What thickness of water would give the same shielding for gamma rays as 15 mm of lead?arrow_forward
- Consider the region close to a nuclear reactor that produces large fluxes of prompt gamma rays with energies of about 7 MeV. Use the graph below, showing the mass attenuation coefficient of gamma rays in different stopping media as a function of energy, to determine the approximate thickness of lead shielding which would be required to reduce the gamma flux by a factor of 101º. The density of lead is 11.3 g cm. 10 5 Pb 0.5 0.1 Pb 0.05 Cu AL 0.01 0.01 0.05 0.1 0.5 1 5 10 50 100 Energy (MeV) Attenuation coefficient (cm²g")arrow_forwardThe maximum permissible workday dose for occupational exposure to radiation is 26 mrem. A 55-kg laboratory technician absorbs 3.3 mJ of 0.40-MeV gamma rays in a workday. The relative biological efficiency (RBE) for gamma rays is 1.00. What is the ratio of the equivalent dosage received by the technician to the maximum permissible equivalent dosage? O 0.23 0.28 O 0.30 0.25arrow_forwardQ7arrow_forward
- A particular radioactive source produces 100 mrad of 2-MeV gamma rays per hour at a distance of 1.0 m. (a) How long could a person stand at this distance before accumulating an intolerable dose of 1 rem? (b) Assuming the gamma radiation is emitted uniformly in all directions, at what distance would a person recieve a dose of 10 mrad/h from this source? dont provode hand written solutionarrow_forwardQ1arrow_forwardWhat is the range of a beta-interrupted IMEV particle in aluminum Adha whose ejection channel is 2.698 g/cm^3 and the kotlio enemy is 26.98, and the adha is over the range in silicon Adha 2.329 g/cm2.arrow_forward
- . A Geiger counter measures background radiation and records 950 counts in 10 minutes. Then the Geiger counter is brought near a radioactive source and it records 1430 counts in 10 minutes. Compute R,, the rate (in counts/min) due to the source only. Also compute &R,, the uncertainty in the rate due to the source only . Suppose in this experiment, the penetration depth in lead is 9.4 mm (whicharrow_forward3arrow_forwardA cancerous tumour is exposed to an a-emitter with an RBE of 16. What absorbed dose, in Gy, is needed to give the tumour an effective dose of 64 Sv? Report your final answer rounded to two significant digits. Your Answer: Answer unitsarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Modern PhysicsPhysicsISBN:9781111794378Author:Raymond A. Serway, Clement J. Moses, Curt A. MoyerPublisher:Cengage LearningPrinciples of Physics: A Calculus-Based TextPhysicsISBN:9781133104261Author:Raymond A. Serway, John W. JewettPublisher:Cengage LearningCollege PhysicsPhysicsISBN:9781938168000Author:Paul Peter Urone, Roger HinrichsPublisher:OpenStax College
Modern Physics
Physics
ISBN:9781111794378
Author:Raymond A. Serway, Clement J. Moses, Curt A. Moyer
Publisher:Cengage Learning
Principles of Physics: A Calculus-Based Text
Physics
ISBN:9781133104261
Author:Raymond A. Serway, John W. Jewett
Publisher:Cengage Learning
College Physics
Physics
ISBN:9781938168000
Author:Paul Peter Urone, Roger Hinrichs
Publisher:OpenStax College