Interpretation Introduction
Interpretation:
The variables those affect the selectivity factor
Concept introduction:
The selectivity factor is defined as the ratio of retention factor of two species.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
TLC was used to compare the solubility of two compounds A and B in a solvent system (acetic acid, methanol, H2O). The distances that solvent has moved in the silica gel TLC was 12 cm. and for the compounds were 2 and 8 cm respectively. (a) Calculate the Rf values and which compound is more soluble and which one is more polar. (b) What are the factors affecting the Rf value
The standard curve of a biuret assay gave the equation: y=0.4193x. The absorbance for Unknown
A = 0.098 and Unknown B = 0.325. Are you equally confident in the accuracy of the protein
%D
concentrations you would calculate for samples Unknown A and Unknown B? Briefly explain your
answer.
A student researcher performed a chromatographic separation of caffeine and aspartame. The retention time for caffeine, te, was
found to be 200.8 s with a baseline peak width, we, of 16.1 s. The retention time for aspartame, ta, was 258.7 s with a baseline
peak width, wa, of 20.6 s. The retention time for the unretained solvent methanol was 44.2 s.
Calculate the average plate height, H, in micrometers for this separation, given that it was performed on a 22.1 cm long column.
H =
Calculate the resolution, R, for this separation using the widths of the peaks.
R =
88.2
R₂5N =
3.16
Calculate the resolution if the number of theoretical plates were to increase by a factor of 2.5.
3.533
Incorrect
μm
Chapter 26 Solutions
Principles of Instrumental Analysis
Ch. 26 - Prob. 26.1QAPCh. 26 - Prob. 26.2QAPCh. 26 - Prob. 26.3QAPCh. 26 - Prob. 26.4QAPCh. 26 - Prob. 26.5QAPCh. 26 - Prob. 26.6QAPCh. 26 - Prob. 26.7QAPCh. 26 - Prob. 26.8QAPCh. 26 - Prob. 26.9QAPCh. 26 - Prob. 26.10QAP
Ch. 26 - Prob. 26.11QAPCh. 26 - Prob. 26.12QAPCh. 26 - Prob. 26.13QAPCh. 26 - Prob. 26.14QAPCh. 26 - Prob. 26.15QAPCh. 26 - Prob. 26.16QAPCh. 26 - From the data in Problem 26-14, calculate for...Ch. 26 - Prob. 26.18QAPCh. 26 - Prob. 26.19QAPCh. 26 - Prob. 26.20QAPCh. 26 - Prob. 26.21QAPCh. 26 - Prob. 26.22QAPCh. 26 - Prob. 26.23QAP
Knowledge Booster
Similar questions
- 3arrow_forwardIn spectrophotometric analysis, the relationship between the absorbance A and the analyte's concentration C is: A = ebC + Ablank What is the molar extinction coefficient I and its absolute uncertainty if A is 0.68 ± 0.06; Ablank is 0.06 ± 0.01; b is 1.00 cm; and C is (0.45 ± 0.03)x10-5 mol/L?arrow_forward4c. Calculate the values of Mn, Mw, Mz and polydispersity index for a polymer mixture having equivalent moles of two polymers with exact molecular weight being 2,000 Dalton and 10,000 Dalton.arrow_forward
- Under what wavelength (in nm) should a spectrophotometer be set to be able to measure the optical density of microbial cultures? What could be viable reference blanks we can use to zero our spectrophotometer when measuring the optical density of microbial cultures?arrow_forwardA spectrophotometric method for the quantitative determination of the concentration ofPb2+ in blood yields an Ssamp of 0.133 for a 1 mL sample of blood that has been diluted to 6 mL. A second sample is spiked with 1 µL of a 1467 ppb Pb2+ standard and diluted to 6 mL, yielding an Sspike of 0.491. Determine the concentration of Pb2+ in the original sample of blood.arrow_forwardIn a Bradford assay, 11 µl of a protein isolate sample was diluted by adding 21 µl of water prior to the addition 2.0 mL Bradford reagent. Calculate the protein concentration (in mg/mL) of the original protein isolate sample whose absorbance reading at 595 nm is 0.304 after dilution. The protein standard solutions used for the calibration curve of the Bradford assay was constructed using bovine serum albumin (BSA) stock solution whose concentration is 200 µg/mL. The concentration and the corresponding absorbance reading at 595 nm of the protein standard solutions are summarized in the table below: Standard soln # 1 2 13 4 6 conc of BSA 12.00 24.00 36.00 48.00 60.00 (pg/mL) Absorbance at 595 nm 0.000 0.156 0.249 0.328 0.411 0.528 zNote: Final answer format must be x.xxx (three decimal places). Round off only in the final answer. Do not round off in the middle of the calculation.arrow_forward
- In color chromatography of plant pigments, what complications would a dried-out column (solvent level is below the top of the silica) introduce to the elution and isolation of pigments?arrow_forwardDoes KMNO4 oxidize or reduce an analyte during permanganimetry?arrow_forwardGive examples of two aspects of the mobile phase a chemist can manipulate to affect the RF of analytes.arrow_forward
- An acidic solute, HA, has a K₁ of 1.00 X 10-5 and a partition coefficient, Kp, between water and hexane of 5.00. Calculate the extraction efficiency if we extract a 50.00 mL sample of a 0.025 M aqueous solution of HA, buffered to a pH of 8.00, with 100.00 mL of hexane.arrow_forwardA method for the analysis of Ca2+ in water suffers from an interference in the presence of Zn2+. When the concentration of Ca2+ is 100 times greater than that of Zn2+, an analysis for Ca2+ gives a relative error of +0.5%. What is the selectivity coefficient for this method?arrow_forward7 How is the variation in sample composition in a powder random mix influenced by the proportion of active ingredient particles and by the total number of particles in the sample?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning