Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 27, Problem 27.3QAP
Interpretation Introduction
Interpretation:
The phenomenon of temperature programming in GC and the reason for it’s frequent use is to be stated.
Concept introduction:
In the temperature programming method, the temperature of the column is continuously raised at a predefined rate which varies as function of time. This technique is commonly used for the analysis of mixtures with a wide range of boiling points.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Volatile and semi-volatile compounds can be analyzed by GC
Can you give me a detailed step by step process of how to do this please, thank you !
The researcher extracts a sample of well water and prepares it for TXRF analysis with a 10.00 mg/L V internal standard, like the calibration standards. The result produces SCa = 69297.81 and SV = 13481.2.Determine the concentration of Ca.
Chapter 27 Solutions
Principles of Instrumental Analysis
Ch. 27 - Prob. 27.1QAPCh. 27 - Prob. 27.2QAPCh. 27 - Prob. 27.3QAPCh. 27 - Prob. 27.4QAPCh. 27 - Prob. 27.5QAPCh. 27 - Prob. 27.6QAPCh. 27 - Prob. 27.7QAPCh. 27 - Prob. 27.8QAPCh. 27 - Prob. 27.9QAPCh. 27 - What are hyphenated GC methods? Briefly describe...
Ch. 27 - Prob. 27.11QAPCh. 27 - Prob. 27.12QAPCh. 27 - Prob. 27.13QAPCh. 27 - Prob. 27.14QAPCh. 27 - Prob. 27.15QAPCh. 27 - Prob. 27.16QAPCh. 27 - Prob. 27.17QAPCh. 27 - Prob. 27.18QAPCh. 27 - Prob. 27.19QAPCh. 27 - The same polar compound is gas chromatographed on...Ch. 27 - Prob. 27.21QAPCh. 27 - Prob. 27.22QAPCh. 27 - Prob. 27.23QAPCh. 27 - Prob. 27.24QAPCh. 27 - Prob. 27.25QAPCh. 27 - Prob. 27.26QAPCh. 27 - Prob. 27.27QAPCh. 27 - Prob. 27.28QAPCh. 27 - Why is GSC not used nearly as extensively as GLC?Ch. 27 - Prob. 27.30QAP
Knowledge Booster
Similar questions
- Use E5C.1(a) to Plot the data in excel. Place two data sets on the same graph: one for temp vs. x and one for temp vs y (remember, x and y are the mole fractions and they belong on the x-axis). Don’t forget to include the boiling points of the pure substances – they are data, too. Add a trendline (polynomial, 3rd order should work) to each of the coexistence lines separately. Scale the plot appropriately and use the graph to answer the questions. Then complete E5C.1(b)arrow_forward1) 1500 kg mixture contains 15% acetone, 75% water and 10% Acetic acid by weight. a) Calculate the total mole of mixture and molar fractions of each compound. b) Calculate Average Molecular Weight of mixture. c) 2 kmol more Acetic acid is added to the mixture. What would be the mass fractions of this new mixture? (MW: Acetone= 58 g/mol Water= 18 g/mol Acetic acid= 60 g/mol)arrow_forwardQ. . CLO 1.1 Write a note on importance of analytical instruments in petroleum and petrochemical industries. Q. CLO 1.2 How do process control techniques contribute to improving product quality in industry.arrow_forward
- Answer the following questions. What is the significance of moisture content determination? What are the USP and NF official methods of determining moisture content? Give their advantages and disadvantages. What are the reasons for drying the plant material before using? Enumerate the advantages and disadvantages of the gravimetric and instrumentation method of determining moisture content of a plant material.arrow_forward2 what is the purpose of BSC Level 1 & 2, proper layout, performance, and its application in biosafety assessmentarrow_forward2. Consider the following example GC Chromatogram from a publication about aggression among Mediterranean Acrobat Ants (C. scutellaris). This particular sample was generated by rinsing hydrocarbons from ant exoskeletons. From the chromatogram, what is the minimum number of unique compunds present in the sample? What data led you to that conclusion? (Don't overthink it) 2 8000000 7000000 6000000 5000000 4000000 3000000 2000000 1000000 Counts (Abundance) 5 19 6 7 0 23.00 24.00 10 | 11 13 17 20 14 15 16 12 teel | 22 19 21 ли 25.00 26.00 27.00 Time "Example of a Gas chromatography-Mass spectrography (GS-MS) chromatogram of hydrocarbon molecules in C. scutellaris" by Filippo Frizzi, et.al, in PLoS One is licensed under CC BY 4.0arrow_forward
- When we analyze the Uniformity of Dosage Units (content uniformity) in compressed tablets during PPQ, should we use the same or different methodology and acceptance criteria as those described in respective USP monograph (905) that is used for CU evaluation of routine product batches? Please explain.arrow_forwardWork outarrow_forwardHow do you find the Ksp and solubility limit for SrSO4 given [Sr]=0.000583095 & [SO4]=0.000583095?arrow_forward
- (i) Calculate the capacity factors (k') for both compounds A and B and the selectivity factor (a) between them, commenting on the values. (ii) Calculate the resolution between A and B and comment on it. (iii) Using the peak for A, calculate the number of theoretical plates for the GC column and comment on the quality of the column.arrow_forward11carrow_forwardAbsorbance (arb.units) SA 8.3 B-Carotene Calibration Curve 2004 65,03UM 3.26 mM 5,06 nM y=(105612 Mx-0.1736 2.94 M 4304 1064 ENY 181 121 Concentration (M) 1004 5 Abserbence (arb.units) 200 0.25 300 A student creates a standard curve of B-Carotene and plots the line of best fit. They then measure the absorbance of a solution of B-Carotene with an unknown concentration. What is the concentration of the sample? You can assume they used a cuvette with a pathlength of 1 cm. 400 500 600 Wavelength (nm) YOUarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning