Question
thumb_up100%
Chapter 26, Problem 26.18QAP
Interpretation Introduction
(a)
Interpretation:
Average number of plates should be calculated.
Concept introduction:
Number of theoretical plates is given by following equation:
N = number of plates
tR = retention time
W = width of peak base
Average =
Interpretation Introduction
(b)
Interpretation:
Standard deviation for the N should be calculated.
Concept introduction:
Standard deviation will give how the values deviate from mean value of N.
Interpretation Introduction
(c)
Interpretation:
Average plate height of column should be calculated.
Concept introduction:
N = plate count
L = length of the packing (cm)
H = height of the column
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
4.Consider the peaks for pentafluorobenzene and benzene in the gas chromatogram shown here. The elution time for unretained solute is 1.06 min. The open tubular column is 30.0 m in length and 0.530 mm in diameter, with a layer of stationary phase 3.0 μm thick on the inner wall.
a) Measruing the width, w, at the baseline on the chromatogram, find the number of plates for these two compounds
b) Use your answer to (a) to find the resolution between the two peaks
c) Using the number of plates N=sqrtN1*N2 with the values from (a) calcuate what the resolution should be and compare your answer with the measured resolution in b
Waooo hiiiii
(a) In High Performance Liquid Chromatography (HPLC), the separation method is by
partition of the solute (analyte) between the mobile phase and the stationary phase.
Explain how this leads to separation of analyte mixtures;
(b) Describe the structure and materials use in a typical column used for HPLC. Thereby
explain why high pressures have to be used in HPLC;
(c) Discuss how the need for high pressures also imposes requirements on the injector;
Chapter 26 Solutions
Principles of Instrumental Analysis
Ch. 26 - Prob. 26.1QAPCh. 26 - Prob. 26.2QAPCh. 26 - Prob. 26.3QAPCh. 26 - Prob. 26.4QAPCh. 26 - Prob. 26.5QAPCh. 26 - Prob. 26.6QAPCh. 26 - Prob. 26.7QAPCh. 26 - Prob. 26.8QAPCh. 26 - Prob. 26.9QAPCh. 26 - Prob. 26.10QAP
Ch. 26 - Prob. 26.11QAPCh. 26 - Prob. 26.12QAPCh. 26 - Prob. 26.13QAPCh. 26 - Prob. 26.14QAPCh. 26 - Prob. 26.15QAPCh. 26 - Prob. 26.16QAPCh. 26 - From the data in Problem 26-14, calculate for...Ch. 26 - Prob. 26.18QAPCh. 26 - Prob. 26.19QAPCh. 26 - Prob. 26.20QAPCh. 26 - Prob. 26.21QAPCh. 26 - Prob. 26.22QAPCh. 26 - Prob. 26.23QAP
Knowledge Booster
Similar questions
- The height of three peaks; A, B, and C obtained in a gas chromatogram are 20.6 mm, 17.5 mm and 40.6 mm. The width of the peaks, at half height, are 4.4 mm, 4.0 mm and 3.9 mm, respectively. Calculate the percentage composition of A in the sample.arrow_forwardA young researcher was evaluating a standard method for determining the methylmercury content in blue fin tuna using high performance liquid chromatography (HPLC). She determined the standard deviation (?)(s) for the method to be 0.440.44 ppb and assumed that ?s was a good approximation of ?σ . As a test, she used this method to evaluate the methylmercury content in a National Institutes of Standards and Technology (NIST) standard and determined the unknown amount to be within 0.210.21 ppb (?)(μ) of the known mean with 99% probability. How many replicate measurements of the NIST standard did the researcher perform?arrow_forwardReplicate tests showed the following lead content results of a blood sample: 0.752, 0.756, 0.752, 0.751, and 0.760 ppm Pb. Calculate the (a) the mean (b) the standard deviation (c) the variance (d) the relative standard deviation in parts per thousand, (e) the coefficient of variation, and (f) the spread.arrow_forward
- The following results were obtained for the determination of calcium in a NIST limestone sample: %CaO = 50.33, 50.22, 50.36, 50.21, and 50.44. Five gross samples were then obtained for a carload of limestone. The average %CaO values for the gross samples were found to be 49.53, 50.12, 49.60, 49.87, and 50.49. Calculate the relative standard deviation associated with the sampling steparrow_forward1. From spinach, the chromatographic analysis will yield two major substances: (a) B-carotene (C40H56), which will separate from the spinach mixture to form a yellow band, and (b) chlorophyll A (CSSH72MGN4OS), which will separate from the mixture to form a green band. i. Describe the characteristics and draw structures of these molecules. ii. From the spectrophotometric analysis, what wavelength (Amax) would you expect ß-carotene (C40H56) to absorb? What wavelength would chlorophyll A (CssH72MgN4O5) absorb?arrow_forwardA molecular exclusion column has a diameter of 7.8 mm and a length of 30 cm. The solid portion of the particles occupies 20% of the volume, the pores occupy 40%, and the volume between particles occupies 40%. (a) At what volume would totally excluded molecules be expected to emerge? (b) At what volume would the smallest molecules be expected? (c) A mixture of polymers of various molecular masses is eluted between 23 and 27 mL. What does this imply about the retention mechanism for these solutes on the column?arrow_forward
- The following results were obtained for the determination of calcium in a NIST limestone sample: % CaO = 50.32, 50.22, 50.40, 50.21, and 50.44. Five gross samples were then obtained for a carload of limestone. The average percent CaO values for the gross samples were found to be 49.47, 50.10, 49.58, 49.76, and 50.49. Calculate the relative standard deviation associated with the sampling step. Relative standard deviation =arrow_forwardIn stationary chromatography, the distribution (K) is the main criterion for the division of species in the sample between the two functions of the system, which factors depend onarrow_forwardYou are developing a Ca detection method for a graphite furnace AA instrument. Your analysis of ten blank samples gives a standard deviation of 0.265 ppb. To establish your limit of detection (LOD), what concentration of Ca should be spiked into your blanks?arrow_forward
- The results in the table below were obtained from the analyses of Mg2+ content in an orange juice sample using a flame-AAS. Based on these results answer the following questions: (i) (ii) Replicate 1 2 3 4 Mg²+(ppm) 7.08 7.21 7.12 7.09 Calculate the mean, standard deviation and coefficient of variation (or %RSD) for the results obtained. If the certified value of the Mg2+ content of the apple juice sample is 7.45 ppm. What is the percentage of recovery for this analysis?arrow_forwardAnalysis of an unknown plant extract yield two peaks X and Y in a chromatogram, 15.65 and 17.03 min respectively in a 30.0 cm column. The peak base width for X is 1.06 and 1.15 for Y. The average number of plates in the column isarrow_forward3. Seven analyses for the phosphorus content of a fertilizer resulted in 16.2, 17.5, 15.4, 15.9, 16.8, 16.3, and 17.1%. Find (a) the standard deviation, s, , and (b) the 95% confidence interval for the true value, H. 4. The following five values were obtained for the wt % of an organic acid in a sample: 30.3, 31.1, 32.6, 36.7, 28.9. Determine if the value of 36.7 may be rejected at the 90% (two-tailed) confidence level. 5. The concentration of a NaOH solution is determined in a single experiment by titrating a weighed sample of pure, dried KHP (MW = 204.229) with the NaOH. The data are: Weight of KHP = (11.6723 + 0.0001) - (10.8364 ±0.0001) g Volume NaOH = (32.68 + 0.02) - (1.24 + 0.02) mL Where the standard deviations are o, values. (a) What is the molarity of the NaOH? (b) Based on the propagation-of-error formula, what is the standard deviation of the molarity,oM ?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning