Question
Book Icon
Chapter 27, Problem 27.7QAP
Interpretation Introduction

(a)

Interpretation:

The major advantages and principle limitations of thermal conductivity detector is to be stated.

Concept introduction:

Thermal conductivity can be defined as the ability of a material to conduct heat.

Interpretation Introduction

(b)

Interpretation:

The major advantages and principle limitations of atomic emission detector is to be stated.

Concept introduction:

Atomic emission occurs when an atom emits some specific wavelengths.

Interpretation Introduction

(c)

Interpretation:

The major advantages and principle limitations of thermionic detector is to be stated.

Concept introduction:

Thermionic emissions occur when electrons are excited from a heated source.

Interpretation Introduction

(d)

Interpretation:

The major advantages and principle limitations of the electron captive detector is to be stated.

Concept introduction:

The electron captive is the process of making unstable atoms more stable.

Interpretation Introduction

(e)

Interpretation:

The major advantages and principle limitations of flame photometric detector is to be stated.

Concept introduction:

Flame photometry is utilized for inorganic chemical analysis. It can detect the concentration of some metals like lithium, sodium, calcium and more.

Interpretation Introduction

(f)

Interpretation:

The major advantages and principle limitations of flame ionization detector is to be stated.

Concept introduction:

Flame ionization detection is a device used to measure the analyte in a gas flow.

Blurred answer
Students have asked these similar questions
Chemistry
You are developing a Ca detection method for a graphite furnace AA instrument. Your analysis of ten blank samples gives a standard deviation of 0.265 ppb. To establish your limit of detection (LOD), what concentration of Ca should be spiked into your blanks?
The following calibration data were obtained by an atomic absorption spectrophotometric (AAS) method for the determination of mercury in an herbal product. (show complete solution) 1. What is the detection limit for the method? 2. What is the limit of quantitation for the method?
Knowledge Booster
Background pattern image
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:9781285640686
Author:Skoog
Publisher:Cengage
Text book image
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Text book image
General, Organic, and Biological Chemistry
Chemistry
ISBN:9781285853918
Author:H. Stephen Stoker
Publisher:Cengage Learning
Text book image
Organic And Biological Chemistry
Chemistry
ISBN:9781305081079
Author:STOKER, H. Stephen (howard Stephen)
Publisher:Cengage Learning,