Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 30, Problem 30.4QAP
Interpretation Introduction
Interpretation:
The principle of separation by CZE is to be stated.
Concept introduction:
The capillary zone electrophoresis is a type of electrophoresis in which separation of buffer solution takes place because of electrosoomotic flow. The buffer solution remains constant throughout the separation process. The rate of electrosoomotic flow controls the rate of migrating particles. The ionic compounds are easily separated by this method. The separation solution depends on the physical characteristics of the compound such as hydrodynamic radius, charge and ionic force of ions.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Q3.
A cellulose coating that weighs at least 3.00 mg is often applied to the exterior of vitamin
C tablets in order to delay the release of active ingredients. A random sampling of 100
vitamin tablets revealed that 6 vitamin tablets failed to meet the required weight of the
cellulose coating.
(а)
Calculate the relative standard deviation (in %).
(b)
Determine the number of tablets should be taken into consideration to ensure a
relative standard deviation of 15 %.
Chemistry
The amount of V was found to be 0.19% (+/-) 0.02% V (N=6). Calculate t-calc, assuming 95% confidence level.
Real life applications of standardization of NaOH.
Knowledge Booster
Similar questions
- 6arrow_forwardThe researcher extracts a sample of well water and prepares it for TXRF analysis with a 10.00 mg/L V internal standard, like the calibration standards. The result produces SCa = 69297.81 and SV = 13481.2.Determine the concentration of Ca.arrow_forwardanalyte concentration(C)(mg/ml) injection volume (ul) elution time (time) peak DAD signal(mAU) caffeine 1 1 4.67 302.85 aspartame 5 1 7.53 15.83 benzoic acid 1 1 8.14 89.98 saccharin 1 1 1.91 84.86 mixture(add everything above with 1:1:1:1 ratio) 1 4.47 69.58 How to get the concentration of the mixture in this case?arrow_forward
- (a) (i) Ksp value of Cul is 5.0 x10-12 mol2dm at 25 °C. Calculate the maximum number of moles of Cul that can be dissolved in 1 dm³ of water at 25 °C. (ii) Calculate the maximum number of moles of Cul that can be dissolved in 1 dm³ of 0.1 moldm³ of Nal solution at 25 °C.arrow_forwardPhH₂CO HO O H3O+ 1. H₂, Pd/C 2. H3O+ ethylene glycol pTSAarrow_forward2 what is the purpose of BSC Level 1 & 2, proper layout, performance, and its application in biosafety assessmentarrow_forward
- Describe the primary and secondary criteria for having achieved V ̇O2 max.arrow_forward6b. why doce CE have better performance than LC in separationarrow_forwardOnCourse Connect Assessment: Chemistry x 4 Copy of spread of islarX E The Spread of Islam- 0 x M Inbox (904) - aarojame X A Classes b oncourseconnect.com/assessment/1651879/5287e2a3-0d0b-e2c0-c15c-3e68a37149b4 TPSS Bookmarks HEMISTRY BENCHMARK TEST 01 EMISTRY I 12-7 (AARON JAMES, ID: 12390724) Some students are modeling covalent bonds with brief descriptions and Lewis dot diagrams, using arrows to show electron movement. Which model best demonstrates covalent bonding in bromine chloride (BrCI)? O: Br- . CI: Cl transfers one e to Br Brj All es from Cl and Br are shared and move freely ©: Br. CI : Br transfers one e to CI Save/Exit 3 4 5 6 8 6. 10 11 ASUSarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning